Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    USING HOTLINK Search Results

    USING HOTLINK Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    10160298-1111102LF
    Amphenol Communications Solutions BergStak® Secure Connector, Right Angle Header, 3x37positions, One-time use, Right Guide PDF
    10160298-1111100LF
    Amphenol Communications Solutions BergStak® Secure Connector, Right Angle Header, 3x37positions, One-time use PDF
    10160298-1111002LF
    Amphenol Communications Solutions BergStak® Secure Connector, Right Angle Header, 3x37positions, Multi-times use, Right Guide PDF
    10160298-1111011LF
    Amphenol Communications Solutions BergStak® Secure Connector, Right Angle Header, 3x37positions, Multi-times use, Left Screw hole, Left Guide PDF
    10160298-1111000LF
    Amphenol Communications Solutions BergStak® Secure Connector, Right Angle Header, 3x37positions, Multi-times use PDF

    USING HOTLINK Datasheets (1)

    Cypress Semiconductor
    Part ECAD Model Manufacturer Description Datasheet Type PDF PDF Size Page count
    Using HOTLink
    Cypress Semiconductor Using HOTLink with Long Copper Cables Original PDF 744.88KB 12

    Documents mentioning USING HOTLINK

    Document Partial File Text Tags Type PDF
    an4059
    AN4059 Associated Project: No Associated Part Family: CYV15G0401DXB Software Version: NA Associated Application Notes: None Clocking Options When Using HOTLink IITM Devices in HD-SDI Video Applications Abstract AN4059 discusses the various clocking options that can be used in these applications when using the HOTLink II
    Original PDF
    using decoupling capacitors
    Using Decoupling Capacitors Introduction Bypassing: The practice of adding a lowĆimpedance path to shunt This application note describes some revised recomĆ mendations regarding the use of decoupling capaciĆ tors. The conventional" recommendation of using
    Original PDF
    Using Decoupling Capacitors Introduction This
    Using Decoupling Capacitors Introduction This application note describes a number of revised recommendations regarding the use of decoupling capacitors. Network analysis is used to prove that the “conventional” recommendation of using widely spaced values can, in many
    Original PDF
    Using Decoupling Capacitors Introduction This
    Using Decoupling Capacitors Introduction This application note describes a number of revised recommendations regarding the use of decoupling capacitors. Network analysis is used to prove that the “conventional” recommendation of using widely spaced values can, in many
    Original PDF
    Using Decoupling Capacitors Introduction This
    Using Decoupling Capacitors Introduction This application note describes a number of revised recommendations regarding the use of decoupling capacitors. Network analysis is used to prove that the “conventional” recommendation of using widely spaced values can, in many
    Original PDF
    fax id: 4504 Using Decoupling Capacitors
    fax id: 4504 Using Decoupling Capacitors Introduction This application note describes some revised recommendations regarding the use of decoupling capacitors. The “conventional” recommendation of using two different values and two different types can, in many circumstances, cause less
    Original PDF
    cys25g0101dx
    High-speed Board Design Guidelines (using CYS25G0101DX as an example) Introduction This application note describes high-speed board design guidelines using the CYS25G0101DX as an example. The CYS25G0101DX is a SONET OC-48 Transceiver that provides complete parallel-to-serial and serial-to-parallel conversions, clock and data recovery, and clock synthesis functions
    Original PDF
    Frequently Asked Questions about HOTLinkt
    Frequently Asked Questions about HOTLinkt Evaluation Boards The following questions are frequently asked by customers who are using HOTLinkt Evaluation Boards. These cursory answers will serve as an introduction for each topic. Separate application notes cover these
    Original PDF
    cyclic redundancy check
    fax id: 5111 Parallel Cyclic Redundancy Check (CRC) for HOTLink™ Introduction leaves us with predominantly double-bit errors with which to deal. This note discusses using CRC codes to insure data integrity over high-speed serial links, such as Fibre Channel,
    Original PDF
    HOTLink™-Based Data-Mover Introduction This
    HOTLink™-Based Data-Mover Introduction This application note details the design and implementation of a generic data-mover based on the Cypress HOTLink™ high-speed serial interface transmitter/receiver ICs. The design is implemented using clocked FIFOs for data storage, a
    Original PDF
    hotlink
    Implementing Automatic Rate Detection Function for the SMPTE Rates of 270, 1483.5, and 1485 Mb/s using the HOTLinkII SERDES AN5007 1.0 Introduction rate detection circuit that detects the most common SDI rates: 270, 1483.5 and 1485 Mb/s. Figure 1 displays the
    Original PDF
    an5008
    Implementing Automatic Rate Detection for SMPTE Rates of 270, 360, 540, 1483.5, and 1485 Mb/s using the HOTLink II(TM) SERDES AN5008 Introduction Automatic rate detection is a solution to detect the multipleformats as specified by The Society of Motion Picture and
    Original PDF
    an1077
    AN1077 Replacing Wire with Inexpensive Plastic Fiber Solutions Associated Project: No ® Associated Part Family: HOTLink Software Version: N/A Associated Application Notes: AN1130, AN1032 Abstract AN1077 explains the advantages of low cost fiber-optic solution and ways to implement it using Cypress
    Original PDF
    an1089
    AN1089 Associated Project: No Associated Part Family: CY7B923/CY7B933 Software Version: NA Associated Application Notes: AN1274 Parallel Cyclic Redundancy Check (CRC) for HOTLink® Abstract AN1089 discusses using CRC codes to insure data integrity over high-speed serial links, such as Fibre Channel,
    Original PDF
    Frequently Asked Questions about HOTLink™
    Frequently Asked Questions about HOTLink™ Evaluation Boards The following questions are frequently asked by customers who are using HOTLink™ Evaluation Boards. These cursory answers will serve as an introduction for each topic. Separate application notes cover these topics in more complete detail.
    Original PDF
    an1161
    HOTLink Jitter Characteristics AN1161 Application Note Abstract This application note describes the basics of jitter in transmission systems and, using HOTLink™ as the example, shows how it can be analyzed and measured. Specific characterization data is presented to allow system integrators to understand the
    Original PDF
    t HOTLink Jitter Characteristics Abstract This
    t HOTLink Jitter Characteristics Abstract This application note describes the basics of jitter in transmission systems and, using HOTLink as the example, shows how it can be analyzed and meaĆ sured. Specific characterization data is presented that will allow system integrators to understand the
    Original PDF
    fax id: 5109 HOTLink™ Jitter Characteristics
    fax id: 5109 HOTLink™ Jitter Characteristics Abstract This application note describes the basics of jitter in transmission systems and, using HOTLink™ as the example, shows how it can be analyzed and measured. Specific characterization data is presented that will allow system integrators to
    Original PDF
    Using HOTLinkt with Long Copper Cables Overview
    Using HOTLinkt with Long Copper Cables Overview The use of HOTLinkt data communications proĆ ducts to drive copper media is documented in a Cypress application note titled Driving Copper Cables with HOTLink." Long transmission lines (those that cannot be treated as lossless) present
    Original PDF
    Using HOTLink® with Long Copper Cables Overview
    Using HOTLink® with Long Copper Cables Overview Skin Effect HOTLink® The use of data communications products to drive copper media is documented in a Cypress application note titled “Driving Copper Cables with HOTLink.” Long transmission lines (those that cannot be treated as lossless) present
    Original PDF
    cy7c924adx
    CY7C924ADX 200 MBaud HOTLink® Transceiver Features • Second generation HOTLink® technology • Fibre Channel and ESCON® compliant 8B/10B encoder/decoder • 10 or 12 bit preencoded data path (raw mode) • 8 or 10 bit encoded data transport (using 8B/10B coding)
    Original PDF
    asi
    Implementing DVB-ASI Serial Interfaces Using HOTLink® Introduction DVB-ASI Protocol Description Digital Video Broadcast - Asynchronous Serial Interface (DVB-ASI) has been widely adopted as one of the standard interfaces for transporting one or more MPEG-2 (Motion Picture Experts Group) transport streams between professional
    Original PDF
    cy7c924adx
    CY7C924ADX 200 MBaud HOTLink® Transceiver Features • Second generation HOTLink® technology • Fibre Channel and ESCON® compliant 8B/10B encoder/decoder • 10 or 12 bit preencoded data path (raw mode) • 8 or 10 bit encoded data transport (using 8B/10B coding)
    Original PDF
    Using HOTLink™ with Long Copper Cables Overview
    Using HOTLink™ with Long Copper Cables Overview Skin Effect The use of HOTLink™ data communications products to drive copper media is documented in a Cypress application note titled “Driving Copper Cables with HOTLink.” Long transmission lines (those that cannot be treated as lossless) present
    Original PDF
    fax id: 5103 Frequently Asked Questions about
    fax id: 5103 Frequently Asked Questions about HOTLink™ Evaluation Boards The following questions are frequently asked by customers who are using HOTLink™ Evaluation Boards. These cursory answers will serve as an introduction for each topic. Separate application notes cover these topics in more complete detail.
    Original PDF