Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    UL 1059 TORQUE Search Results

    UL 1059 TORQUE Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    DRV8452DDWR
    Texas Instruments 50-V, 5-A, dual H-bridge stepper motor driver with smart tune, stall detect and auto-torque 44-HTSSOP -40 to 125 Visit Texas Instruments
    DRV8461PWPR
    Texas Instruments 65-V, 3-A dual H-bridge stepper motor driver with smart tune, stall detect and auto-torque 28-HTSSOP -40 to 125 Visit Texas Instruments
    DRV8461DDWR
    Texas Instruments 65-V, 3-A dual H-bridge stepper motor driver with smart tune, stall detect and auto-torque 44-HTSSOP -40 to 125 Visit Texas Instruments
    DRV8461SPWPR
    Texas Instruments 65-V, 3-A dual H-bridge stepper motor driver with smart tune, stall detect and auto-torque 28-HTSSOP -40 to 125 Visit Texas Instruments
    DRV8452SPWPR
    Texas Instruments 50-V, 5-A, dual H-bridge stepper motor driver with smart tune, stall detect and auto-torque 28-HTSSOP -40 to 125 Visit Texas Instruments

    Documents mentioning UL 1059 TORQUE

    Document Partial File Text Tags Type PDF
    FILTERED TERMINAL BLOCKS Eliminate
    FILTERED TERMINAL BLOCKS Eliminate Electromagnetic Interference (EMI) UL Standard 1059 Compliant Te rminal Blo c k s CTS UL-recognized filtered terminal blocks are specifically designed to save time and money for EMI filtering applications. By combining a filtering component with an industry standard terminal block, CTS
    Original PDF
    AK 100 VERTICAL AK 100 HORIZONTAL AK 100/.. - 5,0
    AK 100 VERTICAL AK 100 HORIZONTAL AK 100/.. - 5,0 - V - grey AK 100/.. - 5,0 - H - grey 2-12 poles, Spacing 5,0 mm insert required no. of poles .. 2-12 poles, Spacing 5,0 mm insert required no. of poles .. Ratings: Ratings: UL 1059 Rated Voltage Rated Current
    Original PDF
    AK 2200 VERTICAL AK 2200 HORIZONTAL AK 2200/.. -
    AK 2200 VERTICAL AK 2200 HORIZONTAL AK 2200/.. - 5,0 - V - green AK 2200/.. - 5,0 - H - green 1-n poles, Spacing 5,0 mm insert required no. of poles .. 1-n poles, Spacing 5,0 mm insert required no. of poles .. Ratings: Ratings: UL 1059 Rated Voltage Rated Current
    Original PDF
    AK 550 VERTICAL AK 550 HORIZONTAL AK 550/.. - 3,5
    AK 550 VERTICAL AK 550 HORIZONTAL AK 550/.. - 3,5 - V - grey AK 550/.. - 3,5 - H - grey 2-16 poles, Spacing 3,5 mm insert required no. of poles .. 2-16 poles, Spacing 3,5 mm insert required no. of poles .. Ratings: Ratings: UL 1059 Rated Voltage Rated Current
    Original PDF
    st723b38
    Studded Power Feed Thru Terminal Blocks ST723B38 Series (back mount) Specifications: • 600 Volts AC/DC (UL 1059 Class B and C) 380 Amps Wire Range 500 kcmil - 2/0 AWG Accommodates Two Hole Compression Lugs on 1” Centers - wires larger than 250 kcmil require
    Original PDF
    AKZ 120 VERTICAL AKZ 120 HORIZONTAL AKZ 120/.. -
    AKZ 120 VERTICAL AKZ 120 HORIZONTAL AKZ 120/.. - 5,08 - V - grey AKZ 120/.. - 5,08 - H - grey 2-12 poles, Spacing 5,08 mm insert required no. of poles .. 2-12 poles, Spacing 5,08 mm insert required no. of poles .. Ratings: Ratings: UL 1059 Rated Voltage Rated Current
    Original PDF
    st715s1902
    Studded Power Feed Thru Terminal Blocks ST715S1902 Electrical: • 300 Volts AC/DC (UL 1059 Class B and C) 80 Amps Wire Range #6 - #14 Accommodates Two Hole Compression Lugs on .625” Centers General/Mechanical: •
    Original PDF
    st722b
    Studded Power Feed Thru Terminal Blocks ST722B Series (back mount) Studded Power Feed Thru Terminal Blocks Specifications: Electrical: • 300 Volts AC/DC (UL 1059 Class B and C) 175 Amps Wire Range 2/0 - #8 Accommodates Two Hole Compression Lugs on .625”
    Original PDF
    st722e
    Studded Power Feed Thru Terminal Blocks ST722E Series (end mount) Specifications: Studded Power Feed Thru Terminal Blocks Electrical: • 300 Volts AC/DC (UL 1059 Class B and C) 175 Amps Wire Range 2/0 - #8 Accommodates Two Hole Compression Lugs on .625”
    Original PDF
    st722
    Studded Power Feed Thru Terminal Blocks ST722S Series (slide-in mount) Studded Power Feed Thru Terminal Blocks Specifications: Electrical: • 300 Volts AC/DC (UL 1059 Class B and C) 175 Amps Wire Range 2/0 - #8 Accommodates Two Hole Compression Lugs on .625”
    Original PDF
    1059
    AK(Z) 950 AKZ 960 AK(Z) 950/.. - 5,0 (5,08) - green AKZ 960/.. - 7,62 - green 2-24 poles, Spacing 5,0 mm or 5,08 mm insert required no. of poles .. 2-16 poles, Spacing 7,62 mm insert required no. of poles .. Ratings: Ratings: UL 1059 Rated Voltage Rated Current
    Original PDF
    Product Data Sheet 144X122 Replace “X” with 1, 2
    Product Data Sheet 144X122 Replace “X” with 1, 2 or 3 for number of poles Power Stud Block 260 Amps, 600 Volts (AC/DC) Wire Range: Line side: Listed ring lugs or bus bars Load Side: Listed ring lug or bus bars Electrical Ratings: • 260A • 600 Volts AC/DC (UL 1059 Class C, User Group - General Industrial)
    Original PDF
    Product Data Sheet 144X614 Replace “X” with 1, 2
    Product Data Sheet 144X614 Replace “X” with 1, 2 or 3 for number of poles Power Stud Block 840 Amps, 600 Volts (AC/DC) Wire Range: Line side: Listed ring lugs or bus bars Load Side: Listed ring lug or bus bars Electrical Ratings: • 840A • 600 Volts AC/DC (UL 1059 Class C, User Group - General Industrial)
    Original PDF
    144x553
    Product Data Sheet 144X553 Replace “X” with 1, 2 or 3 for number of poles Power Stud Block 230 Amps, 600 Volts (AC/DC) Wire Range: Line side: Listed ring lugs or bus bars Load Side: Listed ring lug or bus bars Electrical Ratings: • 230A • 600 Volts AC/DC (UL 1059 Class C, User Group - General Industrial)
    Original PDF
    142x122
    Product Data Sheet 142X122 Replace “X” with 1, 2 or 3 for number of poles Power Stud Block 200 Amps, 600 Volts (AC/DC) Wire Range: Line side: Listed ring lugs or bus bars Load Side: Listed ring lug or bus bars Electrical Ratings: • 200A • 600 Volts AC/DC (UL 1059 Class C, User Group - General Industrial)
    Original PDF
    143x563
    Product Data Sheet 143X563 Replace “X” with 1, 2 or 3 for number of poles Power Stud Block 230 Amps, 600 Volts (AC/DC) Wire Range: Line side: Listed ring lugs or bus bars Load Side: Listed ring lug or bus bars Electrical Ratings: • 230A • 600 Volts AC/DC (UL 1059 Class C, User Group - General Industrial)
    Original PDF
    Product Data Sheet 145X606 Replace “X” with 1, 2
    Product Data Sheet 145X606 Replace “X” with 1, 2 or 3 for number of poles Power Stud Block 410 Amps, 600 Volts (AC/DC) Wire Range: Line side: 1/2 - 13 X 1 5/16 stud Load Side: 1/2 - 13 X 1 5/16 stud Electrical Ratings: • 410A copper wire • 600 Volts AC/DC (UL 1059 Class C, User Group - General Industrial)
    Original PDF
    Product Data Sheet 145X583 Replace “X” with 1, 2
    Product Data Sheet 145X583 Replace “X” with 1, 2 or 3 for number of poles Power Stud Block 360 Amps, 600 Volts (AC/DC) Wire Range: Line side: (1) 3/8 - 16 X 1 7/16 stud Load Side: (2) 1/4 - 20 X 1 7/16 stud Electrical Ratings: • 360A copper wire • 600 Volts AC/DC (UL 1059 Class C, User Group - General Industrial)
    Original PDF
    Product Data Sheet 145X573 Replace “X” with 1, 2
    Product Data Sheet 145X573 Replace “X” with 1, 2 or 3 for number of poles Power Stud Block 360 Amps, 600 Volts (AC/DC) Wire Range: Line side: (1) 3/8 - 16 X 1 7/16 stud Load Side: (2) 3/8 - 16 X 1 7/16 stud Electrical Ratings: • 360A copper wire • 600 Volts AC/DC (UL 1059 Class C, User Group - General Industrial)
    Original PDF
    Product Data Sheet 1XX Series Std Replace “XX”
    Product Data Sheet 1XX Series Std Replace “XX” with 01 through 36 for number of poles Terminal Block– Closed Back 20 Amps, 250 Volts (AC/DC) (6 Pole shown) Copper Wire Only Wire Range with Wire Binding Screw: #12 - #22 AWG 3/8” Centers See table below for Wire Classes and torque
    Original PDF
    6g38 tskk f
    Product Data Sheet 6G38 TSKK F 3/8” Sectional Terminal Block Flat Mount 40 Amps, 600 Volts (AC/DC) 32 Circuits Per Foot Copper Wire Only Wire Range with Wire Binding Screw: #10 - #22 AWG TSKK: Tubular Connector with Wire Protector Wire Termination Torque: 16 in. lbs
    Original PDF
    Product Data Sheet 6H12-TSCU-F 1/2” Sectional
    Product Data Sheet 6H12-TSCU-F 1/2” Sectional Terminal Block Flat Mount 70 Amps, 600 Volts (AC/DC) 24 Circuits Per Foot Copper Wire Only Wire Range with Wire Binding Screw: #4 - #16 AWG TS: Tubular Screw Wire Termination Torque: 20 in. lbs See table below for Wire Classes and torque
    Original PDF
    Product Data Sheet 6G38 TSKK F 3/8” Sectional
    Product Data Sheet 6G38 TSKK F 3/8” Sectional Terminal Block Flat Mount 40 Amps, 600 Volts (AC/DC) 32 Circuits Per Foot Copper Wire Only Wire Range with Wire Binding Screw: #10 - #22 AWG TSKK: Tubular Connector with Wire Protector Wire Termination Torque: 16 in. lbs
    Original PDF
    Product Data Sheet 6G38 TS C 3/8” Sectional
    Product Data Sheet 6G38 TS C 3/8” Sectional Terminal Block Channel Mount 50 Amps, 600 Volts (AC/DC) 32 Circuits Per Foot Copper Wire Only Wire Range with Wire Binding Screw: #8 - #18 AWG TS: Tubular Connector Wire Termination Torque: 16 in. lbs See table below for Wire Classes and torque
    Original PDF