| Process Sealed Miniature Rockers Series M2 | Process Sealed Miniature Rockers Series M2 Distinctive Characteristics Antijamming design protects against mechanism damage from downward force on the actuator. O-ring surrounding top of lever prevents liquids from reaching switch mechanism. Ultrasonic welding of upper and lower housing |
Original | ||||
| Process Sealed Miniature Rockers Series M2 | Process Sealed Miniature Rockers Series M2 Distinctive Characteristics Antijamming design protects against mechanism damage from downward force on the actuator. O-ring surrounding top of lever prevents liquids from reaching switch mechanism. Ultrasonic welding of upper and lower housing |
Original | ||||
| Process Sealed Miniature Rockers Series M2 | Process Sealed Miniature Rockers Series M2 Distinctive Characteristics Antijamming design protects against mechanism damage from downward force on the actuator. O-ring surrounding top of lever prevents liquids from reaching switch mechanism. Ultrasonic welding of upper and lower housing |
Original | ||||
| multi-junction cell | MULTI-JUNCTION CELLS WITH MONOLITIC BYPASS DIODES P. R. Sharps, M. A. Stan, D. J. Aiken, B. Clevenger, J. S. Hills, and N. S. Fatemi EMCORE Photovoltaics 10420 Research Rd. SE Albuquerque, NM 87123 USA ABSTRACT Bypass diodes are attached electrically parallel (but with |
Original | ||||
| KR series New! Power rocker switches Distinctive | KR series New! Power rocker switches Distinctive features UG1006-A Attractive rugged rocker switch Removable actuator Up-to-date rocker design Easy to stock Easy to customize Smooth curves Wide choice of colours and symbols Laser etched symbols on illuminated versions |
Original | ||||
| 10-Serie KR-A _08-Serie KG-A 21/11/12 17:47 | 10-Serie KR-A _08-Serie KG-A 21/11/12 17:47 Page53 KR series Power rocker switches Distinctive features Attractive rugged rocker switch Removable actuator Up-to-date rocker design Easy to stock Easy to customize Smooth curves Wide choice of colours and symbols |
Original | ||||
| A Allied Controls Incorporated Series S Military | A Allied Controls Incorporated Series S Military Relay Initial Contact Resistance: 0.05 ohms maximum Insulation Resistance: 1000 megohms minimum Contact Arrangements: 2 form C Contact Ratings: Low level Non-inductive: 2 amp @ 28VDC 0.3 amp @ 115VAC, 60 to 400Hz |
OCR Scan | ||||
| engineering reference | Fujitsu Components Engineering Reference Relays Fujitsu Components International Headquarter Offices Japan Fujitsu Component Limited Gotanda-Chuo Building 3-5, Higashigotanda 2-chome, Shinagawa-ku Tokyo 141, Japan Tel: (81-3) 5449-7010 Fax: (81-3) 5449-2626 |
Original | ||||
| l2x-800 | 1 L2X-800 SERIES Magnasphere has created NEW L2X-800 ‘High Security 2 Sensor” -The Next Generation Sensors That Meet UL634 Level 2 High Security Standards for SCIFs. Safes, Vaults and Hazardous Environment Applications ULI HIGH SECURITY LEVEL 2 CUL HIGH SECURITY |
Original | ||||
| takamisawa | FUJITSU TAKAMISAWA COMPONENT CATALOG HIGH POWER RELAY 1 POLE—40 A (FOR AUTOMOTIVE APPLICATIONS) FRL-274 (40A TYPE) SERIES ■ FEATURES ● High current switching and carry by using new conductive materials. Suitable for automotive applications such as ABS, power |
Original | ||||
| APPLICATION NOTE LATCHING CURRENT By E. LEBLANC | APPLICATION NOTE LATCHING CURRENT By E. LEBLANC An important problem concerning the utilization of components such as thyristors or triacs is the holding of the component in the conducting state after the trigger current has disappeared during firing. |
Original | ||||
| 270/275 Series DC Deltrol CONTROLS 270/275 Series | 270/275 Series DC Deltrol CONTROLS 270/275 Series 35 Amp Power Relay General purpose relay that controls electrical loads Features • 35 Amps switching on all contacts thru a DPDT configuration (25 Amps in Europe) • Coil Molded in Dupont Rynite® PET, providing Class F Temperature |
Original | ||||
| an303 application | AN303 APPLICATION NOTE LATCHING CURRENT INTRODUCTION An important problem concerning the utilization of components such as thyristors or triacs is the holding of the component in the conducting state after the trigger current has disappeared during firing. |
Original | ||||
| Data Pack A Data Sheet Issued July 1997 249-5062 | Data Pack A Data Sheet Issued July 1997 249-5062 Computer Aided Design (CAD) software Computer Aided Design (CAD) Software ● Eight light sources for more realistic shading of objects. Introduction ● Custom shading and colour palettes. ● Able to import and export DXF files. |
Original | ||||
|
|
||||||
| ftr-k2w | FTR-K1 SERIES POWER RELAY 1 POLE - 30A DC Relay 2 x 3.2mm contact gap FTR-K2W Series n FEATURES Contact rating: 60VDC, 30A; 72VDC, 25A Wide contact gap: 2 x 3.2mm l Compact size: 36.5 (L) x 34.9 (W) x 30.2 (H) mm l 1 form A contact l High insulation (between coil and contact) |
Original | ||||
| takamisawa | FUJITSU TAKAMISAWA COMPONENT CATALOG HIGH POWER RELAY 1 POLE—30 A (FOR AUTOMOTIVE APPLICATIONS) FRL-274 SERIES ■ FEATURES ● Maximum switching current 30 A Three types of contact gaps (0.4 mm, 1.0 mm, 1.4 mm) Various contact materials |
Original | ||||
| frl-274 | HIGH POWER RELAY 1 POLE—30 A (FOR AUTOMOTIVE APPLICATIONS) FRL-274 SERIES ■ FEATURES ● Maximum switching current 30 A Three types of contact gaps (0.4 mm, 1.0 mm, 1.4 mm) Various contact materials Immersion cleanable type available Tube carrier package |
Original | ||||
| frl-274 | HIGH POWER RELAY 1 POLE—12, 30, 40 A (FOR AUTOMOTIVE APPLICATIONS) FRL-274 SERIES ■ FEATURES ● High current switching and carry by using new conductive materials. Suitable for automotive applications such as ABS, power assisted steering,etc. |
Original | ||||
| Process Sealed Miniature Pushbuttons Series M2 | Process Sealed Miniature Pushbuttons Series M2 Distinctive Characteristics Snap-acting contact mechanism gives short travel, sensitive actuation, light touch, smooth feel, audible feedback, and a longer electrical life. Single unit construction of the bushing and top of the |
Original | ||||