Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    TRIODE RS 1 Search Results

    TRIODE RS 1 Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    LM3445MX/NOPB
    Texas Instruments Triac Dimmable Offline LED Driver 14-SOIC Visit Texas Instruments Buy
    LM3445MMX/NOPB
    Texas Instruments Triac Dimmable Offline LED Driver 10-VSSOP -40 to 125 Visit Texas Instruments Buy
    LM3445MM/NOPB
    Texas Instruments Triac Dimmable Offline LED Driver 10-VSSOP -40 to 125 Visit Texas Instruments Buy
    LM3445M/NOPB
    Texas Instruments Triac Dimmable Offline LED Driver 14-SOIC Visit Texas Instruments Buy
    AM26C31IDRE4
    Texas Instruments Quadruple differential line driver 16-SOIC -40 to 85 Visit Texas Instruments Buy

    Documents mentioning TRIODE RS 1

    Document Partial File Text Tags Type PDF
    rs 3026 cl
    INDUSTRIAL RF HEATING RS 3026 CL Water-cooled triode 32 kW Output power: 32 kW in CW mode Anode voltage: 12 kV Anode dissipation: 15 kW max. Frequency up to 120 MHz INDUSTRIAL RF HEATING The RS 3026 CL is a RF power triode designed specifically for industrial
    Original PDF
    rs 3005 cl
    INDUSTRIAL RF HEATING RS 3005 CL Forced-air cooled triode 6 kW Output power: 6 kW in CW mode Anode voltage: 7.2 kV Anode dissipation: 2.5 kW max. Frequency up to 160 MHz INDUSTRIAL RF HEATING The RS 3005 CL is a RF power triode designed specifically for industrial
    Original PDF
    triode
    INDUSTRIAL RF HEATING RS 3150 CJ Water-cooled triode 240 kW Output power: 240 kW in CW mode Anode voltage: 15 kV Anode dissipation: 100 kW max. Frequency up to 100 MHz INDUSTRIAL RF HEATING The RS 3150 CJ is a RF power triode designed specifically for industrial
    Original PDF
    3060 cl
    INDUSTRIAL RF HEATING RS 3060 CL Forced-air cooled triode 120 kW Output power: 120 kW in CW mode Anode voltage: 14 kV Anode dissipation: 35 kW max. Frequency up to 100 MHz INDUSTRIAL RF HEATING The RS 3060 CL is a RF power triode designed specifically for industrial
    Original PDF
    INDUSTRIAL RF HEATING RS 3005 CJ Water-cooled
    INDUSTRIAL RF HEATING RS 3005 CJ Water-cooled triode 6 kW Output power: 6 kW in CW mode Anode voltage: 7.2 kV Anode dissipation: 2.5 kW max. Frequency up to 160 MHz INDUSTRIAL RF HEATING The RS 3005 CJ is a RF power triode designed specifically for industrial
    Original PDF
    rf heating
    INDUSTRIAL RF HEATING RS 3040 CJ Water-cooled triode 60 kW Output power: 60 kW in CW mode Anode voltage: 14 kV Anode dissipation: 35 kW max. Frequency up to 100 MHz INDUSTRIAL RF HEATING The RS 3040 CJ is a RF power triode designed specifically for industrial
    Original PDF
    power triode
    INDUSTRIAL RF HEATING RS 3020 CJ Water-cooled triode 20 kW Output power: 20 kW in CW mode Anode voltage: 12 kV Anode dissipation: 20 kW max. Frequency up to 120 MHz INDUSTRIAL RF HEATING The RS 3020 CJ is a RF power triode designed specifically for industrial
    Original PDF
    rs 3060 cj
    INDUSTRIAL RF HEATING RS 3060 CJ Water-cooled triode 120 kW Output power: 120 kW in CW mode Anode voltage: 14 kV Anode dissipation: 40 kW max. Frequency up to 100 MHz INDUSTRIAL RF HEATING The RS 3060 CJ is a RF power triode designed specifically for industrial
    Original PDF
    rs 3500
    INDUSTRIAL RF HEATING RS 3500 CJ Water-cooled triode 750 kW Output power: 750 kW in CW mode Anode voltage: 18 kV Anode dissipation: 300 kW max. Frequency up to 30 MHz INDUSTRIAL RF HEATING The RS 3500 CJ is a RF power triode designed specifically for industrial
    Original PDF
    INDUSTRIAL RF HEATING RS 3080 CL Forced-air
    INDUSTRIAL RF HEATING RS 3080 CL Forced-air cooled triode 120 kW Output power: 120 kW in CW mode Anode voltage: 14 kV Anode dissipation: 45 kW max. Frequency up to 100 MHz INDUSTRIAL RF HEATING The RS 3080 CL is a RF power triode designed specifically for industrial
    Original PDF
    INDUSTRIAL RF HEATING RS 3040 CL Forced-air
    INDUSTRIAL RF HEATING RS 3040 CL Forced-air cooled triode 60 kW Output power: 60 kW in CW mode Anode voltage: 14 kV Anode dissipation: 25 kW max. Frequency up to 100 MHz INDUSTRIAL RF HEATING The RS 3040 CL is a RF power triode designed specifically for industrial
    Original PDF
    rs 3021 cj
    INDUSTRIAL RF HEATING RS 3021 CJ Water-cooled high-µ triode 20 kW Output power: 20 kW in CW mode Anode voltage: 14 kV Anode dissipation: 20 kW max. Frequency up to 120 MHz INDUSTRIAL RF HEATING The RS 3021 CJ is a RF power high- amplification factor triode designed
    Original PDF
    industrial rf heating
    INDUSTRIAL RF HEATING RS 3061 CJ Water-cooled high-µ triode 110 kW Output power: 110 kW in CW mode Anode voltage: 15 kV Anode dissipation: 50 kW max. Frequency up to 100 MHz INDUSTRIAL RF HEATING The RS 3061 CJ is a RF power high- amplification factor triode designed
    Original PDF
    ech81
    ECH81 TRIO DE-HEPTO DE Triode-heptode. Heptode section intended fo r use as m ixer, R .F . - or I . F . a m ­ p lifie r. Triode section intented for use as o scilla to r in A .M ./F .M . re ce iv e rs. QUICK REFERENCE DATA Triode section la 1 3 .5 S 3 .7
    OCR Scan PDF
    E C H 83 MAINTENANCE TYPE TRIODE-HEPTODE
    E C H 83 MAINTENANCE TYPE TRIODE-HEPTODE Triode-heptode intended for use as m ixer in ca r radio sets and as sync sep a­ rator in TV re c e iv e rs . QUICK REFERENCE DATA Triode Anode voltage Va Anode current 25 1 2 .6 6 .3 V la 2 0 .7 5 0 .3 mA Transconductance
    OCR Scan PDF
    ecf200
    ECF200 TRIODE-PENTODE Triode-pentode intended fo r use in television re ce iv e rs; triode sectio n as lim it­ e r , noise d etector, A .G .C . am plifier, sync, separator and p u lse-am p lifier; pentode section as sound I . F . am plifier and video I . F . am plifier.
    OCR Scan PDF
    pd510
    PD510 SHUNT STABILIZER TRIODE Shunt stab ilizer triode intended for use in colour TV re c e iv e rs . HEATING: Indirect by A .C . or D .C .; serie s supply Heater current Vf Heater voltage 300 7. 3 DIMENSIONS AND CONNECTIONS Dimensions in mm. mA V Base: Magnoval
    OCR Scan PDF
    6562
    6562 FIXED-TUNED OSCILLATOR TRIODE "P e n c il T y p e ” W ith In te gra l R e so n a to rs For Radiosonde Se rvice at 1680 Me TENTATIVE RCA-6562 quency is a fixed-tuned, oscillator construction triode and intended service Ü A in is transm itting I t h a s t wo
    OCR Scan PDF
    ecc189
    ECC189 R.F. DOUBLE TRIODE Double triode with variable transconductance intended for use as V .H .F . c a scode am plifier in television re c e iv e rs. HEATING: Indirect by A .C . or D .C .; p arallel supply H eater voltage H eater cu rren t If LIMITING VALUES (Design centre rating system )
    OCR Scan PDF
    pcf201
    PCF201 TR IO D E -P E N TO D E Triode pentode intended for use in T .V . re c e iv e rs; triode section as lineblocking oscillator, part of a m ultivibrator, sync separator, pulse am plifier or A .G .C . delay diode; pentode section with rem ote cut-off as video I . F . am ­
    OCR Scan PDF
    tic44
    TYPES TIC44, TIC45. TIC46, TIC47 P-N-P-N PLANAR SILICON REVERSE-BLOCKING TRIODE THYRISTORS a■oo -j C< SILECTt THYRISTO RSÎ 600 mA DC • 30 thru 200 VOLTS r r- m >m <« OHH cnZO Rugged, One-Piece Construction with Standard TO-18 100-mil Pin-Circle Configuration
    OCR Scan PDF
    pc92
    PC92 MAINTENANCE TYPE H.F. TRIODE T riode intended for use as H .F . am plifier, o scillato r, m ixer and in fram e deflection c irc u its and line deflection circ u its of TV re c e iv e rs . QUICK REFERENCE DATA Anode cu rren t la 12 T ransconductance S
    OCR Scan PDF
    S ilic o n C ontrolled Rectifiers Reverse B lo c
    S ilic o n C ontrolled Rectifiers Reverse B lo c k in g Triode Th yristo rs… de signed for industrial and consum er applications such as pow er supplies; battery chargers; temperature, motor, light and welder controls. • Econom ical for a W ide Range of U se s
    OCR Scan PDF
    an-305
    IÖ R CALCULATION OF CURRENT RATING AN-305 INTERNATIONAL RECTIFIER / I P P U C M T O N N O T E CALCULATION OF RECTANGULAR WAVEFORM CURRENT RATING OF THYRISTO RS Most data sheets for reverse blocking, triode, power thyris­ tors (silicon controlled rectifiers) give current ratings only
    OCR Scan PDF
    pc900
    PC900 V.H .F. TRIODE T riode intended for use as R .F . am plifier in V .H .F . television re c e iv e rs. Cathode cu rren t T ransconductance Am plification factor QUICK REFERENCE DATA HEATING: Indirect by A .C . or D .C .; se rie s supply H eater cu rren t
    OCR Scan PDF