Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    TRANSFORMER 6100 Search Results

    Documents mentioning TRANSFORMER 6100

    Document Partial File Text Tags Type PDF
    EER Cores ʳ EER Cores Application z z z z Shapes
    EER Cores ʳ EER Cores Application z z z z Shapes Driver transformer. Power Inductor. Power transformer. Wideband transformer. G A H 2 C Dimensions and Characteristics AL (nH/N2) Magnetic Dimensions Mechanical Dimensions (mm) EER 9.5x2.45 11x2.45 14.5x2.95
    Original PDF
    VAR 6503 Manual variable transformer Integrated
    VAR 6503 Manual variable transformer Integrated function unit to Modula system Simulation of under- and overvoltages Power line dips to arbitrary levels Complies with EN/IEC 61000-4-11 Connection for external DVM Sturdy design with industrial connectors The manually operated variable transformer
    Original PDF
    coreless
    DRIVER ICS Coreless Transformer Provides Innovative Features The expansion of the EiceDRIVER-family Coreless transformer technology was introduced in the market by Infineon Technologies in 2003 [1, 2] as a core technology for IGBT gate drive ICs. Coreless transformer technology may be either used to replace half-bridge drivers, which use level shifters, or to
    Original PDF
    Trafo_Ventilatoren_englisch:Trafo_Ventilatoren_eng
    Trafo_Ventilatoren_englisch:Trafo_Ventilatoren_englisch.qxd 04.06.2008 15:54 AC / EC Transformer Fans The engineer’s choice Seite 1 Version 05/2007 Trafo_Ventilatoren_englisch:Trafo_Ventilatoren_englisch.qxd 04.06.2008 15:54 Seite 2 The new AC / EC transformer fans from ebm-papst
    Original PDF
    Technical reference manual Transformer protection
    Technical reference manual Transformer protection terminal RET 521*2.5 7HFKQLFDO UHIHUHQFH PDQXDO ProtectIT Transformer protection terminal RET 521*2.5 $ERXW WKLV PDQXDO DocID: 1MRK 504 036-UEN Issue date: December 2003 Revision: - © Copyright 2003 ABB. All rights reserved.
    Original PDF
    SR Transformer Management RelayTM 4 High-speed,
    SR Transformer Management RelayTM 4 High-speed, multi-processor based relay for primary transformer protection and management. Features and Benefits Protection and Control ■ High-speed, multi-processor, three-phase ■ Two or three-winding ■ Adaptive relaying features
    Original PDF
    Transformer protection terminal RET 521*2.1 1MRK
    Transformer protection terminal RET 521*2.1 1MRK 504 012-BEN Page 1 Issued May 1999 Changed since March 1999 Data subject to change without notice (SE960158) Features • Multiple function transformer protection terminal in a compact design - Overexcitation restraint with 5th harmonic
    Original PDF
    001-ben
    JL » 1 1 n i p » Transformer protection terminal RET 521 1MRK 504 001-BEN Page 1 Issued June 1998 Changed since April 1998 Data subject to change without notice (SE960158) Features Multiple function transformer protection ter­ minal in a compact design
    OCR Scan PDF
    an854
    AN854 Connecting a PICmicro® Microcontroller to a Standard Analog Telephone Line Author: Figure 1 shows how the ring and tip lines run into the primary of a transformer. The hookswitch on the line side of the transformer is not shown but can be implemented with opto-couplers, relays or switches. When a
    Original PDF
    3URWHFW,7 7UDQVIRUPHU SURWHFWLRQ WHUPLQDO 5(7
    3URWHFW,7 7UDQVIRUPHU SURWHFWLRQ WHUPLQDO 5(7 +79 1MRK 504 047-BEN Page 1 Issued: June 2004 Revision: Data subject to change without notice )HDWXUHV • Pre-configured transformer terminal for cost-effective engineering and commissioning • Multiple function transformer protection terminal in a compact design
    Original PDF
    32824
    TITLE TRANSFORMER, ADSL CUSTOMER PREMISE PART NUMBER AGENCY APPROVAL: BABT CERT # : 610066 UL #: E145198 1000 PARKERS LAKE ROAD WAYZATA. MN 55391 (952) 475-1173 REV H 32824 PAGE 1 END SPECIFICATIONS TEMP CLASS 105°C DESIGNED TO MEET UL1950/IEC-950 REQUIREMENTS
    Original PDF
    TITLE TRANSFORMER, ADSL CP SCHOTT CORPORATION
    TITLE TRANSFORMER, ADSL CP SCHOTT CORPORATION PART NUMBER AGENCY APPROVAL: BABT CERT #610066 UL E145198 1000 PARKERS LAKE ROAD WAYZATA, MN 55391 REV E 34318 PAGE inches (mm) SPECIFICATIONS TEMP CLASS 105°C DESIGNED TO MEET UL 1950/IEC-950 REQUIREMENTS WORKING VOLTAGE 250 VRMS, SUPPLEMENTARY INSULATION
    Original PDF
    tisp7015
    www.bourns.com Bourns Announces New Additions to Product Palette TISP4500H3 Single bidirectional overvoltage protector developed for transformer coupled xDSL applications… Page 2 TISP7015, TISP7038 Low Voltage Triple Element TISP® products designed to protect
    Original PDF
    Product catalogue | Electronics | Analogue signal
    Product catalogue | Electronics | Analogue signal conditioning | Frequency signal isolator/converter | f/DC isolating transformer General ordering data Order No. Part designation Version EAN Qty. Input Max. voltage Rated input level Input frequency Sensor
    Original PDF
    Product catalogue | Electronics | Analogue signal
    Product catalogue | Electronics | Analogue signal conditioning | Frequency signal isolator/converter | f/DC isolating transformer General ordering data Order No. Part designation Version EAN Qty. Input Max. voltage Rated input level Input frequency Sensor
    Original PDF
    TISP4290J3BJ THRU TISP4395J3BJ BIDIRECTIONAL
    TISP4290J3BJ THRU TISP4395J3BJ BIDIRECTIONAL THYRISTOR OVERVOLTAGE PROTECTORS TISP4xxxJ3BJ Overvoltage Protector Series Ion-Implanted Breakdown Region -Precise and Stable Voltage -Low Voltage Overshoot Under Surge SMB Package (Top View) Designed for Transformer Center Tap (Ground Return)
    Original PDF
    tisp4290j3bj
    TISP4290J3BJ THRU TISP4395J3BJ BIDIRECTIONAL THYRISTOR OVERVOLTAGE PROTECTORS TISP4xxxJ3BJ Overvoltage Protector Series Ion-Implanted Breakdown Region -Precise and Stable Voltage -Low Voltage Overshoot Under Surge SMB Package (Top View) Designed for Transformer Center Tap (Ground Return)
    Original PDF
    Technical reference manual RET 521*2.3
    Technical reference manual RET 521*2.3 Transformer protection terminal Contents Chapter Functional description Page 3 Design description 267 References 303 Index 305 Customer feedback report 309 Example configurations 311 Service Notes 453 2 Functional description
    Original PDF
    33818
    TITLE TRANSFORMER ADSL CUSTOMER PREMISE 33818 PN AGENCY APPROVAL: UL - E145198, BABT CERT 610066 SPECIFICATIONS: 2 OF 6 .560 MAX (14.22) TEMP CLASS 105°C Designed to meet UL1950/IEC-950 Requirements Working voltage 250 Vrms, Supplementary Insulation. 1. INDUCTANCE: @ 0.1 Vrms, 10 KHz, 1-4 = 1.425 TO 1.575 mH
    Original PDF
    Product catalogue | Functional Electronics |
    Product catalogue | Functional Electronics | Monitoring modules | Current monitoring | Analogue output General ordering data Order No. Part designation Version EAN Qty. 8662140000 CMA 100/5A Current transformer, 100 A AC , 1 , 5 A AC , 1 , Screw connection (secondary)
    Original PDF