VOLTAGE MONITORING RELAY Search Results
VOLTAGE MONITORING RELAY Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| DF2B20M4SL | Toshiba Electronic Devices & Storage Corporation | TVS Diode (ESD Protection Diode), Bidirectional, +/-18.5 V, SOD-962 (SL2) | Datasheet | ||
| DF2B6M4ASL | Toshiba Electronic Devices & Storage Corporation | TVS Diode (ESD Protection Diode), Bidirectional, +/-5.5 V, SOD-962 (SL2) | Datasheet | ||
| DF2B7BSL | Toshiba Electronic Devices & Storage Corporation | TVS Diode (ESD Protection Diode), Bidirectional, +/-5.5 V, SOD-962 (SL2) | Datasheet | ||
| DF2B7ASL | Toshiba Electronic Devices & Storage Corporation | TVS Diode (ESD Protection Diode), Bidirectional, +/-5.5 V, SOD-962 (SL2) | Datasheet | ||
| DF2S6P2FU | Toshiba Electronic Devices & Storage Corporation | TVS Diode (ESD Protection Diode), Unidirectional, 5.5 V, SOD-323 (USC) | Datasheet |
Documents mentioning VOLTAGE MONITORING RELAY
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| phase sequence | Electronic monitoring relays PMDsrange Phase sequence monitoring S1PN Unit features ` ` ` ` ` ` Measuring voltage up to 690 VAC Phase sequence monitoring Phase failure monitoring Fuse monitoring LEDs Extensive voltage range Altdaten CMT Altdaten CMT The S1PN phase sequence monitoring |
Original | ||||
| K3PF400VSY02 Monitoring relays - KAPPA series | K3PF400VSY02 Monitoring relays - KAPPA series Voltage monitoring in 3-phase mains Monitoring of phase sequence and phase failure Monitoring of asymmetry Optional connection of neutral wire Supply voltage = measuring voltage 2 change over contacts Plug-in housing |
Original | ||||
| phase sequence | E1PF Monitoring relays - ENYA series Voltage monitoring in 3-phase mains Monitoring of phase sequence and phase failure Monitoring of asymmetry Connection of neutral wire optional Supply voltage = measuring voltage 1 change over contact Width 17.5mm Installation design |
Original | ||||
| phase failure | E3PF Monitoring relays - ENYA series Voltage monitoring in 3-phase mains Monitoring of phase sequence and phase failure Monitoring of asymmetry Connection of neutral wire optional Supply voltage = measuring voltage 2 change over contacts Width 35 mm Installation design |
Original | ||||
| E1PF Monitoring relays - ENYA series Voltage | E1PF Monitoring relays - ENYA series Voltage monitoring in 3-phase mains Monitoring of phase sequence and phase failure Monitoring of asymmetry Connection of neutral wire optional Supply voltage = measuring voltage 1 change over contact Width 17.5 mm Installation design |
Original | ||||
| G2PW…10 Monitoring relays - GAMMA series Voltage | G2PW…10 Monitoring relays - GAMMA series Voltage monitoring in 3-phase mains Windowfunction Supply voltage selectable via power modules 1 change-over contact Width 22.5mm Industrial design Technical data 1. Functions Voltage monitoring in 3-phase mains monitoring the window between |
Original | ||||
| E1YF, E1YU Monitoring relays - ENYA series | E1YF, E1YU Monitoring relays - ENYA series Voltage monitoring in 3-phase mains Undervoltage monitoring Supply voltage = measured voltage 1 change over contact Width 17.5 mm Installation design Technical data 1. Functions Switching frequency: Undervoltage monitoring in 3-phase mains (each phase against the |
Original | ||||
| Monitoring modules Monitoring Modules SMSU 24 R | Monitoring modules Monitoring Modules SMSU 24 R SMSU 48 R Single-phase voltage monitoring units Voltage Monitors with adjustable switching threshold Voltage monitoring units for single-phase (18V…260V) and three-phase monitoring. Operating status is indicated by an LED, |
OCR Scan | ||||
| g2uw300v10 | G2UW300V10 Monitoring relays - GAMMA series AC/DC voltage monitoring in 1-phase mains Windowfunction Supply voltage selectable via power modules 1 change-over contact Width 22.5mm Industrial design Technical data 1. Functions Switching frequency: AC/DC voltage monitoring in 1-phase mains monitoring the window |
Original | ||||
| Electronic Monitoring Relays Single-phase voltage | Electronic Monitoring Relays Single-phase voltage monitoring ZUZ S Technical Details Electrical data Measuring voltage = supply voltage Tolerance Power consumption Switching capability in accordance with EN 60947-4-1, 10/91 The electronic AC voltage monitoring |
Original | ||||
| sy20 | G2PM…SY20 Monitoring relays - GAMMA series Voltage monitoring in 3-phase mains Multifunction Monitoring of phase sequence and phase failure Monitoring of asymmetry selectable Connection of neutral wire optional Detection of loss of neutral wire Supply voltage selectable via power modules |
Original | ||||
| sy10 | G2PM…SY10 Monitoring relays - GAMMA series Voltage monitoring in 3-phase mains Multifunction Monitoring of phase sequence and phase failure Monitoring of asymmetry selectable Connection of neutral wire optional Detection of loss of neutral wire Supply voltage selectable via power modules |
Original | ||||
| E1YF, E1YU Monitoring relays - ENYA series | E1YF, E1YU Monitoring relays - ENYA series Voltage monitoring in 3-phase mains Undervoltage monitoring Supply voltage = measured voltage 1 change over contact Width 17.5 mm Installation design Technical data 1. Functions Undervoltage monitoring in 3-phase mains (each phase against the neutral wire) with fixed or variable threshold voltage US and fixed hysteresis. |
Original | ||||
| phase failure | G2PF…S02 Monitoring relays - GAMMA series Voltage monitoring in 3-phase mains Monitoring of phase sequence and phase failure Detection of reverse voltage Connection of neutral wire optional Supply voltage = measuring voltage 2 change-over contacts Width 22.5mm |
Original | ||||
|
|
||||||
| G2PF…S02 Monitoring relays - GAMMA series Voltage | G2PF…S02 Monitoring relays - GAMMA series Voltage monitoring in 3-phase mains Monitoring of phase sequence and phase failure Detection of reverse voltage Connection of neutral wire optional Supply voltage = measuring voltage 2 change-over contacts Width 22.5mm |
Original | ||||
| Electronic Monitoring Relays Single-phase voltage | Electronic Monitoring Relays Single-phase voltage monitoring ZUZ Technical Details Electrical data Measuring voltage = supply voltage Tolerance Power consumption Switching capability in accordance with EN 60947-4-1, 10/91 The ZUZ electronic DC and AC voltage monitoring relay is designed |
Original | ||||
| sy20 | G2PM..SY20 24-240V Monitoring relays - GAMMA series Voltage monitoring in 3-phase mains Multifunction Monitoring of phase sequence and phase failure Monitoring of asymmetry selectable Connection of neutral wire optional Detection of loss of neutral wire Zoom voltage 24 to 240V AC/DC |
Original | ||||
| E3YF Monitoring relays - ENYA series Voltage | E3YF Monitoring relays - ENYA series Voltage monitoring in 3-phase mains Undervoltage monitoring Supply voltage = measured voltage 2 change over contacts Width 35 mm Installation design Technical data 1. Functions Switching frequency: Undervoltage monitoring in 3-phase mains (each phase against the neutral wire) with fixed adjustable threshold and fixed adjustable hysteresis. |
Original | ||||
| sy20 | G2PM..SY20 24-240V Monitoring relays - GAMMA series Voltage monitoring in 3-phase mains Multifunction Monitoring of phase sequence and phase failure Monitoring of asymmetry selectable Connection of neutral wire optional Detection of loss of neutral wire Zoom voltage 24 to 240V AC/DC |
Original | ||||
| voltage monitoring relay | 3-phase voltage monitoring relay EMR IU11D1, IU21D1 • Voltage monitoring in 3-phase mains • Measuring range 400/230 Vac 3Ph • Monitoring of phase sequence and phase failure • Monitoring of asymmetry • Connection of neutral wire optional • 1 or 2 change-over contacts |
Original | ||||
| e3yu400v02 | E3YU400V02 Monitoring relays - ENYA series Voltage monitoring in 3-phase mains Undervoltage monitoring Supply voltage = meased voltage 2 change over contacts Width 35 mm Installation design Technical data 1. Functions 7. Measuring circuit Undervoltage monitoring in 3-phase mains (each phase against the neutral wire) with adjustable threshold US and fixed adjustable hysteresis. |
Original | ||||
| g2tfkn02 | G2TFKN02 Monitoring relays - GAMMA series Temperature monitoring of the motor winding Short circuit monitoring of thermistor line Zero-voltage latch Supply voltage selectable via power modules 2 change-over contacts External reset key connectable Width 22.5mm |
Original | ||||
| emr su31d | 3-phase voltage monitoring relay EMR SU31D • Voltage monitoring in 3-phase mains • Measuring range 400/230 Vac 3Ph • Monitoring of phase sequence and phase failure • Detection of reverse voltage • Connection of neutral wire optional • 2 changers |
Original | ||||