Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    TAB FASTON SC Search Results

    TAB FASTON SC Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    5159002311193111LF
    Amphenol Communications Solutions Standard Power Receptacle, Type F24/H7, Vertical, Solder-to-Wire/Faston, 31 Position, 5.08mm (0.2inch) Centerline PDF
    51590291519620LF
    Amphenol Communications Solutions Standard Power Receptacle, Type H, Vertical, Faston, 15 Position, 10.16mm (0.4 in) Centerline PDF
    5159002311194111LF
    Amphenol Communications Solutions Standard Power Receptacle, Type F24/H7, Vertical, Solder-to-Wire/Faston, 31 Position, 5.08mm (0.2inch) Centerline PDF
    U77A22182001
    Amphenol Communications Solutions ENHCD EMI TABS PDF
    UE78B412700621
    Amphenol Communications Solutions 2X4 SFP COMBO GND TABS PDF

    Documents mentioning TAB FASTON SC

    Document Partial File Text Tags Type PDF
    108-1285 Product Specification 25Jul11 Rev D
    108-1285 Product Specification 25Jul11 Rev D Ultra-Pod Fully Insulated FASTON* Receptacle and Tab 1. SCOPE 1.1. Content This specification covers the perform ance, tests and quality requirem ents for Ultra-Pod fully insulated FASTON* receptacles and tabs. These connectors consist of a FASTON receptacle (tab) body that is
    Original PDF
    114-20119 Application Specification Rev. A1
    114-20119 Application Specification Rev. A1 FASTIN-FASTON* Connectors, 6.3 mm srs. TAB CONTACTS 1. SCOPE This specification covers the requirements for application of 6.3 mm series FASTIN-FASTON* Tab contacts. These requirements are applicable to automatic machine crimping tools.
    Original PDF
    1-293041-1
    Packaging Specification 107-20251 FOR FASTIN-FASTON* Connector, 6.3 mm series, TAB CONTACT Rev. A1 1. SCOPE This specification covers the material and standard method of packaging for Strip Form terminals, FASTIN-FASTON* Connector, 6.3 mm series TAB CONTACT, P/N.s 293041-1, 293041-2, 1-293041-1, 1-293041-2, 293121-1, 293121-2,
    Original PDF
    vite
    Varianti - Alternatives - Autres versions - Ändern *-4 l i ^ FV 110 B Morsettiera vite/faston a 3 poli con polo di terra. Screw to triple tab terminal block 3pole.With integral earth-bracket. Bornier vis/faston à 3 pôles avec patte de terre. Klemmkasten Schraube/Faston 3 Pole mit
    OCR Scan PDF
    AMP AMP FASTON-Steckverbinder AMP FASTON
    AMP AMP FASTON-Steckverbinder AMP FASTON Connectors LIF FASTONSteckhülsen Größe .250 (6,3 mm) LIF FASTON Receptacles Size .250 (6.3 mm) Für Flachstecker 6,3 mm X 0,8 mm For Tab 6.3 mm X 0.8 mm B Typ Type Bestell-Nummern/Part Numbers Abmessungen Dimensions
    OCR Scan PDF
    i USED ON DOUBLE TAB FLAT * U1 SIN G L E TAB TY
    i USED ON DOUBLE TAB FLAT * U1 SIN G L E TAB TY PE FLAT o DO NOT SCALE DRAWING SERIES 601718 AND 601719 COME COMPLETE WITH ONE DOUBLE FLAT AND ONE DOUBLE 45°FAST0N TAB AT EACH POSITION. FLAT D O UBLE 45° TAB 90° FASTON TABS .1 8 7 .2 5 0 P A R T NO. P A R T NO.
    OCR Scan PDF
    114-20021 Application Specification Rev. D12
    114-20021 Application Specification Rev. D12 FASTIN-FASTON* Connectors, .110”, .250”, .312” & .375” srs. TAB & RECEPTACLE CONTACTS 1. SCOPE This specification covers the requirements for application of .110”, .250”, .312” and .375” series FASTINFASTON* Tab & Receptacle contacts. These requirements are applicable to automatic machine crimping
    Original PDF
    FASTON* 110, 187, 205, 250, and 312 Series Tab
    FASTON* 110, 187, 205, 250, and 312 Series Tab Contacts for Printed Circuit (PC) Board Applications NOTE i Application Specification 114-- 2115 24 SEP 09 Rev D All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and
    Original PDF
    501-20122 Qualification Test Report Rev. B1 2-12
    501-20122 Qualification Test Report Rev. B1 2-12 Position, FASTIN-FASTON* TAB Housing, RAST 5 1. INTRODUCTION Purpose This document summarizes testing activity performed on the subject TE Product and establishes its resistance to heat and fire. Scope This report covers the performance to the Glow wire test of the subject product as per IEC 60695-2-11
    Original PDF
    Application Specification 114-2070 AMPLIVAR*
    Application Specification 114-2070 AMPLIVAR* FASTON* Tab Contacts NOTE i 08 DEC 08 Rev A All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2 .
    Original PDF
    114-2078
    Application Specification 114-2078 FASTON* Flag Receptacles with Tab-Lok Feature NOTE i 06 AUG 08 Rev M All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2 .
    Original PDF
    Application Specification 114-2146 AMPLIVAR*
    Application Specification 114-2146 AMPLIVAR* FASTIN-FASTON* Series 187 and 250 Tab Contacts NOTE i 12 JUN 07 Rev C All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2 .
    Original PDF
    TYCO ELECTRONICS TECHNOLOGY PORTFOLIO Connector
    TYCO ELECTRONICS TECHNOLOGY PORTFOLIO Connector Systems / Electromechanical Components Circuit Protection Devices Magnetics Wireless Components Racks and Panels Antennas, GPS Antennas, Integrated Antenna Systems Touch Screens Resistors and Inductors Printed Circuit Board
    Original PDF
    114-20023
    Application Specification 114-20023 Rev.G8 FASTON* Connector,.250” sr. Receptacle Contact (Standard and Piggy-Back versions) & LIF Receptacle contact. 1. SCOPE This specification covers the requirements for application of .250” sr. FASTON* Receptacle contacts (Standard and
    Original PDF
    Interconnection Systems Selection Guide 82750
    Interconnection Systems Selection Guide 82750 Revised 7:95 FASTON Terminals (Insulated and Uninsulated) Insulating Sleeves fo r Flag FASTON Receptacles Receptacles and Tabs Terminals and Splices Product Facts ■ FASTON Terminal Products meet or exceed Industry Standards.
    OCR Scan PDF
    FASTON Terminals Insulated and Uninsulated FASTON
    FASTON Terminals Insulated and Uninsulated FASTON Terminals (Insulated and Uninsulated Tyco Electronics Corporation Harrisburg, Pennsylvania www.tycoelectronics.com 82004 Revised 07-2006 5M SK FP RoHS Ready FASTON Terminals (Insulated and Uninsulated) Page Head_12
    Original PDF
    114-2032
    Application Specification 114-2032 FASTON* Reversible Flag Receptacles 30 JUL 08 Rev B All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2 .
    Original PDF
    RoHS Ready FASTON Terminals and Connectors TYCO
    RoHS Ready FASTON Terminals and Connectors TYCO ELECTRONICS TECHNOLOGY PORTFOLIO ● Connector Systems / Electromechanical Components ● Relays ● Wireless ● Antennas, GPS Antennas, Integrated Antenna Systems ● Sensors ● Wire & Cable ● Resistors and Inductors
    Original PDF
    Catalog 82004 Revised 10-07 tycoelectronics.com
    Catalog 82004 Revised 10-07 tycoelectronics.com 82004–5M–LUG–FP–10-07 FASTON Terminals Insulated and Uninsulated Tyco Electronics Corporation Harrisburg, PA FASTON Terminals Insulated and Uninsulated Global Contacts FASTON Terminals (Insulated and Uninsulated)
    Original PDF