    CS-DNPDM6MMX2-006
    Amphenol Cables on Demand Amphenol CS-DNPDM6MMX2-006 Premium 6-pin Mini-DIN 6 (MD6) Cable - Mini-DIN 6 Male to Mini-DIN 6 Male 6ft PDF
    68305-001LF
    Amphenol Communications Solutions Din Accessory Coding PDF
    65175-002LF
    Amphenol Communications Solutions Din Accessory Cover PDF
    85451-001LF
    Amphenol Communications Solutions Din Accessory Guide PDF
    BPBS8B96CAP2LF
    Amphenol Communications Solutions Din Accessory Cover set PDF

    Documents mentioning TIMER DIN VDE 011

    Document Partial File Text Tags Type PDF
    FF-SRST Emergency Stop Module with Timer FEATURES
    FF-SRST Emergency Stop Module with Timer FEATURES • Complies with the Machinery Directive for 98/37/EC, IEC 204, EN 60204, DIN VDE 0113 and UL 508 • Dual channel input • Safety outputs: two direct NO contacts, one direct NC contact, two NO delayed contacts and one NC delayed contact
    Original PDF
    sza 52-s
    Timer and switching relays ON-delay SZA 52-S / SZA 52 / SZAN 52-S / SZA 54-2S interface ON-delay multi-range electromechanical timer relay • Devices for single voltage • Function: ON-delay (AV), SZAN 52-S protected against power failure • 1 setting range divided into 6 time ranges
    Original PDF
    Electronic timer CT-VWD Impulse-ON with 1 c/o
    Electronic timer CT-VWD Impulse-ON with 1 c/o contact Data sheet Characteristics CT-VWD 1 7 selectable time ranges, from 0.05 s to 100 h, for the adjustment of the pulse time 2 Potentiometer with direct reading scale for the fine adjustment of the pulse time
    Original PDF
    Fail-Safe Delay Timer AZS 2305 AC / DC-Version ■3
    Fail-Safe Delay Timer AZS 2305 AC / DC-Version ■3 Enabling paths General information The fail-safe delay tim er AZS 2305 has the following features: • Fail-safe monitoring of a set time value • Adjustable time from 0.1 s to 99 min • Compatible with SCHMERSAL s safety com ponents
    OCR Scan PDF
    39584 GE Consumer & Industrial Power Protection
    39584 GE Consumer & Industrial Power Protection GE Consumer & Industrial Power Protection (formerly GE Power Controls), a division of GE Consumer & Industrial, is a first class European supplier of low-voltage products including wiring devices, residential and industrial electrical
    Original PDF
    Electronic timer CT-VWD.12 2CDC 251 095 F0t06
    Electronic timer CT-VWD.12 2CDC 251 095 F0t06 Impulse-ON with 1 c/o contact Data sheet Features �  Rated control supply voltage 24‑48 V DC, 24‑240 V AC Single‑function timer impulse‑ON 7 time ranges (0.05 s ‑ 100 h) in one device
    Original PDF
    Electronic timer CT-ERD.12 2CDC 251 092 F0t06
    Electronic timer CT-ERD.12 2CDC 251 092 F0t06 ON-delayed with 1 c/o contact Data sheet Features �  Rated control supply voltage 24‑48 V DC, 24‑240 V AC Single‑function timer ON‑delay 7 time ranges (0.05 s ‑ 100 h) in one device
    Original PDF
    Electronic timer CT-EBD.12 2CDC 251 096 F0t06
    Electronic timer CT-EBD.12 2CDC 251 096 F0t06 Flasher starting with ON with 1 c/o contact Data sheet Features �  Rated control supply voltage 24‑48 V DC, 24‑240 V AC Single‑function timer flasher, starting with ON
    Original PDF
    Electronic timer CT-ERD.22 2CDC 251 091 F0t06
    Electronic timer CT-ERD.22 2CDC 251 091 F0t06 ON-delayed with 2 c/o contacts Data sheet Features �  Rated control supply voltage 24‑48 V DC, 24‑240 V AC Single‑function timer ON‑delay 7 time ranges (0.05 s ‑ 100 h) in one device
    Original PDF
    SUB M INIA TURE TIM ER Two tim ed contacts ZAR 2
    SUB M INIA TURE TIM ER Two tim ed contacts ZAR 2 LOW COST, ECONOMY TIMER SMALL SIZES 36 X 36 MM, DIN SIZE DELAY ON MAKE FOUR TIME RANGE FROM 0.05 SEC TO 30 MIN. THREE SUPPLY VOLTAGE POWER-ON GREEN LED HIGH CAPACITY5A D.P. D.T. RELAY TECHNICAL SPECIFICATIONS :
    OCR Scan PDF
    electronic timer
    Electronic timer CT-SAD.22 2CDC 251 100 F0t06 Star-delta change-over with 2 n/o contacts Data sheet � Features  Rated control supply voltage 24‑48 V DC, 24‑240 V AC Single‑function timer star‑delta change‑over
    Original PDF
    Electronic timer CT-TGD.12 2CDC 251 098 F0t06
    Electronic timer CT-TGD.12 2CDC 251 098 F0t06 Pulse generator with 1 c/o contact Data sheet Features �  Rated control supply voltage 24‑48 V DC, 24‑240 V AC Single‑function timer pulse generator 2 x 7 time ranges (0.05 s ‑ 100 h) in one device
    Original PDF
    pulse generator
    Electronic timer CT-TGD.22 2CDC 251 097 F0t06 Pulse generator with 2 c/o contacts Data sheet Features �  Rated control supply voltage 24‑48 V DC, 24‑240 V AC Single‑function timer pulse generator 2 x 7 time ranges (0.05 s ‑ 100 h) in one device
    Original PDF
    Electronic timer CT-AHD.22 2CDC 251 093 F0t06
    Electronic timer CT-AHD.22 2CDC 251 093 F0t06 OFF-delayed with 2 c/o contacts Data sheet Features �  Rated control supply voltage 24‑48 V DC, 24‑240 V AC Single‑function timer OFF‑delay 7 time ranges (0.05 s ‑ 100 h) in one device
    Original PDF
    ct-sdd.22
    Electronic timer CT-SDD.22 2CDC 251 099 F0t06 Star-delta change-over with 2 n/o contacts Data sheet Features �  Rated control supply voltage 24‑48 V DC, 24‑240 V AC Single‑function timer star‑delta change‑over
    Original PDF
    Electronic timer CT-AHD.12 2CDC 251 094 F0t06
    Electronic timer CT-AHD.12 2CDC 251 094 F0t06 OFF-delayed with 1 c/o contact Data sheet Features �  Rated control supply voltage 24‑48 V DC, 24‑240 V AC Single‑function timer OFF‑delay 7 time ranges (0.05 s ‑ 100 h) in one device
    Original PDF
    Electronic timer CT-SDS.22 2CDC 251 083 F0t06
    Electronic timer CT-SDS.22 2CDC 251 083 F0t06 Star-delta change-over with 2 n/o contacts Data sheet Features ᕃ ᕅ ᕆ ᕄ ᕇ ᕈ ½ Rated control supply voltage 24-48 V DC, 24-240 V AC Single-function timer with star-delta change-over
    Original PDF
    Electronic timer CT-ARS.21 OFF-delayed without
    Electronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o contacts Data sheet 2CDC 251 089 F0t07 Features ᕃ ᕅ ᕄ ᕆ  Rated control supply voltage 24‑240 V AC/DC Single‑function OFF‑delay timer without auxiliary voltage
    Original PDF
    Electronic timer CT-SDS.23 2CDC 251 083 F0t06
    Electronic timer CT-SDS.23 2CDC 251 083 F0t06 Star-delta change-over with 2 n/o contacts Data sheet Features ᕃ ᕅ ᕆ ᕄ ᕇ ᕈ ½ Rated control supply voltage 380-440 V AC/DC Single-function timer with star-delta change-over One device includes 7 time ranges (0.05 s - 10 min)
    Original PDF
    Electronic timer CT-ARS.11 OFF-delayed without
    Electronic timer CT-ARS.11 OFF-delayed without auxiliary voltage with 1 c/o contact Data sheet 2CDC 251 088 F0t07 Features ᕃ ᕅ ᕄ ᕆ  Rated control supply voltage 24‑240 V AC/DC Single‑function OFF‑delay timer without auxiliary voltage
    Original PDF
    Electronic timer CT-ERS.21 ON-delayed with 2 c/o
    Electronic timer CT-ERS.21 ON-delayed with 2 c/o contacts Data sheet 2CDC 251 057 F0t07 Features ᕃ ᕅ ᕆ ᕄ ᕇ a  Rotary switch for the preselection of the time range b  Potentiometer with direct reading scale for the fine adjustment of the time
    Original PDF
    Electronic timer CT-ERS.12 ON-delayed with 1 c/o
    Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet 2CDC 251 056 F0t07 Features ᕃ ᕅ ᕆ ᕄ ᕇ  Rated control supply voltage 24‑48 V DC, 24‑240 V AC Single‑function ON‑delay timer One device includes 10 time ranges (0.05 s ‑ 300 h)
    Original PDF
    Electronic timer CT-ERS.22 ON-delayed with 2 c/o
    Electronic timer CT-ERS.22 ON-delayed with 2 c/o contacts Data sheet 2CDC 251 058 F0t07 Features ᕃ ᕅ ᕆ ᕄ ᕇ  Rated control supply voltage 24‑48 V DC, 24‑240 V AC Single‑function ON‑delay timer One device includes 10 time ranges (0.05 s ‑ 300 h)
    Original PDF
    Technical data System pro M Modular Installation
    Technical data System pro M Modular Installation Equipment System pro M SK 6 1 System pro M When connecting aluminium conductors ensure that the contact surfaces of the conductors are cleaned, brushed and treated with grease. Re-tighten contact terminals after 6 to 8 weeks'
    Original PDF