Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    WATER LEVEL MONITO Search Results

    WATER LEVEL MONITO Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    TC7MP3125FT
    Toshiba Electronic Devices & Storage Corporation Level shifter, Bidirectional, 2-Bit x 2 Dual Supply Bus Transceiver, TSSOP16B, -40 to 85 degC Datasheet
    74LV4T126FK
    Toshiba Electronic Devices & Storage Corporation Level shifter, Unidirectional, 1-Bit x 4 Single Supply Bus Buffer, US14, -40 to 125 degC Datasheet
    74LV4T125FK
    Toshiba Electronic Devices & Storage Corporation Level shifter, Unidirectional, 1-Bit x 4 Single Supply Bus Buffer, US14, -40 to 125 degC Datasheet
    7UL1T04NX
    Toshiba Electronic Devices & Storage Corporation One-Gate Logic(L-MOS), Inverter with Level Shifting, XSON6, -40 to 125 degC Datasheet
    74LV4T126FT
    Toshiba Electronic Devices & Storage Corporation Level shifter, Unidirectional, 1-Bit x 4 Single Supply Bus Buffer, TSSOP14, -40 to 125 degC, AEC-Q100 Datasheet

    Documents mentioning WATER LEVEL MONITO

    Document Partial File Text Tags Type PDF
    water level sensor
    SIMPLECIRCUIT™ Water Level Sensor for Bathtub, Jaccuzi, or Pool Author: FIGURE 1: Dan Janicik DK Technologies, Inc. Inwin, PA USA BLOCK DIAGRAM water source valve INTRODUCTION The system monitors the water level using a PIC12C67X. As water flows into the tub, the sensor
    Original PDF
    MOTOROLA SEMICONDUCTOR APPLICATION NOTE AN1950
    MOTOROLA SEMICONDUCTOR APPLICATION NOTE AN1950 Water Level Monitoring By Michelle Clifford Applications Engineer Sensor Products Division Tempe, AZ INTRODUCTION Many washing machines that are currently in production use a mechanical sensor for water level detection.
    Original PDF
    an1950
    Freescale Semiconductor Application Note AN1950 Rev 3, 11/2004 Water Level Monitoring by: Michelle Clifford, Applications Engineer Sensor Products, Tempe, AZ INTRODUCTION Many washing machines currently in production use a mechanical sensor for water level detection.
    Original PDF
    an1950
    Freescale Semiconductor Application Note AN1950 Rev 4, 11/2006 Water Level Monitoring by: Michelle Clifford, Applications Engineer Sensor Products, Tempe, AZ INTRODUCTION Many washing machines currently in production use a mechanical sensor for water level detection. Mechanical
    Original PDF
    pressure sensor
    PS-A (ADPW) Pressure sensor Built-in amplifier and compensating circuit New PS-A PRESSURE SENSOR Direct water pressure detection type FEATURES TYPICAL APPLICATIONS 1. Not only air, now water pressure can be detected directly. • Water heaters (water level detection)
    Original PDF
    PS-A (ADPW) Pressure sensor Built-in amplifier
    PS-A (ADPW) Pressure sensor Built-in amplifier and compensating circuit New PS-A PRESSURE SENSOR Direct water pressure detection type FEATURES TYPICAL APPLICATIONS • Not only air, now water pressure can be detected directly. • Water heaters (water level detection)
    Original PDF
    PS-A (ADPW) Pressure sensor Built-in amplifier
    PS-A (ADPW) Pressure sensor Built-in amplifier and compensating circuit New PS-A PRESSURE SENSOR Direct water pressure detection type FEATURES TYPICAL APPLICATIONS 1. Not only air, now water pressure can be detected directly. • Water heaters (water level detection)
    Original PDF
    PS-A (ADPW) Pressure sensor Built-in amplifier
    PS-A (ADPW) Pressure sensor Built-in amplifier and compensating circuit New PS-A PRESSURE SENSOR Direct water pressure detection type FEATURES TYPICAL APPLICATIONS 1. Not only air, now water pressure can be detected directly. • Water heaters (water level detection)
    Original PDF
    level sensor
    Level Sensor NR 80 Description Level Sensor NR 80 is designed to monitor a preset medium level in electrically non-conductive containers with a wall thickness up to approx. 5 mm. It is fitted outside the container. Suitable for water and other electrically conductive liquids with a high
    Original PDF
    ls03
    LS03 Series MEDER electronic Level Sensors with Magnetic Floats DESCRIPTION Standard liquid level sensor. The sensor has to be mounted horizontally for best results. Following materials are available: PP (Polypropylene) for water applications and dilute acids
    Original PDF
    ls02
    Meder Electronic LS02 Series Level Sensors with Magnetic Floats DESCRIPTION Standard liquid level sensor. The sensor has to be mounted vertically for best results. Two versions are available: APPLICATIONS PP (Polypropylene) for water applications and dilute acids
    Original PDF
    ls02
    MEDER electronic LS02 Series Level Sensors with Magnetic Floats DESCRIPTION Standard liquid level sensor. The sensor has to be mounted vertically for best results. Two versions are available: APPLICATIONS PP (Polypropylene) for water applications and dilute acids
    Original PDF
    ls03
    MEDER electronic LS03 Series Level Sensors with Magnetic Floats DESCRIPTION Standard liquid level sensor. The sensor has to be mounted horizontally for best results. Two versions are available: APPLICATIONS PP (Polypropylene) for water applications and dilute acids
    Original PDF
    ls03
    Meder Electronic LS03 Series Level Sensors with Magnetic Floats DESCRIPTION Standard liquid level sensor. The sensor has to be mounted horizontally for best results. Two versions are available: APPLICATIONS PP (Polypropylene) for water applications and dilute acids
    Original PDF
    px430-trap
    SUBMERSIBLE WATER LEVEL TRANSMITTERS MEASURE 0-1.5 m (5 FT) TO 0-210.3 m (690 FT) OF WATER PX430-TRAP included with all models MADE IN USA ߜ Designed for Complete Submersibility ߜ Welded 316 Stainless Steel Construction ߜ Unique Cable Seal System Insures WaterTight Integrity
    Original PDF
    LevelSensorNR80 Description Level Sensor NR 80 is
    LevelSensorNR80 Description Level Sensor NR 80 is designed to monitor a preset medium level in electrically non-conductive containers with a wall thickness up to approx. 5 mm. It is fitted outside the container. Suitable for water and other electrically conductive liquids with a high
    Original PDF
    ls02
    MEDER electronic LS02 Series Level Sensors with Magnetic Floats DESCRIPTION Standard liquid level sensor. The sensor has to be mounted vertically for best results. APPLICATIONS Two versions are available: PP (Polypropylene) for water applications and dilute acids
    Original PDF
    Floatless Level Controller 61F Automatic Water
    Floatless Level Controller 61F Automatic Water Supply and Drainage Control • Ideal for level control of any conductive liquid • Both general-purpose and panel-use models available • Incorporates an arrester for surge and induced lightning protection
    Original PDF
    ls02
    MEDER electronic LS02 Series Level Sensors with Magnetic Floats DESCRIPTION Standard liquid level sensor. The sensor has to be mounted vertically for best results. Two versions are available: APPLICATIONS PP (Polypropylene) for water applications and dilute acids
    Original PDF
    rsf20
    RSF20 low level switch for boiling water TM The RSF20 is designed to eliminate the problems associated with limescale build up around the pivot point on a conventional float switch. Low level switch position This particular series is primarily for applications where a low level condition has to
    Original PDF