Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    TYCO CRIMP HEIGHT SPECIFICATION Search Results

    TYCO CRIMP HEIGHT SPECIFICATION Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    HM1L52LDP242H2PLF
    Amphenol Communications Solutions Right Angle Signal Header, 60 Position Press-Fit, Specific Loading PDF
    HM1L52LDP242H6PLF
    Amphenol Communications Solutions Right Angle Signal Header, 60 Position Press-Fit, Specific Loading PDF
    10104321-009RLF
    Amphenol Communications Solutions Universal Contact, 3.50mm Height PDF
    10094594-009RLF
    Amphenol Communications Solutions Universal Contact, 1.30mm Height PDF
    10104321-001RLF
    Amphenol Communications Solutions Universal Contact, 3.50mm Height PDF

    Documents mentioning TYCO CRIMP HEIGHT SPECIFICATION

    Document Partial File Text Tags Type PDF
    applicators
    AMP-O-LECTRIC Model G Terminating Machine Fast Facts • Quieter • Improved guarding and lighting • Toolless changeover of applicators • Precision manual- or autoadjust for crimp height • Total and batch counter • Accepts all existing Tyco Electronics miniature
    Original PDF
    6051
    Application Specification AMPINNERGY* Wire- to- Wire (WTW) Connectors NOTE i 114-- 6051 11 DEC 09 Rev C All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2_.
    Original PDF
    m= — Tyco Electronics Application Specification
    m= — Tyco Electronics Application Specification 114-5250 01DEC09 Rev. C1 025 R eceptacle Contact The performance of applicable product is guaranteed only when processed by proper application tooling and condition described in this specification and/or TE recognized ones.
    OCR Scan PDF
    fakra
    Application Specification 114-- 13069 FAKRAh SMB 50- Ohm Inline Connectors NOTE i 01 MAR 10 Rev D All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2_.
    Original PDF
    Application Specification 114-13196 Euro-Crimp
    Application Specification 114-13196 Euro-Crimp Terminals and Splices NOTE i 01 MAY 07 Rev A All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters. Unless otherwise specified, dimensions have a tolerance of +0.13 and angles have a tolerance of +2 . Figures and
    Original PDF
    Application Specification 114-13013 2.8mm
    Application Specification 114-13013 2.8mm Terminal System (Sealed and Unsealed) NOTE 05 SEP 08 Rev C All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters. Unless _ otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2 . Figures and
    Original PDF
    Application Specification 114-- 1014 Miniature
    Application Specification 114-- 1014 Miniature Rectangular (MR) Contacts and Housings 11 DEC 09 Rev D All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2_.
    Original PDF
    Application Specification 114-16003 FFC Round
    Application Specification 114-16003 FFC Round Wire Pin and Receptacle Contacts NOTE i 16 MAY 08 Rev E All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2 .
    Original PDF
    114-16008
    Application Specification Flexible Flat Cable (FFC) 114-16008 Connectors for 1.27 mm [.050 in.] Centerline Cable NOTE i 02 MAR 09 Rev K All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2 .
    Original PDF
    Application Specification 114-- 13125 Coaxial
    Application Specification 114-- 13125 Coaxial Snap- Lock Connectors NOTE i 07 DEC 09 Rev D All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2_.
    Original PDF
    Application Specification AMPLIVAR* 114-2003
    Application Specification AMPLIVAR* 114-2003 9-Serration Pigtail Splice NOTE NOTE 13 JAN 05 Rev B All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2 .
    Original PDF
    Application Specification 114-2019 Cluster Block
    Application Specification 114-2019 Cluster Block Housings and Contacts 05 NOV 08 Rev F All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2 .
    Original PDF
    114-16015
    Application Specification Flexible Flat Cable (FFC) Housings with 114-16015 Contact Cavities on 2.54 mm [.100 in.] Centerline Spacing 10 DEC 07 Rev E All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and
    Original PDF
    Application Specification Wire- to- Board
    Application Specification Wire- to- Board Connector for Hermaphroditic Blade and Receptacle SMT Connectors NOTE i 114-- 13252 19 OCT 09 Rev D All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters. Unless
    Original PDF
    114-2025
    Application Specification 114-2025 FASTIN-FASTON* Tabs, Receptacles, and Housings NOTE i 01 AUG 07 Rev B All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2 .
    Original PDF
    Application Specification 114-- 9004 Twin Leaf
    Application Specification 114-- 9004 Twin Leaf Contacts NOTE i 18 SEP 09 Rev F All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2_.
    Original PDF
    Application Specification 114-- 1111 Mini-
    Application Specification 114-- 1111 Mini- Universal MATE- N- LOK* 2 Connectors NOTE i 08 FEB 10 Rev F All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2_.
    Original PDF
    Application Specification 114-13195 AMP-DUAC UPC
    Application Specification 114-13195 AMP-DUAC UPC Connectors NOTE i 27 APR 07 Rev A All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters. Unless otherwise specified, dimensions have a tolerance of +0.10 and angles have a tolerance of +1 . Figures and
    Original PDF
    Application Specification 114–13093 Open Barrel
    Application Specification 114–13093 Open Barrel Pigtail POWERSPLICE* Terminal NOTE NOTE 24 MAY 04 Rev B All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2 .
    Original PDF
    Application Specification 114-2146 AMPLIVAR*
    Application Specification 114-2146 AMPLIVAR* FASTIN-FASTON* Series 187 and 250 Tab Contacts NOTE i 12 JUN 07 Rev C All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2 .
    Original PDF
    Application Specification 114-- 10007 Type VI
    Application Specification 114-- 10007 Type VI Insulation Grip Contacts NOTE i 23 NOV 09 Rev C All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2_.
    Original PDF
    25006
    Application Specification Locking Clip 0.64- mm [.025- in.] Square Contacts and Housings NOTE i 114-- 25006 03 MAR 10 Rev F All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2_.
    Original PDF
    16022
    Application Specification 114-- 16022 High Current Pin and Socket Contacts NOTE i 07 DEC 09 Rev B All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2_.
    Original PDF
    Application Specification 114-- 2025 FASTIN-
    Application Specification 114-- 2025 FASTIN- FASTON* Tabs, Receptacles, and Housings NOTE i 13 AUG 09 Rev C All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2_.
    Original PDF
    Application Specification 114-- 40003 AMPLIMITE*
    Application Specification 114-- 40003 AMPLIMITE* HDE- 20 Contacts NOTE i 24 NOV 09 Rev B All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2_.
    Original PDF