TRIGGER TRANSFORMER Search Results
TRIGGER TRANSFORMER Result Highlights (5)
Part | ECAD Model | Manufacturer | Description | Download | Buy |
---|---|---|---|---|---|
54F14/BCA |
![]() |
54F14 - Hex Inverter Schmitt Trigger |
![]() |
||
54F14/B2A |
![]() |
54F14 - Hex Inverter Schmitt Trigger |
![]() |
||
5414/BDA |
![]() |
5414 - Hex Inverter, Schmitt Trigger - Dual marked (M38510/15102BDA) |
![]() |
||
5414/BCA |
![]() |
5414 - Hex Inverter, Schmitt Trigger - Dual marked (M38510/15102BCA) |
![]() |
||
54LS113FM/B |
![]() |
54LS113 - Dual JK Neg-Edge-Triggered Flip-Flop w/preset |
![]() |
TRIGGER TRANSFORMER Datasheets Context Search
Catalog Datasheet | Type | Document Tags | |
---|---|---|---|
Contextual Info: MA785A Trigger Transformer for Spark Gaps DESCRIPTION The MA785A is a compact trigger transformer designed for triggering spark gaps. FEATURES * Trigger voltage up to 40 kV * Fast rise time – pulses up to 30 kV/ms * Flame retardant – approved to UL94 V-2 |
Original |
MA785A MA785A NY10523-1482 A1A-MA785A | |
FSR630
Abstract: FSR660 pc817 fairchild FAN480X FCP20N60 FAN6210MY JESD22-A114 zd 5.6v uf1007 DIODE pc817 dual
|
Original |
FAN6210 FAN6210 FSR660/630. FSR630 FSR660 pc817 fairchild FAN480X FCP20N60 FAN6210MY JESD22-A114 zd 5.6v uf1007 DIODE pc817 dual | |
Contextual Info: Solid State ReIays ISOLATING TRANSFORMER CONTROL DC-AC CONVERTER TRIAC LOAD TRIGGER CIRCUIT Figure 1. Hybrid SSR Figure 2. Transformer-Coupled SSR AC POWER PHOTO-TRANSISTOR REED RELAY TRIAC CONTROL SIGNAL OPTIONAL PREAMPLIFIER LED LOAD CONTROL SIGNAL TRIGGER |
Original |
60-Hz Z-127 | |
trigger transformerContextual Info: FETCO TYPE FTT ELECTRa TUCHNIK Trigger Transformer Schematic 1 Pri. 2 Features: • • 3 Sec. 4 Variations: • Applications include Laser firing circuits • choice of terminals and terminal location • Designed for low cost trigger source isolation in |
Original |
1500Dimensions trigger transformer | |
Contextual Info: PT-50 Vishay Dale Through Hole Transformers Trigger, SCR Isolation FEATURES • Designed for low-cost trigger source isolation in SCR power control circuits • Small physical size and low profile provide packaging advantages • Designed to transfer high amplitude or long duration |
Original |
PT-50 PT-20 2002/95/EC 2002/95/EC. 2002/95/EC 2011/65/EU. JS709A 02-Oct-12 | |
transformer dash 2 b-5Contextual Info: MODELS PT-10 and PT-20 Transformers Pulse, Trigger Type FEATURES • Choice of printed circuit or bobbin-type configurations • Designed to transfer high amplitude or long duration pulses without saturation • Designed for low-cost trigger source isolation in half and |
OCR Scan |
PT-10 PT-20 transformer dash 2 b-5 | |
Trigger Units
Abstract: OPTOCOUPLER for thyristor gate OPTOCOUPLER thyristor thyristor using zero crossing circuit 690VRMS Optocoupler with thyristor thyristor using zero crossing thyristor k2 k2 VDE0884 3 phase thyristor dc drive
|
Original |
690Vrms. Trigger Units OPTOCOUPLER for thyristor gate OPTOCOUPLER thyristor thyristor using zero crossing circuit 690VRMS Optocoupler with thyristor thyristor using zero crossing thyristor k2 k2 VDE0884 3 phase thyristor dc drive | |
Contextual Info: PT-50 Vishay Dale Through Hole Transformers Trigger, SCR Isolation FEATURES • Designed for low-cost trigger source isolation in SCR power control circuits • Small physical size and low profile provide packaging advantages • Designed to transfer high amplitude or long duration |
Original |
PT-50 11-Mar-11 | |
trigger transformer
Abstract: Design Considerations for Triggering of Flashlamp tr-180b TR-2298 PerkinElmer spark gap spark gap trigger transformer PerkinElmer 1795 40kv transformer PerkinElmer Optoelectronics tr-1855 TR-132C
|
Original |
||
Contextual Info: r-N SCR ISOLATION TRIGGER TRANSFORMER MODEL PT50 FEATURES • Designed for low-cost trigger source isolation in SCR Power Control Circuits • Small physical size and low profile provide packaging advantages Designed to transfer high amplitude or long duration pulses without saturation. |
OCR Scan |
||
Contextual Info: MODEL PT-50 Transformers Trigger, SCR Isolation FEATURES • Designed for low-cost trigger source isolation in SCR Power Control Circuits • Small physical size and low profile provide packaging advantages • Designed to transfer high amplitude or long duration pulses without saturation |
OCR Scan |
PT-50 PT-20 | |
PT50110
Abstract: DALE PT 30 PT50101
|
Original |
PT-50 2011/65/EU 2002/95/EC. 2002/95/EC 2011/65/EU. 12-Mar-12 PT50110 DALE PT 30 PT50101 | |
Contextual Info: MODEL PT-50 Transformers Trigger, SCR Isolation FEATURES • Designed for low-cost trigger source isolation in SCR power control circuits • Small physical size and low profile provide packaging advantages • Designed to transfer high amplitude or long duration pulses without saturation |
OCR Scan |
PT-50 PT-20 | |
VISHAY diode MARKING EB
Abstract: transformer dash 2 b-5 PT-10 PT-20 motor speed ratio polyurethane
|
Original |
PT-10 PT-20 11-Mar-11 VISHAY diode MARKING EB transformer dash 2 b-5 PT-20 motor speed ratio polyurethane | |
|
|||
SCR POWER CONTROL
Abstract: "scr power control" scr 106 DALE transformers PT-20 PT-50 dash transformer
|
Original |
PT-50 PT-20 29-Apr-99 SCR POWER CONTROL "scr power control" scr 106 DALE transformers PT-50 dash transformer | |
SCR TRIGGER PULSE TRANSFORMER
Abstract: ac motor speed control with scr DALE PULSE TRANSFORMER PT-10 PT-20
|
Original |
PT-10 PT-20 11-Dec-02 SCR TRIGGER PULSE TRANSFORMER ac motor speed control with scr DALE PULSE TRANSFORMER PT-20 | |
transformer dash 2 b-5
Abstract: 0/transformer dash 2 b-5 PT-10 PT-20
|
Original |
PT-10 PT-20 08-Apr-05 transformer dash 2 b-5 0/transformer dash 2 b-5 PT-20 | |
DALE transformersContextual Info: PT-50 Vishay Dale Transformers Trigger, SCR Isolation FEATURES • Designed for low-cost trigger source isolation in SCR power control circuits. • Small physical size and low profile provide packaging advantages. • Designed to transfer high amplitude or long duration pulses without saturation. |
Original |
PT-50 PT-20 08-Apr-05 DALE transformers | |
0/transformer dash 2 b-5Contextual Info: PT-50 Vishay Dale Transformers Trigger, SCR Isolation FEATURES • Designed for low-cost trigger source isolation in SCR power control circuits. • Small physical size and low profile provide packaging advantages. RoHS • Designed to transfer high amplitude or long duration pulses without saturation. |
Original |
PT-50 PT-20 08-Apr-05 0/transformer dash 2 b-5 | |
transformer dash 2 b-5Contextual Info: Models PT-10 and PT-20 Vishay Dale Transformers Pulse, Trigger Type FEATURES • Choice of printed circuit or bobbin-type configurations. • Designed to transfer high amplitude or long duration pulses without saturation. RoHS COMPLIANT • Designed for low-cost trigger source isolation in |
Original |
PT-10 PT-20 08-Apr-05 transformer dash 2 b-5 | |
trigger transformerContextual Info: High Voltage Trigger Transformer ELECTRONICS INC. EPC3215G-X • Used as Trigger Transformer in Photoflash Circuits • Operating Temperature : -40°C to +85°C • UL 94V-0 Recognized Components Actual Size • UL 1446 Class B Insulation System Electrical Parameters @ 25° C |
Original |
EPC3215G-X EPC3215G-1 EPC3215G-2 CSC3215G-X trigger transformer | |
trigger transformer
Abstract: trigger transformer layout EPC3215G-3 EPC3215G-X EPC3215G-1 EPC3215G-2 94v0 schematic
|
Original |
EPC3215G-X EPC3215G-1 EPC3215G-2 EPC3215G-3 CSC3215G-X trigger transformer trigger transformer layout EPC3215G-3 EPC3215G-X EPC3215G-1 EPC3215G-2 94v0 schematic | |
PT10
Abstract: transformer dash 2 b-5 PT-10 PT-20
|
Original |
PT-10 PT-20 18-Jul-08 PT10 transformer dash 2 b-5 PT-20 | |
scr 106
Abstract: scr power controls schematic diagram for heater schematic diagram for SCR controls heater SCR POWER CONTROL PT-20 PT-50
|
Original |
PT-50 PT-20 11-Dec-02 scr 106 scr power controls schematic diagram for heater schematic diagram for SCR controls heater SCR POWER CONTROL PT-50 |