Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    WATER LEVEL SENSOR FOR Search Results

    WATER LEVEL SENSOR FOR Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    SF-SFP28LPB1W-0DB
    Amphenol Cables on Demand Amphenol SF-SFP28LPB1W-0DB SFP28 Loopback Adapter Module for SFP28 Port Compliance Testing - 0dB Attenuation & 1W Power Consumption PDF
    SF-SFPPLOOPBK-0DB
    Amphenol Cables on Demand Amphenol SF-SFPPLOOPBK-0DB SFP+ Loopback Adapter Module for SFP+ Port Compliance Testing - 0dB Attenuation & 0W Power Consumption PDF
    SF-SFPPLOOPBK-003.5
    Amphenol Cables on Demand Amphenol SF-SFPPLOOPBK-003.5 SFP+ Loopback Adapter Module for SFP+ Port Compliance Testing - 3.5dB Copper/Optical Cable Emulation PDF
    SF-SFP28LPB1W-3DB
    Amphenol Cables on Demand Amphenol SF-SFP28LPB1W-3DB SFP28 Loopback Adapter Module for SFP28 Port Compliance Testing - 3dB Attenuation & 1W Power Consumption PDF
    SF-100GLB1.5W-6DB
    Amphenol Cables on Demand Amphenol SF-100GLB1.5W-6DB QSFP 100G Loopback Adapter Module for QSFP28 Port Testing - 6dB Attenuation & 1.5W Power Consumption [100-Gigabit Ethernet Ready] PDF

    Documents mentioning WATER LEVEL SENSOR FOR

    Document Partial File Text Tags Type PDF
    pn-12110215tc-12
    Continuous Fluid Level Sensor PN-12110215TC-12 eTape TM Description The eTape sensor is a solid state, continuous (multi-level) fluid level sensor for measuring levels in water, non-corrosive water based liquids and dry fluids (powders). The eTape sensor is
    Original PDF
    water level sensor
    SIMPLECIRCUIT™ Water Level Sensor for Bathtub, Jaccuzi, or Pool Author: FIGURE 1: Dan Janicik DK Technologies, Inc. Inwin, PA USA BLOCK DIAGRAM water source valve INTRODUCTION The system monitors the water level using a PIC12C67X. As water flows into the tub, the sensor
    Original PDF
    MOTOROLA SEMICONDUCTOR APPLICATION NOTE AN1950
    MOTOROLA SEMICONDUCTOR APPLICATION NOTE AN1950 Water Level Monitoring By Michelle Clifford Applications Engineer Sensor Products Division Tempe, AZ INTRODUCTION Many washing machines that are currently in production use a mechanical sensor for water level detection.
    Original PDF
    an1950
    Freescale Semiconductor Application Note AN1950 Rev 3, 11/2004 Water Level Monitoring by: Michelle Clifford, Applications Engineer Sensor Products, Tempe, AZ INTRODUCTION Many washing machines currently in production use a mechanical sensor for water level detection.
    Original PDF
    an1950
    Freescale Semiconductor Application Note AN1950 Rev 4, 11/2006 Water Level Monitoring by: Michelle Clifford, Applications Engineer Sensor Products, Tempe, AZ INTRODUCTION Many washing machines currently in production use a mechanical sensor for water level detection. Mechanical
    Original PDF
    capacitive
    Level Sensors Capacitive Level Detector Type CD50 DC • Basic capacitive water level sensor For water storage tanks in mini-pools and whirlpools Detection of excess water in the whirlpool tub Safety device to control the operation of the pump.
    Original PDF
    pressure sensor
    PS-A (ADPW) Pressure sensor Built-in amplifier and compensating circuit New PS-A PRESSURE SENSOR Direct water pressure detection type FEATURES TYPICAL APPLICATIONS 1. Not only air, now water pressure can be detected directly. • Water heaters (water level detection)
    Original PDF
    PS-A (ADPW) Pressure sensor Built-in amplifier
    PS-A (ADPW) Pressure sensor Built-in amplifier and compensating circuit New PS-A PRESSURE SENSOR Direct water pressure detection type FEATURES TYPICAL APPLICATIONS • Not only air, now water pressure can be detected directly. • Water heaters (water level detection)
    Original PDF
    PS-A (ADPW) Pressure sensor Built-in amplifier
    PS-A (ADPW) Pressure sensor Built-in amplifier and compensating circuit New PS-A PRESSURE SENSOR Direct water pressure detection type FEATURES TYPICAL APPLICATIONS 1. Not only air, now water pressure can be detected directly. • Water heaters (water level detection)
    Original PDF
    PS-A (ADPW) Pressure sensor Built-in amplifier
    PS-A (ADPW) Pressure sensor Built-in amplifier and compensating circuit New PS-A PRESSURE SENSOR Direct water pressure detection type FEATURES TYPICAL APPLICATIONS 1. Not only air, now water pressure can be detected directly. • Water heaters (water level detection)
    Original PDF
    ls03
    LS03 Series MEDER electronic Level Sensors with Magnetic Floats DESCRIPTION Standard liquid level sensor. The sensor has to be mounted horizontally for best results. Following materials are available: PP (Polypropylene) for water applications and dilute acids
    Original PDF
    ls02
    Meder Electronic LS02 Series Level Sensors with Magnetic Floats DESCRIPTION Standard liquid level sensor. The sensor has to be mounted vertically for best results. Two versions are available: APPLICATIONS PP (Polypropylene) for water applications and dilute acids
    Original PDF
    ls02
    MEDER electronic LS02 Series Level Sensors with Magnetic Floats DESCRIPTION Standard liquid level sensor. The sensor has to be mounted vertically for best results. Two versions are available: APPLICATIONS PP (Polypropylene) for water applications and dilute acids
    Original PDF
    ls03
    MEDER electronic LS03 Series Level Sensors with Magnetic Floats DESCRIPTION Standard liquid level sensor. The sensor has to be mounted horizontally for best results. Two versions are available: APPLICATIONS PP (Polypropylene) for water applications and dilute acids
    Original PDF
    ls03
    Meder Electronic LS03 Series Level Sensors with Magnetic Floats DESCRIPTION Standard liquid level sensor. The sensor has to be mounted horizontally for best results. Two versions are available: APPLICATIONS PP (Polypropylene) for water applications and dilute acids
    Original PDF
    ls02
    MEDER electronic LS02 Series Level Sensors with Magnetic Floats DESCRIPTION Standard liquid level sensor. The sensor has to be mounted vertically for best results. APPLICATIONS Two versions are available: PP (Polypropylene) for water applications and dilute acids
    Original PDF
    ls02
    MEDER electronic LS02 Series Level Sensors with Magnetic Floats DESCRIPTION Standard liquid level sensor. The sensor has to be mounted vertically for best results. Two versions are available: APPLICATIONS PP (Polypropylene) for water applications and dilute acids
    Original PDF
    water level sensor
    FPOW Data sheet Unit/Water level sensor Features… Applications . Boiler Positive and negative water pressure measurable . Industrial instrumentation Volt level output Piggy-back style, pre-amplified and pre-compensated module Pre-calibration of offset voltage and span
    Original PDF
    water level sensor
    FPW Data sheet Unit/Water level sensor Features… Applications . Boiler Positive and negative water pressure measurable . Industrial instrumentation Volt level output Piggy-back style, pre-amplified and pre-compensated module Pre-calibration of offset voltage and span
    Original PDF
    lmt100
    Level sensors LMT100 Electronic level sensor LMT Connector Process connection: G½ gold-plated contacts 2 switching outputs normally open / closed complementary 1: tightening torque 20…25 Nm Made in Germany Application water, water-based medium Electrical design
    Original PDF
    level sensor
    Level Sensor NR 80 Description Level Sensor NR 80 is designed to monitor a preset medium level in electrically non-conductive containers with a wall thickness up to approx. 5 mm. It is fitted outside the container. Suitable for water and other electrically conductive liquids with a high
    Original PDF
    ls01
    MEDER electronic LS01 Series Level Sensors with Magnetic Floats DESCRIPTION Standard liquid level sensor. The sensor has to be mounted vertically for best results. Two versions are available: PP (Polypropylene) for water applications and dilute acids PA (Polyamide) for use in oil, gasoline (petrol) and
    Original PDF