Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    THERMOCOUPLE TO DIGITAL INTERFACE Search Results

    THERMOCOUPLE TO DIGITAL INTERFACE Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    8251A/BXA
    Rochester Electronics LLC 8251 - Programmable Communication Interface, NMOS, CDIP28 PDF Buy
    MC68B21CP-G
    Rochester Electronics LLC MC68B21 - Peripheral Interface Adapter PDF Buy
    AM7969-125DC
    Rochester Electronics LLC AM7969 - TAXIchip (Transparent Asynchronous Xmitter-Reciever Interface), Receive Interface PDF Buy
    AM7968-175DC
    Rochester Electronics LLC AM7968 - TAXIchip (Transparent Asynchronous Xmitter-Reciever Interface), Transmit Interface PDF Buy
    TLC32044EFN
    Rochester Electronics LLC TLC32044 - Voice-Band Analog Interface Circuits PDF Buy

    THERMOCOUPLE TO DIGITAL INTERFACE Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    Contextual Info: EVALUATION KIT AVAILABLE MAX31850/MAX31851 Cold-Junction Compensated, 1-Wire Thermocouple-to-Digital Converters General Description The MAX31850/MAX31851 cold-junction compensated, 1-WireM thermocouple-to-digital converters perform cold-junction compensation and digitize the signal from


    Original
    MAX31850/MAX31851 MAX31850/MAX31851 1768NC -270NC, -200NC 700NC. PDF

    Contextual Info: EVALUATION KIT AVAILABLE MAX31850/MAX31851 Cold-Junction Compensated, 1-Wire Thermocouple-to-Digital Converters General Description The MAX31850/MAX31851 cold-junction compensated, 1-WireM thermocouple-to-digital converters perform cold-junction compensation and digitize the signal from


    Original
    MAX31850/MAX31851 MAX31850/MAX31851 1768NC -270NC, -200NC 700NC. PDF

    Contextual Info: EVALUATION KIT AVAILABLE MAX31850/MAX31851 Cold-Junction Compensated, 1-Wire Thermocouple-to-Digital Converters General Description The MAX31850/MAX31851 cold-junction compensated, 1-WireM thermocouple-to-digital converters perform cold-junction compensation and digitize the signal from


    Original
    MAX31850/MAX31851 MAX31850/MAX31851 1768NC -270NC, -200NC 700NC. PDF

    Thermocouple Type K linearization

    Abstract: A043 thermocouple to digital interface distributed control system
    Contextual Info: ADTECH Analog-Digital Technology, Inc. Isolated Thermocouple Transmitter Model No. TCT 26 The Adtech Model TCT 26 Isolated Thermocouple Transmitter provides high accuracy conversion of thermocouple signals to a standard process signal such as 4-20 mA DC, 1-5 VDC, or zero-based outputs. It utilizes digital processing with


    Original
    PDF

    NEDA 1604 6F22 006P

    Abstract: FLUKE 36 schematic diagram NEDA 1604 6F22 SAMA-CP45 80PK-2 6F22 9V calibration procedure for thermocouple Fluke Multimeter repair 741512 80PK-1
    Contextual Info: IF L U K E I — — — — Instruction Sheet 80TK Thermocouple Module INTRODUCTION Range Accuracy % of reading + degrees The Fluke 80TK is a thermocouple converter for use with any Ktype thermocouple and a digital multimeter (DMM). The 80TK accepts the output of any K-type thermocouple and converts it to


    OCR Scan
    PDF

    Contextual Info: LE AVAILAB MAX31855 Cold-Junction Compensated Thermocouple-to-Digital Converter General Description The MAX31855 performs cold-junction compensation and digitizes the signal from a K-, J-, N-, T-, S-, R-, or E-type thermocouple. The data is output in a signed


    Original
    MAX31855 MAX31855 14-bit, 1800NC -270NC, -200NC 700NC PDF

    MAX31855

    Abstract: MAX31785 DS1631A MAX6575 SOT23-6 FOOTPRINT MAX663 MAX6652 maxim temp sensors analog design guide Temp sensor DS18B20 MAXIM Pin Compatible Upgrade for
    Contextual Info: Thermal Management Product Guide What’s inside? Page Thermocouple-to-Digital Converter . . . . . . . . . . . . . . 2 Fan Controllers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 High-Accuracy Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . 7


    Original
    LM75-Compatible MAX6501 MAX6505 MAX6509/10 MAX6513 MAX6514/15 MAX6516 MAX6685/86 MAX6687 DS600 MAX31855 MAX31785 DS1631A MAX6575 SOT23-6 FOOTPRINT MAX663 MAX6652 maxim temp sensors analog design guide Temp sensor DS18B20 MAXIM Pin Compatible Upgrade for PDF

    Contextual Info: LE AVAILAB MAX31855 Cold-Junction Compensated Thermocouple-to-Digital Converter General Description The MAX31855 performs cold-junction compensation and digitizes the signal from a K-, J-, N-, T-, S-, R-, or E-type thermocouple. The data is output in a signed


    Original
    MAX31855 MAX31855 14-bit, 1800NC -270NC, -200NC 700NC PDF

    max31855k

    Abstract: MAX31855J MAX31855T max31855 k type thermocouple sensor 10000 MAX31855R max31855kasa cold junction compensation of t type thermocouple MAX31855S 200nC
    Contextual Info: 19-5793; Rev 2; 2/12 MAX31855 Cold-Junction Compensated Thermocouple-to-Digital Converter General Description The MAX31855 performs cold-junction compensation and digitizes the signal from a K-, J-, N-, T-, S-, R-, or E-type thermocouple. The data is output in a signed


    Original
    MAX31855 MAX31855 14-bit, 1800NC -270NC, -200NC 700NC S14-Bit, max31855k MAX31855J MAX31855T k type thermocouple sensor 10000 MAX31855R max31855kasa cold junction compensation of t type thermocouple MAX31855S 200nC PDF

    MAX31855

    Abstract: MAX31855T MAX-31855K MAX31855E
    Contextual Info: 19-5793; Rev 1; 11/11 MAX31855 Cold-Junction Compensated Thermocouple-to-Digital Converter General Description The MAX31855 performs cold-junction compensation and digitizes the signal from a K-, J-, N-, T-, S-, R-, or E-type thermocouple. The data is output in a signed


    Original
    MAX31855 14-bit, 1800NC -270NC, -200NC 700NC MAX31855T MAX-31855K MAX31855E PDF

    Contextual Info: 19-5793; Rev 2; 2/12 MAX31855 Cold-Junction Compensated Thermocouple-to-Digital Converter General Description The MAX31855 performs cold-junction compensation and digitizes the signal from a K-, J-, N-, T-, S-, R-, or E-type thermocouple. The data is output in a signed


    Original
    MAX31855 MAX31855 14-bit, 1800NC -270NC, -200NC 700NC PDF

    adjustable zero span circuit

    Abstract: thermocouple to digital interface dead
    Contextual Info: Thermocouple Alarms ADTECH Analog-Digital Technology, Inc. The Adtech TCA series alarms accept standard ISA thermocouple input signals and provide relay contact outputs. Model No. TCA 104 Single, TCA 105 Dual The basic input range is 0-1 mVDC to 0-80 mVDC input spans and output


    Original
    PDF

    max6675 spi

    Abstract: MAX6675 TC-PVC-K-24-180 Omega k type thermocouple connector kit PCC-SMP MAX6674ISA MAX667 MAX6675ISA EMK107BJ104KA EMK316BJ225ML
    Contextual Info: 19-2345; Rev 1; 02/07 MAX6675 Evaluation Kit The MAX6675 evaluation kit EV kit is an assembled and tested printed circuit board (PCB) that demonstrates the MAX6675 thermocouple digital temperature sensor. It accepts the input from a type-K thermocouple and converts the temperature to 12-bit data.


    Original
    MAX6675 12-bit MAX6675. 95/98/2000/XP MAX6674, MAX6674ISA. max6675 spi TC-PVC-K-24-180 Omega k type thermocouple connector kit PCC-SMP MAX6674ISA MAX667 MAX6675ISA EMK107BJ104KA EMK316BJ225ML PDF

    MAX31855

    Abstract: thermocouple MAX31855K
    Contextual Info: MAX31855 Cold-Junction Compensated Thermocouple-to-Digital Converter General Description The MAX31855 performs cold-junction compensation and digitizes the signal from a K-, J-, N-, T-, S-, R-, or E-type thermocouple. The data is output in a signed 14-bit, SPI-compatible, read-only format. This converter


    Original
    MAX31855 MAX31855 14-bit, thermocouple MAX31855K PDF

    max6674isa

    Contextual Info: 19-2241; Rev 0; 11/01 Cold-Junction-Compensated K-Thermocoupleto-Digital Converter 0°C to +128°C Features ♦ Cold-Junction Compensation The MAX6674 cold-junction-compensation thermocouple-to-digital converter performs cold-junction compensation and digitizes the signal from a type-K


    Original
    MAX6674 10-bit MAX6674 max6674isa PDF

    Contextual Info: 19-2241; Rev 0; 11/01 Cold-Junction-Compensated K-Thermocoupleto-Digital Converter 0°C to +128°C Features ♦ Cold-Junction Compensation The MAX6674 cold-junction-compensation thermocouple-to-digital converter performs cold-junction compensation and digitizes the signal from a type-K


    Original
    MAX6674 10-bit MAX6674 PDF

    MAX31855J

    Abstract: MAX31855 max31855k 200nC Thermocouple Type K MAX31855T
    Contextual Info: 19-5793; Rev 0; 3/11 MAX31855 Cold-Junction Compensated Thermocouple-to-Digital Converter General Description The MAX31855 performs cold-junction compensation and digitizes the signal from a K, J, N, T, or E type thermocouple. Contact the factory for S and R type thermocouples. The data is output in a signed 14-bit, SPI compatible, read-only format. This converter resolves


    Original
    MAX31855 14-bit, 1800NC -270NC, -200NC 700NC MAX31855J max31855k 200nC Thermocouple Type K MAX31855T PDF

    DIODE S5

    Abstract: max6675 spi
    Contextual Info: 19-2235; Rev 0; 10/01 Cold-Junction-Compensated K-Thermocoupleto-Digital Converter 0°C to +1024°C Features ♦ Cold-Junction Compensation ♦ Simple SPI-Compatible Serial Interface ♦ 12-Bit, 0.25°C Resolution ♦ Open Thermocouple Detection Ordering Information


    Original
    MAX6675 12-bit 12-Bit, MAX6675 MAX6675ISA DIODE S5 max6675 spi PDF

    RJ12 to RS485

    Contextual Info: Analog and Digital Output Patented 250 $ iDRN/iDRX ߜ ANALOG OR DIGITAL OUTPUTS ߜ Models Available for: Thermocouple RTD Process Voltage & Current Strain Frequency/Pulse AC Voltage and Current ߜ Up to 1000 Vdc Isolation ߜ DRN Series Provide 0-10 Vdc, 4-20 mA or


    Original
    RS-485 RS-485 DB9-RJ12 C-12B RJ12 to RS485 PDF

    4-20mA to SPI Converter

    Abstract: c code for interpolation and decimation filter APP1870 how does a resistance to Current Converter 4-20mA 4-20ma ADC INPUT 4-20ma interface WITH ADC circuit diagram temperature measurement rtd MAX1400 MAX1402 Seebeck generator
    Contextual Info: Maxim > App Notes > A/D and D/A CONVERSION/SAMPLING CIRCUITS TEMPERATURE SENSORS and THERMAL MANAGEMENT Keywords: Delta-Sigma, analog to digital converters, ADCs, A to D, A/D, oversampling, noise shaping, decimation, decimation filters, MAX1402, thermocouple measurement, RTD, resistance temperature detectors,


    Original
    MAX1402, 4-20mA, 4-20mA com/an1870 MAX1400: MAX1402: AN1870, APP1870, Appnote1870, 4-20mA to SPI Converter c code for interpolation and decimation filter APP1870 how does a resistance to Current Converter 4-20mA 4-20ma ADC INPUT 4-20ma interface WITH ADC circuit diagram temperature measurement rtd MAX1400 MAX1402 Seebeck generator PDF

    Contextual Info: DRP-8500 Series Low Cost Analog to Frequency Modules for Micro PLC Digital Inputs From 105 $ ߜ DRP-8500 Series Connect to Micro PLCs High Speed Counter Inputs ߜ DRP-8600 Series Connect to Micro PLCs 24 VDC Logic Inputs ߜ Voltage, Current, RTD, Thermocouple and


    Original
    DRP-8500 DRP-8600 volta00 DRP-8555 DRP-8605 DRP-8606 DRP-8607 DRP-8611 PDF

    G4AD8

    Abstract: G4 thermocouple opto 501 G4AD17 G4AD23
    Contextual Info: I/O MODULES G4 ANALOG INPUT DATA SHEET page 1/3 Form 422-050809 Description Thermocouple analog modules provide a single channel of transformer and optically- isolated temperature-to-digital conversion. The modules offer wide nominal input range and special over/under range capabilities. The modules also include


    Original
    321-OPTO opto22 43044Sales: G4AD8 G4 thermocouple opto 501 G4AD17 G4AD23 PDF

    DIODE S5

    Abstract: MAX6675 circuit with thermocouple application 68HC11A8 MAX6675ISA thermocouple to frequency
    Contextual Info: 19-2235; Rev 1; 3/02 Cold-Junction-Compensated K-Thermocoupleto-Digital Converter 0°C to +1024°C Features The MAX6675 performs cold-junction compensation and digitizes the signal from a type-K thermocouple. The data is output in a 12-bit resolution, SPI -compatible, read-only format.


    Original
    MAX6675 12-bit 12-Bit, MAX6675 DIODE S5 circuit with thermocouple application 68HC11A8 MAX6675ISA thermocouple to frequency PDF

    Contextual Info: MAX6675 LE AVAILAB Cold-Junction-Compensated K-Thermocoupleto-Digital Converter 0°C to +1024°C General Description Features The MAX6675 performs cold-junction compensation and digitizes the signal from a type-K thermocouple. The data is output in a 12-bit resolution, SPI -compatible, read-only format.


    Original
    MAX6675 MAX6675 12-bit 12-Bit, PDF