CX1154L
Abstract: CX1154L thyratron CX1154 ka klystron pulse thyratrons Thyratron thyratron tube operation A1A-CX1154L klystron tubes schematic diagram heater
Contextual Info: E2V Technologies CX1154L Deuterium Filled Ceramic Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Deuterium-filled tetrode thyratron with ceramic/metal envelope, featuring fast recovery time, low jitter, firing time
|
Original
|
cx1154lcx1154cx1154l thyratronka klystron pulse+6thyratronsthyratronthyratron tube operationa1a-cx1154lklystron tubesschematic diagram heater
|
PDF
|
CX1154
Abstract: thyratron tube operation thyratron tube thyratron
Contextual Info: E2V Technologies CX1154B Double-Ended Ceramic Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Deuterium-filled, double ended high voltage thyratron with ceramic/metal envelope, featuring low jitter, firing time and
|
Original
|
cx1154bcx1154thyratron tube operationthyratron tube+1thyratron
|
PDF
|
CX1154
Abstract: Thyratron thyratrons thyratron tube operation thyratron diagram
Contextual Info: E2V Technologies CX1154 Deuterium Filled Ceramic Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Deuterium-filled tetrode thyratron with ceramic/metal envelope, featuring low jitter, firing time and drift. Suitable for
|
Original
|
cx1154thyratronthyratronsthyratron tube operation+1thyratron diagram
|
PDF
|
CX1151
Abstract: E2V Technologies tag 725 thyratrons thyratron
Contextual Info: E2V Technologies CX1151 Hydrogen Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Hydrogen-filled tetrode thyratron, featuring low jitter and low anode delay time drift. Suitable for use at high pulse repetition
|
Original
|
cx1151e2v technologiestag 725thyratrons+1thyratron
|
PDF
|
CX1168
Abstract: thyratron
Contextual Info: E2V Technologies CX1168 Two-Gap Deuterium-Filled Ceramic Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Deuterium-filled, two-gap, high voltage thyratron with ceramic/ metal envelope, featuring low jitter, firing time and drift.
|
Original
|
cx11683573bthyratron |
PDF
|
CX1164
Abstract: E2V Technologies thyratron A1A-CX1164 105 Thyratron
Contextual Info: E2V Technologies CX1164 Hydrogen-Filled Ceramic Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Hydrogen-filled tetrode thyratron with ceramic envelope, featuring low jitter and low anode delay time drift. Suitable for
|
Original
|
cx1164e2v technologiesthyratrona1a-cx1164+1105 thyratron
|
PDF
|
KV 147
Abstract: thyratron tube operation CX1174 thyratron 6890A E2V TECHNOLOGIES BR/BW1617F E2V TECHNOLOGIES BR/BW1617F SERIES thyratron tube schematic diagram heater thyratron diagram
Contextual Info: E2V Technologies CX1174 Deuterium-Filled Ceramic Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Deuterium-filled tetrode thyratron with ceramic/metal envelope, featuring low jitter, firing time and drift. Suitable for
|
Original
|
cx1174kv 147thyratron tube operationthyratron+66890ae2v technologies br/bw1617fe2v technologies br/bw1617f seriesthyratron tubeschematic diagram heaterthyratron diagram
|
PDF
|
CX1135
Abstract: thyratron tube operation thyratron tube thyratron
Contextual Info: E2V Technologies CX1135 Hydrogen-Filled Ceramic Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Hydrogen-filled tetrode thyratron with ceramic/metal envelope, featuring low jitter, firing time and drift. Suitable for switching
|
Original
|
cx1135volt187thyratron tube operationthyratron tube+1thyratron
|
PDF
|
CX1559
Abstract: CX-1559 8417 tube thyratron tube operation thyratrons interlock 1672 marconi tube company Marconi Applied Technologies MARCONI DATASHEET MA360A
Contextual Info: Marconi Applied Technologies CX1559 Deuterium Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Deuterium-filled flange mounted tetrode thyratron featuring low jitter and low anode delay time drift. It is designed for
|
Original
|
cx1559cx-15598417 tubethyratron tube operation+6thyratronsinterlock 1672marconi tube companymarconi applied technologiesmarconi datasheetma360a
|
PDF
|
CX1140
Abstract: Thyratron 5949 5949A Thyratron 5948 CV8563 CX-1140 CX1151 MA179 MA360 thyratrons
Contextual Info: CX1140 Service Type CV8563 Hydrogen Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Hydrogen-filled tetrode thyratron, featuring low jitter and low anode delay time drift. Suitable for use at high pulse repetition
|
Original
|
cx1140cv8563thyratron 59495949a+6thyratron 5948cx-1140cx1151ma179ma360thyratrons
|
PDF
|
CX1551
Abstract: CX1159 CX-1159 CX155 MA179 MA360 MA92 thyratron tube thyratron BS448
Contextual Info: CX1159 Service Type CV9080 Deuterium Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Deuterium-filled tetrode thyratron, featuring low jitter and low anode delay time drift. Suitable for use at high pulse repetition
|
Original
|
cx1159cv9080cx1551cx-1159+7cx155ma179ma360ma92thyratron tubethyratronbs448
|
PDF
|
Thyratron
Abstract: CX1171 thyratron tube operation SPACE HEATER thyratron tube schematic diagram Storage heater schematic diagram crowbar for 12 v dc power supply
Contextual Info: E2V Technologies CX1171 Three-Gap Deuterium-Filled Ceramic Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Deuterium-filled, three-gap, high voltage thyratron with ceramic/metal envelope, featuring low jitter, firing time and
|
Original
|
cx1171thyratronthyratron tube operationspace heater+3thyratron tubeschematic diagram storage heaterschematic diagram crowbar for 12 v dc power supply
|
PDF
|
CX1168B
Abstract: thyratron tube operation thyratron tube thyratron thyratron diagram CX1168
Contextual Info: E2V Technologies CX1168B Two-Gap, Double-Ended Ceramic Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Deuterium-filled, two-gap, double ended high voltage thyratron with ceramic/metal envelope, featuring low jitter, firing time
|
Original
|
cx1168bthyratron tube operationthyratron tubethyratron+2thyratron diagramcx1168
|
PDF
|
thyratron 16 H
Abstract: CX1157 CV6241 E2V Technologies cx1157 thyratron 500KV
Contextual Info: E2V Technologies CX1157 Service Type CV6241 Hydrogen-Filled Ceramic Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. (Absolute values) ABRIDGED DATA Hydrogen-filled tetrode thyratron with ceramic envelope, featuring low jitter and low anode delay time drift. Suitable for
|
Original
|
cx1157cv6241thyratron 16 he2v technologies cx1157+2thyratron500kv
|
PDF
|
|
|
thyratron
Abstract: thyratrons thyratron tube operation CX1599 thyratron tube Thyratron recovery time
Contextual Info: CX1599 Hydrogen-Filled Ceramic Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Hydrogen-filled tetrode thyratron with ceramic envelope, featuring extremely low jitter, low anode delay time drift and high rate of rise of current. A hydrogen reservoir operating
|
Original
|
cx1599thyratronthyratronsthyratron tube operation+2thyratron tubethyratron recovery time
|
PDF
|
thyratron tube operation
Abstract: thyratron tube thyratron thyratrons
Contextual Info: FX11A Hydrogen-Filled Ceramic Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Hydrogen-filled triode thyratron with ceramic envelope, featuring low jitter, low anode delay time drift and high rate of rise of current. A hydrogen reservoir operating from a separate
|
Original
|
fx11athyratron tube operationthyratron tubethyratron+1thyratrons
|
PDF
|
CX1159
Abstract: CX-1159 Thyratron 1159 thyratron tube Thyratron recovery time
Contextual Info: CX-1159 NATIONAL DUETERIUM THYRATRON Tetrode ABRIDGED DATA Deuterium Filled Tetrode Thyratron, featuring low jitter and low anode delay time drift. Suitable for use at high pulse repetition rates, in parallel for switching higher powers, or for switching long pulses. A reservoir operating
|
Original
|
cx-115914xl09cx1159thyratron+31159thyratron tubethyratron recovery time
|
PDF
|
thyratron
Abstract: Ignition Transformer H25002 4022D 4078GA
Contextual Info: Ref.: 3V/531 E Hot-Cathode MercuryVapour Thyratron Code: 3V/531E This thyratron is equivalent to, and replaces, the 4078G A type, which is now obsolete. CATHODE. Oxide-coated, shielded filament Filament voltage 5 Nom inal current 20 M inim um cathode heating time ambient
|
OCR Scan
|
v/531v/531e4078ga4022d+623-bo0-37s36-oothyratronignition transformerh25002
|
PDF
|
thyratron tube
Abstract: thyratron
Contextual Info: 627 THYRATRON MERCURY-VAPOR TRIO D E DATA Electrical: Filament: Voltage*. 2.5 Current. 6.0 Direct Interelectrode Capacitance: Anode to Grid Approx. 2.5 Peak Voltage Drop. . . . 12 Control Characteristic . Negative Ionization Time (Approx.)
|
OCR Scan
|
30-second92cs-67392cs-6738ce-6739-p738+2thyratron tubethyratron
|
PDF
|
mercury vapor ignitor
Abstract: thyratron tube thyratron
Contextual Info: 5560 THYRATRON MERCURY-VAPOR TETRODE D A TA El ectr ic a l : Heater, fo r Unipotential Cathode: Voltage. 5 .5 ° 5.0 . Current. 5 .0 ° 4.5 . Cathode: Minimum Heating Time, p rior to tube conduction . . .
|
OCR Scan
|
crid-n8292cm-76s6t7570tce-7556t-7570t+3mercury vapor ignitorthyratron tubethyratron
|
PDF
|
Thyratron
Contextual Info: EN3I GAS FILLED TRIO DE Thyratron for use in H. F. time bases and control equipment. HEATER Vh Ih 6 -3 1 .3 V A 6 -1 4 .2 2 .3 < 1 .5 [ijiT i(iï (i(ii 1 ,5 0 0 1000 10 750 750 0 .7 5 100 33 35 7 V mA mA fi/V m 7 V CAPACITAHCES e in cout C a-g cg-h OPERATING COBDITIOBS A3 TBIOEB
|
OCR Scan
|
250vfthyratron |
PDF
|
Thyratron
Abstract: EN31 MULLARD EN31 EN-31 mullard
Contextual Info: EN3I G A S -FILLE D T R IO D E Thyratron for use in h.f. time bases and control equipment. H EATER V„ Ih C A P A C IT A N C E S Cln Cout ca_« c* h O P E R A T IN G C O N D I T IO N S AS va-g pk max. va (pki max. Ia max. ¡a (pk) max. Rg_k min. Rg. k max
|
OCR Scan
|
thyratronen31mullard en31en-31+1mullard
|
PDF
|
GRID-N22
Abstract: 3D22 thyratron 3D-22
Contextual Info: 3D22 THYRATRON GAS TETRODE GENERAL DATA E le c t r ic a l: H eater, f o r U n ip o t e n t ia l Cathode: Min. Av. V o lt a g e AC o r D C . 5 .7 6 .3 C u rre n t, wi th h e a te r v ol t s = 6 .3 2 .3 5 2 .6 0 Cathode: H e a tin g Time, p r i o r to
|
OCR Scan
|
100ypegrid-n2292cm-6830t92cm-6865t+4ce-6830t-6865t3d22thyratron3d-22
|
PDF
|
|
Contextual Info: HY-3002/5948A-Replacement Hydrogen Filled Triode Thyratron NOTE The HY3002/5948A-REPLACEMENT The HY-3002 is a hydrogen-illed, triode thyratron. The hydrogen gas ill facilitates reliable operation is a HY3002 that incorporates a base at a moderately-high voltage and very high pulse repetition rates when compared to similar
|
Original
|
hy-3002/5948a-replacementhy3002/5948a-replacementhy-3002hy3002+2hy3002/5948areplacementhy-3002/5984a-replacement
|
PDF
|