Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    TESYS SCHEMES Search Results

    Documents mentioning TESYS SCHEMES

    Document Partial File Text Tags Type PDF
    TeSys protection components Presentation,
    TeSys protection components Presentation, description 3-pole thermal overload relays TeSys D Presentation TeSys D thermal overload relays are designed to protect a.c. circuits and motors against: b overloads, b phase failure, b excessively long starting times,
    Original PDF
    soft starters
    Schemes 1 Soft starters for asynchronous motors Altistart U01 and TeSys model U For 0.75 to 15 kW motors ATSU 01N2ppLT soft start/soft stop units 5/L3 3/L2 1/L1 5/L3 Power wiring with reversing unit 3/L2 1/L1 Power wiring – QF1 – QF1 TeSys model U CU TeSys
    Original PDF
    TeSys contactors References 526172 TeSys D,
    TeSys contactors References 526172 TeSys D, 3-pole reversing contactors for motor control up to 75 kW at 400 V, in category AC-3 Horizontally mounted, pre-assembled 3-pole reversing contactors for connection by screw clamp terminals Pre-wired power connections.
    Original PDF
    altistart
    Presentation 1 Soft starters for asynchronous motors 1 Altistart U01 and TeSys model U Presentation The Altistart U01 is a soft start/soft stop unit for asynchronous motors. It is designed primarily for combinations with TeSys model U controller-starters.
    Original PDF
    tesys d contactors
    TeSys contactors Characteristics TeSys D contactors Contactor type LC1 D09…D18 DT20 and DT25 D25…D38 DT32 and DT40 D40A…D65A DT60A and DT80A D80…D95 D115 and D150 Environment Rated insulation voltage (Ui) Rated impulse withstand voltage (Uimp) Conforming to IEC 60947-4-1,
    Original PDF
    TeSys contactors References TeSys D contactors for motor control up to 75 kW at 400 V, in category AC-3 810356 For connection by screw clamp terminals and lugs 3-pole contactors Standard power ratings of 3-phase motors 50-60 Hz in category AC-3 (θ y 60 °C)
    Original PDF
    TeSys Model U Selection guide Starter-controllers
    TeSys Model U Selection guide Starter-controllers Function performed Function not performed Selectable overload class Detection of overtorque, no-load running, long starting times Earth fault protection (equipment protection only) Protection against phase imbalance
    Original PDF
    Selection guide TeSys Model U Starter-controllers
    Selection guide TeSys Model U Starter-controllers Control units Function characteristics Control units Standard LUCA Thermal overload protection Overcurrent protection Advanced LUCB LUCC LUCD 14.2 x the setting current Short-circuit protection Protection against phase loss
    Original PDF
    References TeSys contactors Component parts for
    References TeSys contactors Component parts for assembling reversing contactors for motor control or low speed - high speed starters For 3-pole motor reversing contactors using 2 identical contactors 810373 Contactors with screw clamp terminals or connectors
    Original PDF
    TeSys contactors References 537729 Component
    TeSys contactors References 537729 Component parts for assembling reversing contactors for motor control, low-speed/high-speed starters and star-delta starters For 3-pole reversing contactors for motor control Contactors with screw clamp terminals or connectors. Horizontally mounted, assembled by customer
    Original PDF
    tesys
    24505 Page 62 Thursday, October 25, 2001 5:44 PM Characteristics TeSys contactors Model d Farnell Codes ; 4231855 - 4232148 Type of contactor LC1LC1D09…D18 D25…D38 DT20 & DT25 DT32…DT6 LC1D40 1000 LC1D50…D95 LC1-D115 & LC1-D150 Environment Rated insulation voltage (Ui)
    Original PDF
    lr97
    TeSys protection components Presentation, description Electronic over current relays Presentation 109487 LR97 D and LT47 electronic over current relays have been developed to satisfy machine protection requirements. These relays have definite time characteristics: current threshold and time based function.
    Original PDF
    lc1-d115
    Characteristics TeSys contactors Model d Type of contactor LC1LC1LC1D09…D18 D25…D38 D40 DT20 & DT25 DT32…DT60 LC1D50…D95 LC1-D115 & LC1-D150 Environment Rated insulation voltage (Ui) Rated impulse withstand voltage (Uimp) 2 Conforming to EN 60947-4-1,
    Original PDF
    24516 Page 108 Friday, October 26, 2001 9:32 AM
    24516 Page 108 Friday, October 26, 2001 9:32 AM Description, characteristics TeSys protection components 3-pole thermal overload relays, model d Description Model d 3-pole thermal overload relays are designed to protect a.c. circuits and motors against overloads, phase failure,
    Original PDF
    tesys
    24531 Page 94 Thursday, October 25, 2001 6:02 PM Dimensions TeSys contactors Model d contactors Control circuit: a.c. LC1-D09…D18 (3-pole) LC1-D25…D38 (3-pole) LC1-DT20…DT60 (4-pole) 44 Minimum electrical clearance 44 Minimum electrical clearance LA4
    Original PDF
    References TeSys contactors 5 5 Reversing
    References TeSys contactors 5 5 Reversing contactors for motor control up to 75 kW at 400 V, in category AC-3 Horizontally mounted, pre-assembled Control circuit: a.c., d.c. or low consumption 810369 3-pole reversing contactors for connection by screw clamp terminals or connectors
    Original PDF
    schneider
    Chapter 3: Contents Schneider Electric TeSys motor circuit-breakers Selection guide: Thermal-magnetic motor circuit-breakers pages 3/2 and 3/3 Selection guide: Magnetic motor circuit-breakers pages 3/4 and 3/5 Thermal-magnetic motor circuit-breakers types GV2, GV3 and GV7
    Original PDF
    iec 60439-1
    TeSys enclosed starters Characteristics, references 2 2 D.O.L. starters for motor control (1) 2.2 to 45 kW, with isolating device Characteristics Conforming to standards IEC 60947-4-1 and IEC 60439-1, VDE 0660-102, EN 60947 Ambient air temperature IP 659: LEp K
    Original PDF
    tesys
    Characteristics, references TeSys enclosed starters 2 2 Star-delta starters (1) 7.5 to 75 kW with isolating device Characteristics Conforming to standards IEC 60947-4-1 and IEC 60439-1, VDE 0660-102, EN 60947 Degree of protection conforming to IEC 60529 Ambient air temperature
    Original PDF
    gv2-m
    Curves TeSys protection components Thermal-magnetic motor circuit-breakers types GV2-ME and GV2-P Thermal-magnetic tripping curves for GV2-ME and GV2-P Average operating time at 20 °C according to multiples of the setting current Time (s) 10 000 1000 100
    Original PDF
    References 6 TeSys protection components 6 3-pole
    References 6 TeSys protection components 6 3-pole thermal overload relays, model d 810464 Differential thermal overload relays for use with fuses b Compensated relays with manual or automatic reset, b with relay trip indicator, b for a.c. or d.c. Relay setting range (A)
    Original PDF
    lc1lc1lc1d09
    Characteristics TeSys contactors 5 Model d Type of contactor LC1LC1LC1D09…D18 D25…D38 D40 DT20 & DT25 DT32 & DT40 LC1D50…D95 LC1-D115 & LC1-D150 Environment Rated insulation voltage (Ui) 2 Rated impulse withstand voltage (Uimp) Conforming to IEC EN 947-4-1,
    Original PDF
    References 5 TeSys contactors 5 Contactors for
    References 5 TeSys contactors 5 Contactors for motor control, 6 to 16 A in category AC-3 and 6 to 12 A in category AC-4 Control circuit: a.c. 106151_1 Contactor selection according to utilisation category, see pages 24565/2 to 24565/5 and 24566/2 to 24566/5.
    Original PDF
    gv2-m
    Characteristics TeSys protection components Thermal-magnetic motor circuit-breakers Environment Circuit-breaker type GV2-ME Conforming to standards EN 60947-1, 947-2, 947-4-1, EN 60204, UL 508, CSA C22-2 n° 14, NF C 63-650, 63-120, 79-130, VDE 0113, 0660
    Original PDF
    lc1-d09
    Dimensions TeSys contactors Model d contactors Control circuit: a.c. LC1-D09…D18 (3-pole) LC1-D25…D38 (3-pole) LC1-DT20…DT60 (4-pole) 44 Minimum electrical clearance 44 Minimum electrical clearance LA4 b b b1 b1 LA4 D093… D183 99 107 123 (1) 132 (1)
    Original PDF