Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    TRIPLE INSULATED WIRE Search Results

    TRIPLE INSULATED WIRE Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    5410/BCA
    Rochester Electronics LLC 5410 - NAND GATE, TRIPLE 3-INPUT - Dual marked (M38510/00103BCA) PDF Buy
    54L10/BDA
    Rochester Electronics LLC 54L10 - NAND GATE, TRIPLE 3-INPUT - Dual marked (M38510/02003BDA) PDF Buy
    5410/BDA
    Rochester Electronics LLC 5410 - NAND GATE, TRIPLE 3-INPUT - Dual marked (M38510/00103BDA) PDF Buy
    100331/VYA
    Rochester Electronics LLC 100331 - 100K Series, Low Power Triple D-Type Flip-Flop - Dual marked (5962-9153601VYA) - SPACE-LEVEL LOGIC PDF Buy
    MP-5XRJ11PPXS-014
    Amphenol Cables on Demand Amphenol MP-5XRJ11PPXS-014 Flat Silver Satin Modular Crossed wiring Cable, RJ11 / RJ11 14ft PDF

    TRIPLE INSULATED WIRE Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    triple insulated wire

    Abstract: transformer triple insulated
    Contextual Info: Switching Transformers Transformer with Triple Insulated Wire Type: Japan Singapore Indonesia HK TIW These transformers of layer winding are realized compact size, low height and lightweight by using triple insulated wire. Applied Safety Std. : Denki Yohin✽ , UL, CSA, IEC


    Original
    29t1w-1629t1w-1219tiw-829tiw-16+529tiw-12iec65iec950triple insulated wiretransformer triple insulated PDF

    triple insulated wire

    Abstract: transformer triple insulated
    Contextual Info: Switching Transformers Transformer with Triple Insulated Wire 7\SH Japan Singapore Indonesia HK 7,: Custom Designs for OEM Volume Applications 7KHVH WUDQVIRUPHUV using lD\HUed ZLQGLQJs feature compact sL]H ORZ KHLJKW DQG OLJKW wHLJKW due to use of triple insulated wLUH


    Original
    triple insulated wiretransformer triple insulated PDF

    triple insulated wire

    Abstract: SDT28 SDT33 SDT38 SDT42 100KMZ
    Contextual Info: ● Tr a n s f o r m e r ● Triple Insulated Wire type ◆Performance Output W F=100KMZ PINS SDT28 80 6✕6 SDT33 130 7✕7 SDT38 180 8✕8 SDT42 200 9✕9 Item Size ◆Features Triple insulated wire is used Small High efficieney Without barrier ◆Applications


    Original
    100kmzsdt28sdt33sdt38+2sdt42triple insulated wire PDF

    6242Y

    Abstract: CBBR0014 CBBR0015 CBBR0016 CBBR0017 CBBR0018 CBBR0019 CBBR0020 CBBR0021 6243Y
    Contextual Info: 6242Y & 6243Y Twin, Triple & Earth Mains Cables 6242Y 2-Core and Earth Features: • 2 core Red and Black PVC insulated plain copper conductors with a non-insulated earth wire. • Available with White or Grey outer sheath. Specifications Cross Section Area


    Original
    6242y6243ycbbr0014cbbr0015+6cbbr0016cbbr0017cbbr0018cbbr0019cbbr0020cbbr0021 PDF

    Series 805

    Contextual Info: Series 805 Series 805 Mighty Mouse Triple-Start ACME Thread Flexible, Lightweight Phantom Cable Cordsets General Information Series 805 Ultraflexible “Phantom Cable” Cordsets Phantom Cable cordsets feature high-flex rubber-insulated wires, lightweight


    Original
    100mhz1000mhzseries 805 PDF

    triple insulated wire

    Abstract: switching transformer winding transformer bobbin transformer triple insulated Denki mobile charger circuit Switching Transformers transformer triple FE16 transformer for mobile charger
    Contextual Info: Switching Transformers Transformers for charger Industry/Field: Mobile communication/Amusement Wider producut line High coupling transformers with triple insulated wire. • Development goals: For AC adaptor and Battery Charger • Features: Low loss and high performance


    Original
    ac100vv/50matriple insulated wireswitching transformer winding+8transformer bobbintransformer triple insulateddenkimobile charger circuitswitching transformerstransformer triplefe16transformer for mobile charger PDF

    siemens 3un6 thermistor

    Abstract: siemens 3UN9 3UN6 3UN9 PTC Thermistor of siemens motor Siemens 3UN6 siemens PTC thermistor B59355-M130-A70 B59355-M155-A70 B59355-M120-A70
    Contextual Info: Motor and Machine Protection B59355 M 355 Applications ● Thermal protection of winding in electric motors Features ● Thermistor pellets with insulating encapsulation in series connection triple sensor ● Silver-plated and Teflon(PTFE)-insulated AWG 26 litz wires


    Original
    b59355range-m90-a70b59355-m100-a70b59355-m110-a70+13b59355-m120-a70b59355-m130-a70b59355-m140-a70b59355-m145-a70b59355-m150-a70b59355-m155-a70siemens 3un6 thermistorsiemens 3un93un63un9ptc thermistor of siemens motorsiemens 3un6siemens ptc thermistor PDF

    CSC3130-X

    Abstract: TOP234Y TOP247y transformer TOP244Y 12N35
    Contextual Info: Flyback Power Transformer ELECTRONICS INC. EPC3130-X • Used in SMPS Flyback Topology • Designed for use with Power Integration Chip • Reinforced Insulation Triple Insulated Wire • UL 94V-0 Recognized Components • UL 1446 Class F Insulation System


    Original
    epc3130-xepc3130-1epc3130-2epc3130-3+10epc3130-4epc3130-5op249yop234yop247ycsc3130-xtop234ytop247y transformertop244y12n35 PDF

    Contextual Info: Flyback Power Transformer ELECTRONICS INC. EPC3127-X • Used in SMPS Flyback Topology • Designed for use with Power Integration Chip • Reinforced Insulation Triple Insulated Wire • UL 94V-0 Recognized Components • UL 1446 Class F Insulation System


    Original
    epc3127-xepc3127-2epc3127-3epc3127-4+5tny268ptny266pop232y/top242yop244ptny267 PDF

    TOP234Y

    Abstract: TOP247Y top249y TOP247y transformer CSC3130-X
    Contextual Info: Flyback Power Transformer ELECTRONICS INC. EPC3130-X • Used in SMPS Flyback Topology • Designed for use with Power Integration Chip • Reinforced Insulation Triple Insulated Wire • UL 94V-0 Recognized Components • UL 1446 Class F Insulation System


    Original
    epc3130-xepc3130-1epc3130-2epc3130-3+9epc3130-4op249yop234yop247ytop234ytop247ytop249ytop247y transformercsc3130-x PDF

    TOP249Y

    Abstract: top247y TOP234Y TOP247y transformer
    Contextual Info: Flyback Power Transformer ELECTRONICS INC. EPC3130-X • Used in SMPS Flyback Topology • Designed for use with Power Integration Chip • Reinforced Insulation Triple Insulated Wire • UL 94V-0 Recognized Components • UL 1446 Class F Insulation System


    Original
    epc3130-xepc3130-1epc3130-2epc3130-3+8epc3130-4op249yop234yop247ytop249ytop247ytop234ytop247y transformer PDF

    TOP244Y

    Abstract: TOP243P triple insulated wire smps transformer design smps wires TOP243 EPC3129-1 EPC3129-2 EPC3129-X EPC-31
    Contextual Info: Flyback Power Transformer ELECTRONICS INC. EPC3129-X • Used in SMPS Flyback Topology • Designed for use with Power Integration Chip • Reinforced Insulation Triple Insulated Wire • UL 94V-0 Recognized Components • UL 1446 Class F Insulation System


    Original
    epc3129-xepc3129-1epc3129-2op244y+9op243pcsc3129-xtop244ytop243ptriple insulated wiresmps transformer designsmps wirestop243epc-31 PDF

    TNY267

    Abstract: TNY268P TNY267 equivalent tny267 Transformer TNY266P TOP244P TNY266 10 amp smps flyback smps smps transformer design
    Contextual Info: Flyback Power Transformer ELECTRONICS INC. EPC3127-X • Used in SMPS Flyback Topology • Designed for use with Power Integration Chip • Reinforced Insulation Triple Insulated Wire • UL 94V-0 Recognized Components • UL 1446 Class F Insulation System


    Original
    epc3127-xepc3127-2epc3127-3epc3127-4+12tny268ptny266pop232y/top242yop244ptny267tny267 equivalenttny267 transformertop244ptny26610 amp smpsflyback smpssmps transformer design PDF

    TOP249Y

    Abstract: TOP234Y
    Contextual Info: Flyback Power Transformer ELECTRONICS INC. EPC3130-X • Used in SMPS Flyback Topology • Designed for use with Power Integration Chip • Reinforced Insulation Triple Insulated Wire • UL 94V-0 Recognized Components • UL 1446 Class F Insulation System


    Original
    epc3130-xepc3130-1epc3130-2epc3130-3+6op249yop234yop247ycsc3130-xtop249ytop234y PDF

    Contextual Info: Flyback Power Transformer ELECTRONICS INC. EPC3127-X • Used in SMPS Flyback Topology • Designed for use with Power Integration Chip • Reinforced Insulation Triple Insulated Wire • UL 94V-0 Recognized Components • UL 1446 Class F Insulation System


    Original
    epc3127-xepc3127-2epc3127-3epc3127-4+5tny268ptny266pop232y/top242yop244ptny267 PDF

    TNY268

    Abstract: schematic of tny268 TNY268 APPLICATION NOTE TNY267 tny268 Transformer tny267 Transformer TNY254 TOP242P smps using tny268 tny2* 7 pin
    Contextual Info: Flyback Power Transformer ELECTRONICS INC. EPC3133-X • Used in SMPS Flyback Topology • Designed for use with Power Integration Chip • Reinforced Insulation Triple Insulated Wire • UL 94V-0 Recognized Components • UL 1446 Class F Insulation System


    Original
    epc3133-xepc3133-1epc3133-2epc3133-3+15epc3133-4epc3133-5epc3133-6tny253op242ptny254tny268schematic of tny268tny268 application notetny267tny268 transformertny267 transformertop242psmps using tny268tny2* 7 pin PDF

    TNY264P

    Abstract: LNK501 100 kHz flyback transformer TOP221P tny2* 7 pin TNY264 XA MARKING CODE flyback transformer pin connections EPC3132-1A EPC3132-2A
    Contextual Info: Flyback Power Transformer ELECTRONICS INC. EPC3132-XA • Used in SMPS Flyback Topology • Designed for use with Power Integration Chip • Reinforced Insulation Triple Insulated Wire • UL 94V-0 Recognized Components • UL 1446 Class F Insulation System


    Original
    epc3132-xatny264pepc3132-1aepc3132-2a+10op221pepc3132-3alnk501epc3132-4a100 khz flyback transformertop221ptny2* 7 pintny264xa marking codeflyback transformer pin connections PDF

    tny2* 7 pin

    Abstract: TNY264P 100 kHz flyback transformer LNK501 TNY264 TOP221P 10 pin flyback transformer schematics TOP221 42KHZ
    Contextual Info: Flyback Power Transformer ELECTRONICS INC. EPC3132-X • Used in SMPS Flyback Topology • Designed for use with Power Integration Chip • Reinforced Insulation Triple Insulated Wire • UL 94V-0 Recognized Components • UL 1446 Class F Insulation System


    Original
    epc3132-xtny264pepc3132-1epc3132-2+11op221pepc3132-3lnk501epc3132-4tny2* 7 pin100 khz flyback transformertny264top221p10 pin flyback transformer schematicstop22142khz PDF

    CSC3130-X

    Abstract: TOP249 TOP247y transformer TOP249Y 12N35
    Contextual Info: Flyback Power Transformer ELECTRONICS INC. EPC3130-X • Used in SMPS Flyback Topology • Designed for use with Power Integration Chip • Reinforced Insulation Triple Insulated Wire • UL 94V-0 Recognized Components • UL 1446 Class F Insulation System


    Original
    epc3130-xepc3130-1epc3130-2epc3130-3+10epc3130-4epc3130-5op249yop234yop247ycsc3130-xtop249top247y transformertop249y12n35 PDF

    tny267 Transformer

    Abstract: TNY267 TNY268P top244p EPC3127-X
    Contextual Info: Flyback Power Transformer ELECTRONICS INC. EPC3127-X • Used in SMPS Flyback Topology • Designed for use with Power Integration Chip • Reinforced Insulation Triple Insulated Wire • UL 94V-0 Recognized Components • UL 1446 Class F Insulation System


    Original
    epc3127-xepc3127-1epc3127-2epc3127-3+8epc3127-4tny268ptny266pop232y/top242yop244ptny267tny267 transformertop244p PDF

    TOP234Y

    Abstract: VIPER 27 TOP249Y TOP247Y TOP244Y ST VIPER 27 TOP247y transformer viper flyback transformer viper 100 Viper 15
    Contextual Info: Flyback Power Transformer ELECTRONICS INC. EPC3130-X • Used in SMPS Flyback Topology • Designed for use with Power Integration Chip • Reinforced Insulation Triple Insulated Wire • UL 94V-0 Recognized Components • UL 1446 Class F Insulation System


    Original
    epc3130-xop249yop234yop247y+14op244yepc3130-1epc3130-2epc3130-32top234yviper 27top249ytop247ytop244yst viper 27top247y transformerviper flyback transformerviper 100viper 15 PDF

    Contextual Info: Flyback Power Transformer ELECTRONICS INC. EPC3132-X • Used in SMPS Flyback Topology • Designed for use with Power Integration Chip • Reinforced Insulation Triple Insulated Wire • UL 94V-0 Recognized Components • UL 1446 Class F Insulation System


    Original
    epc3132-xtny264pepc3132-1epc3132-2+4op221pepc3132-3lnk501epc3132-4 PDF

    EF25 transformer

    Abstract: etd39 core type smps full bridge transformer design Nyleze AN-16 topswitch EF20 TRANSFORMER epoxylite 203 TDK EF25 EPOXYLITE 814 EE19 TDK Ferrite Core PC40 EFD20 TDK Ferrite Core PC40
    Contextual Info: TOPSwitch Flyback Transformer Construction Guide ® Application Note AN-18 Introduction Ferrite Core Manufacturer’s Catalogs This application note is a design and construction guide for margin wound or triple insulated wire wound flyback transformers suitable for use with TOPSwitch. Margin wound


    Original
    an-18an-16ef25 transformeretd39 core type smps full bridge transformer design+8nylezean-16 topswitchef20 transformerepoxylite 203tdk ef25epoxylite 814ee19 tdk ferrite core pc40efd20 tdk ferrite core pc40 PDF

    EPC3130-X

    Abstract: TOP249Y "12-pin" flyback smps TOP247Y TOP234Y viper 100 TOP244Y viper flyback transformer TOP234 TOP247y transformer
    Contextual Info: Flyback Power Transformer ELECTRONICS INC. EPC3130-X[-S] & EPC3130-X[-S]-LF • Used in SMPS Flyback Topology • Designed for use with Power Integration Chip • Reinforced Insulation Triple Insulated Wire • Add “-LF” after part number for Lead-Free


    Original
    epc3130-xepc3130-1epc3130-2-s-lfcsc3130-x+9top249y12-pin" flyback smpstop247ytop234yviper 100top244yviper flyback transformertop234top247y transformer PDF