Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    UNBALANCE LOAD, POWER LOSS Search Results

    UNBALANCE LOAD, POWER LOSS Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    MGN1D120603MC-R7
    Murata Manufacturing Co Ltd DC-DC 1W SM 12-6/-3V GAN PDF
    MGN1D050603MC-R7
    Murata Manufacturing Co Ltd DC-DC 1W SM 5-6/-3V GAN PDF
    MGN1S0512MC-R7
    Murata Manufacturing Co Ltd DC-DC 1W SM 5-12V GAN PDF
    MGN1S1212MC-R7
    Murata Manufacturing Co Ltd DC-DC 1W SM 12-12V GAN PDF
    MGN1S1208MC-R7
    Murata Manufacturing Co Ltd DC-DC 1W SM 12-8V GAN PDF

    UNBALANCE LOAD, POWER LOSS Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    Contextual Info: Mini-Circuits - Specification for Power Splitter - PSC-4-1 Power Splitter Notes: • Internal load dissipation: 0.25 Watt. • Matched power rating: 1 Watt. • For Insertion Loss Max. L and Amplitude Unbalance Max. (L): Adjacent Ports, 25°C. • General Quality Control Procedures and Environmental Specifications are given in Mini-Circuits Guarantees Quality.


    Original
    PDF

    mfr 34078

    Abstract: E5400
    Contextual Info: NOTES: 1.0 ELECTRICAL SPECIFICATIONS: 1.1 FREQUENCY RANGE: 0 .5 to 2 .0 GHz 1.2 INSERTION LOSS: 1.0dB MAX. 1.3 ISOLATION: 15dB MIN. 1.4 VSWR: 1.5:1 MAX 1.5 OUTPUT UNBALANCE: AMPLITUDE: 0 .5 d B MAX. PHASE: 5° MAX. 1.6 MAX. INPUT POWER: 5 WATTS WITH OUTPUT LOAD VSWR


    OCR Scan
    PWD-5520-03-SMA-79 mfr 34078 E5400 PDF

    Contextual Info: NOTES: 1.0 ELECTRICAL SPECIFICATIONS: 1.1 FREQUENCY RANGE: 46 0 to 2 2 0 0 MHz 1.2 INSERTION LOSS: 0.5dB MAX. 1.3 ISOLATION: 20dB MIN. 1.4 VSWR MAX : 1.25:1 1.5 OUTPUT UNBALANCE: 1.5.1 AMPLITUDE: 0.2dB MAX. 1.5.2 PHASE: 4.0* MAX. 1.6 MAX. INPUT POWER: 3 WATTS WITH OUTPUT LOAD VSWR < 2.0:1


    OCR Scan
    D-5520-02-SM PDF

    Contextual Info: REV. Sta tu s REVISION 06/01/01 YS SURFAC E MOUNT HYBRID TRANSFORMER % A. Electrical specifications @ 25'C 1. Pri source im pedance; 6000 2. Sec load im pedance; 6000 3. MAX output power; —4 5 ~ + 7 d Bm 4. Frequency response; ±0.5, 300Hz to 3.5KHz 5. DC unbalance; 0mA


    OCR Scan
    300Hz 200Hz 1500Vrms 500Vrms PDF

    HYBRID TRANSFORMER

    Abstract: CSA-C22 TS1104 950-M89
    Contextual Info: REV. Sta tu s REVISION 06/01/01 YS SURFAC E MOUNT HYBRID TRANSFORMER % A. Electrical specifications @ 25'C 1. Pri source im pedance; 6000 2. Sec load im pedance; 6000 3. MAX output power; —4 5 ~ + 7 d Bm 4. Frequency response; ±0.5, 300Hz to 3.5KHz 5. DC unbalance; 0mA


    OCR Scan
    300Hz 200Hz 1500Vrms 500Vrms 300Hz, TS1104, origi271 TS1104 HYBRID TRANSFORMER CSA-C22 950-M89 PDF

    Contextual Info: REV. S ta tu s REVISION 0 6 / 1 8 / 9 6 TS A. Electrical specifications @ 25 ° C 1. Pri Source Impedance; 600 0 ±10% 2. Sec Load Impedance; 5 20 0 3. MAX Output Power; 3 dBm (2 mW) 4. Frequency Response; ± 0 .5 dB 3 00 Hz to 3.5 KHz 5. DC Unbalance; 0 mA


    OCR Scan
    PDF

    Contextual Info: REV. S ta tu s REVISION 0 6 /1 8 /9 6 TS A. Electrical specifications 25 ° C 1. Pri Source Impedance; 600 0 ± 1 0 % 2. Sec Load Impedance; 520 0 3. MAX Output Power; 3 dBm (2 mW) 4. Frequency Response; ± 0 .5 dB 300 Hz to 3.5 KHz 5. DC Unbalance; 0 mA


    OCR Scan
    PDF

    monitoring relay cm-pas

    Abstract: 3 phase monitor Federal Isolating Switch F0512A F018 LED monitor circuit diagram DC-12 DC-13 F0004 R0100
    Contextual Info: Measuring and monitoring relay CM-PAS Three-phase monitor for phase unbalance Data sheet 2CDC 251 050 F0004 Features ᕄ ᕅ ᕃ ᕆ ᕇ ½ ½ ½ ½ ½ ½ ½ Three-phase monitoring of phase sequence, phase loss and phase unbalance Adjustable unbalance threshold


    Original
    F0004 F0188 F0003 F0182 F0179 F0181 D0201 monitoring relay cm-pas 3 phase monitor Federal Isolating Switch F0512A F018 LED monitor circuit diagram DC-12 DC-13 F0004 R0100 PDF

    IRF9460

    Abstract: irfp460 ir2110 mosfet IRF450 IR2110 dc motor ir2110 class d amp ir2110 with calculations for 3 phase inverter ir2110 with calculations for inverter irfp460 inverter IR2110 buck Class d IR2110
    Contextual Info: Index INT990 Application Characterization of IGBTs HEXFRED is a trademark of International Rectifier Topics Covered: Gate drive for IGBTs Safe Operating Area Conduction losses Statistical models Switching losses Device selection and optimization Spreadsheets to calculate power losses and junction temperature


    Original
    INT990 INT-983, IRF9460 irfp460 ir2110 mosfet IRF450 IR2110 dc motor ir2110 class d amp ir2110 with calculations for 3 phase inverter ir2110 with calculations for inverter irfp460 inverter IR2110 buck Class d IR2110 PDF

    MOSFET 4407

    Abstract: IRF9460 ir2110 class d amp irfp460 ir2110 AN-941 IRFP450 inverter irfp450 mosfet full bridge ir2110 with calculations for inverter full bridge ir2110 4407 mosfet
    Contextual Info: INT990 Application Characterization of IGBTs HEXFRED is a trademark of International Rectifier Topics Covered: Gate drive for IGBTs Safe Operating Area Conduction losses Statistical models Switching losses Device selection and optimization Spreadsheets to calculate power losses and junction temperature


    Original
    INT990 INT-983, MOSFET 4407 IRF9460 ir2110 class d amp irfp460 ir2110 AN-941 IRFP450 inverter irfp450 mosfet full bridge ir2110 with calculations for inverter full bridge ir2110 4407 mosfet PDF

    IRF9460

    Abstract: ir2110 spice IR2110 IGBT DRIVER irfp460 ir2110 INT-983 IRGP50S ir2110 with calculations for 3 phase inverter IR2121 irfp450 mosfet IRCPC50F
    Contextual Info: Application Note AN-990 Application Characterization of IGBTs Table of Contents Page I. Gate Drive Requirements . 1 I. A Impact of the impedance of the gate drive circuit on switching losses. 1


    Original
    AN-990 IRF9460 ir2110 spice IR2110 IGBT DRIVER irfp460 ir2110 INT-983 IRGP50S ir2110 with calculations for 3 phase inverter IR2121 irfp450 mosfet IRCPC50F PDF

    loss of neutral monitor

    Abstract: F0003 CM-MPS LED monitor circuit diagram R0100 R1300 3 phase monitoring relays 60947-5-1 abb heidelberg circuit R3300
    Contextual Info: Measuring and monitoring relays CM-MPS Multifunctional three-phase monitor Data sheet 2CDC 251 005 F0003 Features ᕆ ᕄ ᕅ ᕃ ᕇ ᕉ ᕈ ½ ½ ½ ½ ½ ½ ½ ½ ½ Three-phase monitoring of phase sequence, phase loss, over- and undervoltage and phase unbalance


    Original
    F0003 voltag185 F0189 F0188 F0182 F0179 D0201 F0181 loss of neutral monitor F0003 CM-MPS LED monitor circuit diagram R0100 R1300 3 phase monitoring relays 60947-5-1 abb heidelberg circuit R3300 PDF

    Contextual Info: The PMP Series Phase Monitor Relays utilize a microprocessor-based design to provide protection against phase loss, phase reversal, phase unbalance, undervoltage and overvoltage. The PMPU is a universal voltage product that works on any three-phase system voltage from 208-480V a separate 120V


    Original
    08-480V 08480V 08-480V 100ms E109466 EN60947-1, EN60947-5-1 PDF

    APMR0096

    Abstract: 480 v reverse phasing wire diagram E137808 Schaffner catalog 28B2029-0A0 LFIL0000 ZCAT3035-1330A wye delta start wiring diagram single phase reverse motor wye to delta wiring diagram AC motor
    Contextual Info: Bulletin No. APMR-E Drawing No. LP0376 Released 2/07 Tel +1 717 767-6511 Fax +1 (717) 764-0839 www.redlion.net MODEL APMR - 3 PHASE FAULT DETECTION DIN RAIL MODULE z PROTECTS AGAINST PHASE LOSS, UNBALANCE, UNDER VOLTAGE, AND PHASE REVERSAL z AVAILABLE IN 230, 380, OR 480 VAC


    Original
    LP0376 E137808 APMR0096 480 v reverse phasing wire diagram E137808 Schaffner catalog 28B2029-0A0 LFIL0000 ZCAT3035-1330A wye delta start wiring diagram single phase reverse motor wye to delta wiring diagram AC motor PDF

    208-480V

    Abstract: phase sequence indicator EN60947-1 EN60947-5-1 70169-D 120v relay 11 pin diagram three phase sequence 600V-rated unbalance load, power loss
    Contextual Info: PHASE MONITOR RELAYS Phase Loss, Phase Reversal, Phase Unbalance, and Under/Over Voltage PMP Series Plug-in u Universal voltage range of 208-480V on PMPU provides the flexibility to cover a variety of applications with one unit u Protects against phase loss,


    Original
    08-480V 100ms EN60947-1, EN60947-5-1 E109466 70169-D 208-480V phase sequence indicator EN60947-1 EN60947-5-1 120v relay 11 pin diagram three phase sequence 600V-rated unbalance load, power loss PDF

    EN60947-1

    Abstract: EN60947-5-1 three phase sequence 208-480V phase sequence protection PMD120
    Contextual Info: PHASE MONITOR RELAYS Phase Loss, Phase Reversal, Phase Unbalance, and Under/Over Voltage PMD Series Surface-Mount u Universal voltage range of 208-480V on PMDU provides the flexibility to cover a variety of applications with one unit u Protects against phase loss,


    Original
    08-480V 150oF) 100ms EN60947-1, EN60947-5-1 E109466 EN60947-1 EN60947-5-1 three phase sequence 208-480V phase sequence protection PMD120 PDF

    MOSFET 4407

    Abstract: ir2110 class d amp IRFP450 inverter irfp460 ir2110 Class d IR2110 inverter ic 3524 application ir2110 with calculations for inverter BJT with V-I characteristics INT-983 Inverter IR2110
    Contextual Info: Application Note AN-990 Application Characterization of IGBTs Table of Contents Page I. Gate Drive Requirements . 1 I. A Impact of the impedance of the gate drive circuit on switching losses. 1


    Original
    AN-990 MOSFET 4407 ir2110 class d amp IRFP450 inverter irfp460 ir2110 Class d IR2110 inverter ic 3524 application ir2110 with calculations for inverter BJT with V-I characteristics INT-983 Inverter IR2110 PDF

    PLMU-11

    Contextual Info: Voltage Monitors PLMU Series The PLMU Series continuously measures the voltage of each of the three phases to provide protection for 3-phase motors and sensitive loads. Its microcontroller senses under and overvoltage, voltage unbalance, phase loss, and phase reversal.


    Original
    PDF

    Contextual Info: Voltage Monitors PLM Series The PLM Series continuously measures the voltage of each of the three phases. The PLM Series uses a microcontroller circuit design that senses undervoltage, voltage unbalance, phase loss, and phase reversal. Protection is assured when


    Original
    PDF

    208-480V

    Abstract: EN60947-1 EN60947-5-1 PMD600
    Contextual Info: PHASE MONITOR RELAYS Phase Loss, Phase Reversal, Phase Unbalance, and Under/Over Voltage PMD Series Surface-Mount u Universal voltage range of 208-480V on PMDU provides the flexibility to cover a variety of applications with one unit u Protects against phase loss,


    Original
    08-480V 150oF) 100ms EN60947-1, EN60947-5-1 E109466 208-480V EN60947-1 EN60947-5-1 PMD600 PDF

    Contextual Info: The PMD Series Phase Monitor Relays utilize a microprocessor-based design to provide protection against phase loss, phase reversal, phase unbalance, undervoltage and overvoltage. The PMDU is a universal voltage product that works on any three-phase system voltage from 208-480V separate 120V & 575V


    Original
    08-480V 08480V 08-480V EN60947-1, EN60947-5-1 E109466 PDF

    Contextual Info: Voltage Monitors TVW Series Provides protection for motors and other sensitive loads. Continuously measures the voltage of each of the three phases using a microcontroller circuit design that senses under and overvoltage, voltage unbalance, phase loss, and phase reversal.


    Original
    PDF

    Contextual Info: Voltage Monitors TVM Series Provides protection for motors and other sensitive loads. Continuously measures the voltage of each of the three phases using a microcomputer circuit design that senses under and overvoltage, voltage unbalance, phase loss, and phase reversal.


    Original
    PDF

    Contextual Info: The PMP-FA Series Phase Monitor Relays utilize a microprocessor-based design to provide protection against phase loss, phase reversal, phase unbalance, undervoltage and overvoltage, and are compatible with most Wye or Delta systems with no connection to Neutral required. They protect against unbalanced


    Original
    08-480V E109466 00V-rated 149oF) PDF