VDE 0126 Search Results
VDE 0126 Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| 10075025-F01-26ULF | Amphenol Communications Solutions | Minitek®, Wire to Board Connectors, Shrouded Header - Through Mount Pin-in-Paste - Double row - 26 Positions - 2mm (0.079inch) - Vertical | |||
| 66900-126LF | Amphenol Communications Solutions | Quickie Header, Wire to Board Connector, Standard Dual Beam - Double row - 26 Positions - 2.54 mm (0.1 in.) . | |||
| 77313-401-26LF | Amphenol Communications Solutions | BergStik®, Board to Board connector, Unshrouded Header, 2.54 mm Pitch, Vertical, Double Row,Through Hole, 26 Positions | |||
| 77313-101-26LF | Amphenol Communications Solutions | BergStik®, Board to Board connector, Unshrouded Header, 2.54 mm Pitch, Vertical, Double Row,Through Hole, 26 Positions | |||
| 10126113-103HLF | Amphenol Communications Solutions | BergStik®, Board to Board connector, Shrouded vertical header ,Through Hole ,Single row , 3 Positions ,2.54mm (0.100in) Pitch. |
Documents mentioning VDE 0126
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| e3yf400vfal02 | E3YF400VFAL02 Monitoring relays - ENYA series Voltage monitoring in 3-phase mains in accordance with VDE 0126-1-1 Quick net error recognition Supply voltage = measured voltage 2 change over contacts Width 35mm Installation design Technical data 1. Functions |
Original | ||||
| General Purpose Relays Power Relays OEG Power PCB | General Purpose Relays Power Relays OEG Power PCB Relay PCFN Solar n 1 pole 26A, 1 form A (NO) contact gap >1.5mm n 200mW hold power n Ambient temperature up to 75°C, 85°C at 22A n The appliance is able to meet VDE V 0126-1-1 n Contact Typical applications |
Original | ||||
| General Purpose Relays Power Relays Potter & | General Purpose Relays Power Relays Potter & Brumfield Power PCB Relay T9S Solar n 1 pole 35A, 1 form A (NO) contact gap >1.5mm n 350mW hold power n Ambient temperature up to 85°C at 35A n The appliance is able to meet VDE V 0126-1-1 n Product in accordance to IEC 60335-1 |
Original | ||||
| Relay Coupler 58 Relay Coupler Contact material | Relay Coupler 58 Relay Coupler Contact material Properties Application Fine silver AG 99 % - inexpensive - average tendency to weld and average resistance to burn-off - subject to corrosion in sulphurous atmosphere - high mechanical stability - low tendency to weld |
Original | ||||
| Table of Contents Measuring Instruments GMC-I | Table of Contents Measuring Instruments GMC-I Messtechnik GmbH GMC-Instruments Nederland B.V. Daggeldersweg 18 NL-3449 JD Woerden Phone: +31 348 42 11 55 Fax: +31 348 42 25 28 E-mail: info@gmc-instruments.nl www.gmc-instruments.nl GMC-Instruments Austria GmbH |
Original | ||||
| 600233 | n ^ ri = j I z i~ ~ * — C Box for PV M odule t S/n-nm 2» Junction Box For Silicon W afer PV Module Certificate Zertifikat TÜVRheinland Zertifikat Nr. Certificate No. Blatt Page R 600233B8 0001 Ihr Zeichen Client Reference Unser Zeichen Our Reference Ausstellungsdatum |
OCR Scan | ||||
| SolarMax C-Series single-phase inverters Caring | SolarMax C-Series single-phase inverters Caring for the environment – as well as for your pocket. Your interest in renewable energy is a clear indication that you are one of those who are aware of the signs of the times. For people like you who are concerned about environmental protection, and who understand that living |
Original | ||||
| pv Standard type PV Connector "YSOL-3 «« A | pv Standard type PV Connector "YSOL-3 «« A Certificate Zertifikat TUVRheinland Zertifikat Nr. Certificate \o . Blatt Page R 60023264 0001 Unser Zeichen Our Reference Ihr Zeichcn Client Reference 00 01 - - 21134597 001 1 9 . 0 1 .2 0 0 9 Date o f Issue (day/mo/yr) |
OCR Scan | ||||
| Produktübersicht Relaiskoppler / Relaissockel | Produktübersicht Relaiskoppler / Relaissockel Relaiskoppler mit 1 Schließer oder 1 Öffner Relaiskoppler mit 2,8 mm Flachsteckanschluß Seite 6-5/4 Relaiskoppler 1 Öffner / 1 Schließer Seite 6-5/5 Relaiskoppler mit 2 x 1 Wechsler oder 3 x 1 Schließer |
Original | ||||
| Three-phase monitoring relay for grid feeding | Three-phase monitoring relay for grid feeding CM-UFS.1 2CDC 251 014 F0t09 NEW Data sheet Features � CM-UFS.1 R/T: yellow LED relay status, timing F1: red LED fault message F2: red LED fault message Adjustment of the threshold |
Original | ||||
| The Power in Electrical Safety Main Catalogue | The Power in Electrical Safety Main Catalogue Edition 1/2014 BENDER Group Main Catalogue Edition 1/2014 Subject to change! – © Bender GmbH & Co. KG, Germany The catalogue and the articles and illustrations which it contains are protected by copyright. Distribution, translation, microfilming and storing in electronic systems, particularly for commercial purposes, are not permitted without prior permission from the author. We accept no liability |
Original | ||||
| System pro M compact ȭ Technical data System | System pro M compact ȭ Technical data System Navigate pro MDocument compact ® Miniature circuit-breakers S 200/S 200 M Residual-current-operated circuit-breakers F 200 Cross wiring/accessories 1 System pro M compact ® Miniature circuit-breaker S 201 Standard Terms for Delivery and Sale |
Original | ||||
| CM-UFS.1 CM-UFS.2 Betriebs- und Montageanleitung | CM-UFS.1 CM-UFS.2 Betriebs- und Montageanleitung Dreiphasenüberwachungsrelais für Netzeinspeisungen, CM Reihe (E) Nota: Estas instrucciones no contienen todas las informaciones detalladas relativas a todos los tipos del producto ni pueden considerar todos los casos de operación. |
Original | ||||
| Measuring and monitoring relays CM and C5xx | Measuring and monitoring relays CM and C5xx range 2 Content Benefits and advantages… 2/ 2 Monitoring features and application ranges… 2/ 4 |
Original | ||||
|
|
||||||
| Produktübersicht Bausteine Schalter-und | Produktübersicht Bausteine Schalter-und Tasterbausteine Anzeigenbausteine Sicherungsbausteine Gleichrichterbausteine Schnittstellenbausteine für Näherungsschalter Melde- und Befehlsbausteine Seite 6-2/4 Gleichrichterbausteine Seite 6-2/5 Diodengatter Seite 6-2/6 |
Original | ||||