| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| CO-316SMAX200-001 | Amphenol Cables on Demand | Amphenol CO-316SMAX200-001 RG316 High Temperature Teflon Coaxial Cable - SMA Male to SMA Male 1ft | |||
| CO-316SMAX200-003 | Amphenol Cables on Demand | Amphenol CO-316SMAX200-003 RG316 High Temperature Teflon Coaxial Cable - SMA Male to SMA Male 3ft | |||
| CO-316SMAX200-004 | Amphenol Cables on Demand | Amphenol CO-316SMAX200-004 RG316 High Temperature Teflon Coaxial Cable - SMA Male to SMA Male 4ft | |||
| CO-316SMAX200-010 | Amphenol Cables on Demand | Amphenol CO-316SMAX200-010 RG316 High Temperature Teflon Coaxial Cable - SMA Male to SMA Male 10ft | |||
| CO-316SMAX200-005 | Amphenol Cables on Demand | Amphenol CO-316SMAX200-005 RG316 High Temperature Teflon Coaxial Cable - SMA Male to SMA Male 5ft |
Documents mentioning TEMPERATURE SENSOR PT1
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| humidity sensor | AB-5959 Specifications/Instructions Neosensor / Neomini Sensor Room Temperature / Humidity Sensor HTY70X3 / TY70X3 / HY70X3 General Room temperature/humidity sensor HTY70X3 series uses a Pt100 platinum film temperature sensing element and a polymer capacitive film humidity sensing element (FP3 |
Original | ||||
| duct temperature sensor | 1 Duct temperature sensor 778 FK-TP/200 for HVAC systems Duct temperature sensor for heating, ventilation and air conditioning systems – For use with controllers with Pt100 sensor inputs – In conjunction with MULTIREG and INTEGRAL RS. Use The FK-TP/200 duct temperature sensor can be used in air ducts for heating, ventilation |
Original | ||||
| 5013a | AB-5013A Specifications/Instructions Comfort Sensor TY4700A General The Comfort Sensor detects the perceived temperature consisting of air temperature, mean radiant temperature, air velocity, which the processor unit converts into the sensor signal. This sensor can be used with Yamatake’s Direct Digital |
Original | ||||
| hty79x3 | AB-5963 Specifications/Instructions Insertion Dewpoint Temperature Sensor HTY79X3 / HY79X3 General Insertion dewpoint temperature sensor HTY79X3 series uses a Pt100 platinum film temperature sensing element and a polymer capacitive film humidity sensing element |
Original | ||||
| humidity sensor | AB-5961 Specifications/Instructions Insertion Temperature/Humidity Sensor HTY78X3/ TY78X3/ HY78X3 General Insertion temperature/humidity sensor HTY78X3 series uses a Pt100 platinum film temperature sensing element and a polymer capacitive film humidity sensing element |
Original | ||||
| temperature sensor | 1 797 FT-TP/100 FT-TP/400 Immersion temperature sensor for HVAC systems Immersion temperature sensor for heating, ventilation and air conditioning systems • For use with controllers with Pt100 sensor inputs • In conjunction with MULTIREG and INTEGRAL RS. |
Original | ||||
| ss2-att110-0100 | No. SS2-ATT110-0100 ThermoPLUS Smart Temperature Transmitter Model ATT61/71 (Integral Sensor type) OVERVIEW The models ATT61/71 Smart Transmitter are temperature transmitters for the model ATT90 integral temperature sensor and models ATT9F protecting wells for the temperature sensor. It converts and transmits the input signal |
Original | ||||
| irpt100 | IRPT100Ex Ex Temperature sensor PT100 Temperature sensor for hazardous areas • Small construction • Latest Standards • MI-Cable • 4 wire • Up to 550 °C • Features The IRPT100EX is a 1.000mm long PT100 with a diameter of 3 mm. The sensor is for measuring |
Original | ||||
| humidity sensor | Humidity Sensor Temperature/Humidity Sensor ES2-HB ES2-THB Detect Humidity within an Accuracy of ±3% in a Compact Body. Controller Set Provides Superior Humidity Control and Temperature/ Humidity Control. • Employs high-polymer-resistive Sensor with superior durability. |
Original | ||||
| R300 Series Temperature Sensor DESCRIPTION Other | R300 Series Temperature Sensor DESCRIPTION Other potential applications for this harsh duty sensor may The R300 Series is a passive, resistive temperature device include fluid or air temperature sensing within the engine (RTD), high temperature probe. This product features a robust, |
Original | ||||
| thermistor | TEMPERATURE SENSOR The TEMPERATURE SENSOR is assembled one with various parts and thermistor devices according to the required applications. lts electric characteristics are the same as those of thermistor devices. Variable type of sensor can be utilized for detecting or controlling |
Original | ||||
| thermistor | TEMPERATURE SENSOR The TEMPERATURE SENSOR is assembled one with various parts and thermistor devices according to the required applications. lts electric characteristics are the same as those of thermistor devices. Variable type of sensor can be utilized for detecting or controlling |
Original | ||||
| humidity sensor | Humidity Sensor Temperature/Humidity Sensor ES2-HB ES2-THB CSM_ES2-HB_ES2-THB_DS_E_2_1 Detect Humidity within an Accuracy of ±3% in a Compact Body. Controller Set Provides Superior Humidity Control and Temperature/ Humidity Control. • Employs high-polymer-resistive Sensor with superior durability. |
Original | ||||
| ss2-att900-0100 | No. SS2-ATT900-0100 ThermoPLUS Temperature Sensor Model ATT90 OVERVIEW The model ATT90 temperature sensor , which is designed to be used in conjunction with the Smart Temperature Transmitter model ATT61/71, is comprised of various sheathed thermocouple and a sheathed resistance temperature detector (RTD) combinations. |
Original | ||||
|
|
||||||
| Platinum - 600°C Platinum Thin-Film Temperature | Platinum - 600°C Platinum Thin-Film Temperature Sensor 2,3x2mm Product The combination of knowledge in the field of sensor technology and perfectly matched materials are key to this precise platinum thin-film temperature sensor. It shows an excellent long-term stability and resistance to thermal |
Original | ||||
| 2.0 Push Button PT100 Tx Temperature Transmitter | 2.0 Push Button PT100 Tx Temperature Transmitter RECEIVING AND UNPACKING 3.0 SPECIFICATION @ 20 °C INPUT Sensor Type Sensor Range Sensor Connection Minimum span (see note 1) Linearisation Accuracy (see note 2) Thermal Drift Excitation current Lead Resistance effect |
Original | ||||
| mcr-sl-pt100 | Temperature Measuring Transducer for PT100 MCR-SL-PT100-…-DC-24 1. Description MCR-SL-PT100 temperature measuring transducers convert the measured values of the PT100 sensor (IEC rigid751/EN 60751) into electrically standardized analog signals. The sensor is supplied from the module with a low |
Original | ||||
| ab-5429 | AB-5429 Specifications/Instructions Pipe Insertion Sensor TY783 General The pipe insertion temperature sensor (TY783) has the output characteristics of a Pt100 platinum resistance (JIS C1604A) and is used for temperature reading, control and recording of a variety of liquids inside pipes, tanks or heat |
Original | ||||
| ntc sensor | Datenblatt / Data sheet Temperatursensor/ Temperature Sensor 94 121 NTC Sensor / PT-1000 Sensor Flüssige Medien – z.B. Wasser, Öl, Kraftstoff liquid media e.g. water, oil, fuel Medien media Nennwiderstand NTC Alternativ Nennwiderstand PTC Temperaturbereich |
Original | ||||
| pt 1000 sensor | Du line Temperature Sensor Type G 8611 1010 ® Fieldbus Installationbus • AnaLink temperature transmitter with built-in Pt 1000 sensor • Temperature range: -30°C to +60°C (-22° to +140°F) • Uses only 1 channel • Channel coding by GAP 1605 • Easily mountable |