Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    TESYS D C Search Results

    TESYS D C Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    DEO2V2P500M40LF
    Amphenol Communications Solutions D-Sub Power Board Mount Connectors, Input Output Connectors, Full Power 2V2 Pin Right Angle Solder 40A, Europe Standard, 200 Cycles, Front: Threaded Insert UNC 4.40, Back: Metal Brackets. PDF
    DE2V2P543G30LF
    Amphenol Communications Solutions D-Sub Power Board Mount Connectors, Input Output Connectors, Full Power 2V2 Pin Right Angle Solder 30A, Europe Standard, 500 Cycles, Front: Without Accessory, Back: Harpoons for 1.6mm PCB Thickness. PDF
    DAL3W3P543M30LF
    Amphenol Communications Solutions D-Sub Power Board Mount Connectors, Input Output Connectors, Full Power 3W3 Pin Right Angle Solder 30A, Europe Standard, 500 Cycles, Front: Threaded Insert M3, Back: Metal Brackets. PDF
    DAV3W3P500A30LF
    Amphenol Communications Solutions D-Sub Power Board Mount Connectors, Input Output Connectors, Full Power 3W3 Pin Right Angle Solder 30A, Europe Standard, 200 Cycles, Front: Female Screw Lock UNC 4.40, Back: Without Accessory on PCB. PDF
    DAO3W3P543A30LF
    Amphenol Communications Solutions D-Sub Power Board Mount Connectors, Input Output Connectors, Full Power 3W3 Pin Right Angle Solder 30A, Europe Standard, 500 Cycles, Front: Threaded Insert UNC 4.40, Back: Without Accessory on PCB. PDF

    Documents mentioning TESYS D C

    Document Partial File Text Tags Type PDF
    cad32
    Product Data Sheet CAD326G7 Control Relay , Type: D-Line List Price $62.00 USD Availability Non-Stock Item: This item is not normally stocked in our distribution facility. Technical Characteristics Marketing Trade Name TeSys Catalog Reference Number 8501CT0101
    Original PDF
    tesys
    TeSys™ D-Line Contactor Accessories Coil Suppressors, Cabling Accessories www.SquareD.com For the most up-to-date information Resistor/capacitor circuit (RC) for reduction of “electrical noise” in AC contactor coils Effective protection of circuits sensitive to high frequency interference.
    Original PDF
    lr97
    TeSys protection components Presentation, description Electronic over current relays Presentation 109487 LR97 D and LT47 electronic over current relays have been developed to satisfy machine protection requirements. These relays have definite time characteristics: current threshold and time based function.
    Original PDF
    tesys contactors
    References TeSys contactors a.c. coils for 3-pole contactors LC1-D Control circuit voltage Uc V Average resistance at 20 °C ± 10 % Ω Inductance of closed circuit H Reference (1) Weight kg For 3-pole " contactors LC1-D09…D38 and LC1-DT20…DT60 Specifications
    Original PDF
    lc1lc1lc1d09
    Characteristics TeSys contactors 5 Model d Type of contactor LC1LC1LC1D09…D18 D25…D38 D40 DT20 & DT25 DT32 & DT40 LC1D50…D95 LC1-D115 & LC1-D150 Environment Rated insulation voltage (Ui) 2 Rated impulse withstand voltage (Uimp) Conforming to IEC EN 947-4-1,
    Original PDF
    References 6 TeSys protection components 6 3-pole
    References 6 TeSys protection components 6 3-pole thermal overload relays, model d 810464 Differential thermal overload relays for use with fuses b Compensated relays with manual or automatic reset, b with relay trip indicator, b for a.c. or d.c. Relay setting range (A)
    Original PDF
    lc1-d09
    Dimensions TeSys contactors Model d contactors Control circuit: a.c. LC1-D09…D18 (3-pole) LC1-D25…D38 (3-pole) LC1-DT20…DT60 (4-pole) 44 Minimum electrical clearance 44 Minimum electrical clearance LA4 b b b1 b1 LA4 D093… D183 99 107 123 (1) 132 (1)
    Original PDF
    TeSys Model U Curves Starter-controllers Tripping
    TeSys Model U Curves Starter-controllers Tripping curves for control units LUCA, LUCB, LUCD Time (s) Average operating times at 20 ˚C according to multiples of the setting current, tolerance : ± 20 %. 1000 1 100 2 3 10 1 0,1 1 2 3 4 5 6 7 8 10 12 14 20 30
    Original PDF
    soft starters
    Schemes 1 Soft starters for asynchronous motors Altistart U01 and TeSys model U For 0.75 to 15 kW motors ATSU 01N2ppLT soft start/soft stop units 5/L3 3/L2 1/L1 5/L3 Power wiring with reversing unit 3/L2 1/L1 Power wiring – QF1 – QF1 TeSys model U CU TeSys
    Original PDF
    gv2-me
    Dimensions, mounting TeSys protection components Thermal-magnetic motor circuit-breakers types GV2-ME and GV2-P GV2-ME GV-AX GV-AD, AM, AN, AU, AS, AX GV-AE 15 = b 45 = 10 X1 Block GV-AD, AM, AN Block GV-AU, AS, AX 46 44,5 11 16 9,3 9,3 X1 15,7 18 81(1) 67,2
    Original PDF
    Soft starters ATS 01 Catalogue May 07 General
    Soft starters ATS 01 Catalogue May 07 General contents Soft starters for asynchronous motors 1 – Altistart 01 2 – Altistart U01 1 Contents 1 - Altistart 01 soft starters for asynchronous motors b Presentation… pages 1/2 and 1/3
    Original PDF
    TeSys Model U Selection guide Starter-controllers
    TeSys Model U Selection guide Starter-controllers Function performed Function not performed Selectable overload class Detection of overtorque, no-load running, long starting times Earth fault protection (equipment protection only) Protection against phase imbalance
    Original PDF
    Selection guide TeSys Model U Starter-controllers
    Selection guide TeSys Model U Starter-controllers Control units Function characteristics Control units Standard LUCA Thermal overload protection Overcurrent protection Advanced LUCB LUCC LUCD 14.2 x the setting current Short-circuit protection Protection against phase loss
    Original PDF
    tesys
    Characteristics TeSys protection components Thermal-magnetic motor circuit-breakers Environment Circuit-breaker type GV2-ME Conforming to standards EN 60947-1, 947-2, 947-4-1, EN 60204, UL 508, CSA C22-2 n° 14, NF C 63-650, 63-120, 79-130, VDE 0113, 0660
    Original PDF
    l
    Motor control Accurate and reliable control of motors Te Sys range provide you more simplicity, compactness, openness and flexibility… so man y evolutions and new items to aid your productivity. Search By Part Number TeSys For a new start! A range of simple,
    Original PDF
    modicon m340
    Presentation Modicon M340 automation platform CANopen machine and installation bus Presentation Schneider Electric has selected CANopen for its machines and installations because of its wealth of functions and its resulting benefits in the automation world. This
    Original PDF
    Issued November 2009 DATA SHEET LR-D OVERLOAD
    Issued November 2009 DATA SHEET LR-D OVERLOAD RELAYS Based on Schneider MKTED205103EN Catalogue 12493 General 6 12493 Protection components 6 Motor protection Operating conditions There are many possible causes of electric motor failure. One of the most common,
    Original PDF
    References TeSys contactors Component parts for
    References TeSys contactors Component parts for assembling reversing contactors for motor control or low speed - high speed starters For 3-pole motor reversing contactors using 2 identical contactors 810373 Contactors with screw clamp terminals or connectors
    Original PDF
    tesys
    Characteristics, references TeSys enclosed starters 2 2 Star-delta starters (1) 7.5 to 75 kW with isolating device Characteristics Conforming to standards IEC 60947-4-1 and IEC 60439-1, VDE 0660-102, EN 60947 Degree of protection conforming to IEC 60529 Ambient air temperature
    Original PDF
    iec 60439-1
    TeSys enclosed starters Characteristics, references 2 2 D.O.L. starters for motor control (1) 2.2 to 45 kW, with isolating device Characteristics Conforming to standards IEC 60947-4-1 and IEC 60439-1, VDE 0660-102, EN 60947 Ambient air temperature IP 659: LEp K
    Original PDF
    s0556-en
    1 2 3 4 5 6 7 8 9 10 5/0 version: 1.0 S0556-EN_Ver1.0.indd Content chapter 5 Safety control and protection solutions Mini-VARIO and VARIO switch disconnectors Selection guide: Mini-VARIO and VARIO switch disconnectors… 5/2 1 Mini-VARIO switch disconnectors
    Original PDF
    Model 6 Motor Control Centers Catalog
    Model 6 Motor Control Centers Catalog 8998CT9701R07/09 2009 Class 8998 CONTENTS Description… Page Product Description… 7
    Original PDF
    Automation solution for simple machines Startup
    Automation solution for simple machines Startup Guide 05/2005 DIA3CD3050101F DIA3CD3050101F eng 2 Table of Contents Safety Information… 7 Part I Presentation of the automation solution for simple
    Original PDF
    Table of Contents Section 23 Relays and Timers
    Table of Contents Section 23 Relays and Timers General Purpose Relays New! RXM, p. 23-6 RSL, p. 23-45 Zelio® Plug-in Relays Square D® Plug-in Square D® Alternating Plug-in Square D® Miniature Plug-in Square D® Sockets Square D® Power 23-2 23-9 23-10
    Original PDF
    global specialist in energy management The
    global specialist in energy management The architects of efficiency Singapore Mongolia Price List Catalogue 2013 Electrical Distribution, Automation & Control  ! % 3% %3 (    3'33, )3 3% %3 (  +3&-==33&2/=
    Original PDF