T1 SENSOR ELEME Search Results
T1 SENSOR ELEME Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| TCTH022BE | Toshiba Electronic Devices & Storage Corporation | Over Temperature Detection IC / VDD=1.7~5.5V / IPTCO=10μA / IDD=11.3μA / Open-drain type / FLAG signal latch function | Datasheet | ||
| TCTH021BE | Toshiba Electronic Devices & Storage Corporation | Over Temperature Detection IC / VDD=1.7~5.5V / IPTCO=10μA / IDD=11.3μA / Open-drain type | Datasheet | ||
| COMBOSENSOR | Texas Instruments | XTR117 XTR117 4-20mA Current Loop Transmitter |
|
||
| COMBOBODYSENSOR | Texas Instruments | ADS1292 Complete Low Power Integrated Analog Front End for ECG Applications |
|
||
| V62/20606-01EX | Texas Instruments | Enhanced product, low-power, analog temperature sensor |
|
|
Documents mentioning T1 SENSOR ELEME
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| immersion | 1 Immersion sensor 795 FTRL-T1 Immersion sensor for heating, ventilation and air conditioning systems. • T1 measuring element T1 • Fast response time • Cylindrical stainless immersion pocket • Immersion pocket length 420 mm Use The FTRL-T1 immersion temperature sensor is mainly used in hydraulic circuits in |
Original | ||||
| fr-t1 | 1 736 FR-T1/A Room temperature sensor Room sensor for HVAC systems for measurement of the air temperature • T1 measuring element • Suitable for wall mounting on all standard flush-mounting boxes FR-T1/A Technical data Application range 0… 50 °C Measuring element |
Original | ||||
| 1 656 PB-T1 Room temperature sensor Room sensor | 1 656 PB-T1 Room temperature sensor Room sensor for HVAC systems, for measurement of the air temperature • T1 measuring element • Suitable for wall mounting on all standard flush-mounting boxes • Socket for the PRONTO IRC ZS1 service terminal • Trimming potentiometer for |
Original | ||||
| fk-t1k | 1 775 FK-T1K.. Duct temperature sensor Sensor for measurement of duct air temperature in HVAC systems • T1 measuring element • Sensor probe easy to remove without dismantling sensor housing or disconnecting wiring • Fast response time • Plastic pipe between housing and |
Original | ||||
| ft-t1k1 | 1 Immersion temperature sensor 796 FT-T1K1 for hydraulic systems Immersion sensor for the measurement of water temperatures in hydraulic systems. • T1 sensing element • Fast response • Installed with immersion pocket Application The FT-T1K1 immersion temperature sensor is used primarily in HVAC hydraulic |
Original | ||||
| fs-t1l2 | 1 837 FS-T1L2, FS-T1L5 Probe sensor • T1 sensor element • Universally applicable as immersion, strap-on, wall surface or air temperature sensor • Suitable for retrofit and expansion of existing systems • An advanced forming process is used in the manufacture of the |
Original | ||||
| fw-t1g | 1 Outdoor sensor 819 FW-T1G for heating, ventilation and air conditioning systems Outdoor sensor for heating, ventilation and air conditioning systems – T1 measuring element – Attractive, stylish design – Easy to mount, firm connection Use The FW-T1G outdoor sensor is suitable for the measurement of the outside temperature |
Original | ||||
| fr-t1k | 1 735 FR-T1K Room temperature sensor Compact room sensor for measurement of the air temperature in conjunction with HVAC systems • T1 measuring element Suitable for wall-mounting Ideal where space is limited Discreet appearance FR-T1K Technical data |
Original | ||||
| fa-t1g | 1 Strap-on temperature sensor 809 FA-T1G for heating, ventilation and air conditioning systems Strap-on sensor for measurement of the water temperature in hydraulic systems – T1 measuring element – Optimum contact system – Reliable fixing arrangement (for pipe diameters of 15… 140 mm) |
Original | ||||
| solar sensor | 942 1 FS-T1 Solar Sensor The sensor measures the influence of solar irradiation on the heating of internal rooms. The sensor allows the flow temperature or the supply air temperature to be optimised for different sides of the building in order to reduce energy use and to |
Original | ||||
| lm10 | Laser Collimated Beam Sensor LM10 HL-C1 LH-50 Light / Reflective Type MEASUREMENT SENSORS LA SERIES LA-300 LA Light / Thru-beam Type HL-T1 ‘Class 1’ laser beam sensor safe for your eyes Conforming to EMC Directive (Excluding LA-C1) Safe laser beam Precise sensing in wide area |
Original | ||||
| 839 FIBER SENSORS LED Type Wafer Alignment Sensor | 839 FIBER SENSORS LED Type Wafer Alignment Sensor HD-T1 SERIES Related Information ■■General terms and conditions… F-17 ■■General precautions… P.1405 ■■Sensor selection guide… P.831~ LASER SENSORS |
Original | ||||
| ft-t1q | 1 Immersion temperature sensor 793 FT-T1Q… for fast-response measurement in hydraulic systems Immersion temperature sensors for fast-response measurements • T1 measuring element • Suitable for domestic water and other liquid media • For use in very fast-response controlled systems |
Original | ||||
| LED Type Optical Displacement Sensor LM10 HL-C1 | LED Type Optical Displacement Sensor LM10 HL-C1 LH-50 Light / Reflective Type MEASUREMENT SENSORS LH-50 SERIES LD LA-300 LA Light / Thru-beam Type HL-T1 Minute displacements measured with high precision by red ⅐⅐⅐ LED beam Conforming to EMC Directive |
Original | ||||
|
|
||||||
| displacement sensor | Matsushita Electric Works Micro Laser Displacement Sensor LM10 HL-C1 LH-50 Light / Reflective Type MEASUREMENT SENSORS LM10 HL-T1 The LM10 makes laser sensors super easy to use! Conforming to EMC Directive LA-300 LA Light / Thru-beam Type High-precision measurements, comparative output (amount of light / displacement) function |
Original | ||||
| pt100 | CombiTemp TFRH TM Hygienic – RTD temperature sensor Main features Pt100 sensor element, 2- or 4-wire Built in graphical display, CombiViewTM DFON optional Head mounted 4…20 mA transmitter, FlexTop type 22xx HART®, PA ATEX |
Original | ||||
| CombiTemp TFRN TM Industrial – RTD temperature | CombiTemp TFRN TM Industrial – RTD temperature sensor Main features Pt100 sensor element, ATEX Programmable by touch screen Easy and full programmable 2- or 4-wire HART®, PA Built in graphical display, CombiViewTM DFON optional |
Original | ||||
| hml1310 | PRODUCT NUMBER: DESCRIPTION: HML1310 L3100 × 1 ELEMENT LINEARIMAGE SENSOR ISSUE DATE: 01/19/1999 REVISED DATA: ∗under development. ∗perliminary. *THIS SPECIFICATION ARE SUBJECT TO BE CHANGED WITHOUT NOTICE. HUALON MICROELECTRONICS CORPORATION NO 1,R&D 4 TH RD. SCIENCE-BASED INDUSTRIAL PARK |
Original | ||||
| cysj106c | ChenYang Technologies GmbH & Co. KG CYSJ106C GaAs HALL-EFFECT ELEMENTS CYSJ106C series Hall-effect element is a ion-implanted magnetic field sensor made of monocrystal gallium arsenide (GaAs) semiconductor material group Ⅲ-V using ion-implanted technology. It can convert a magnetic flux density signal linearly into voltage output. |
Original | ||||
| FAM Data sheet Sensing element/Absolute ■Features | FAM Data sheet Sensing element/Absolute ■Features Barometric pressure measurable Surface mount package ■Ordering Information FAM-15P A SR Terminal leads configuration Model Surface mount package Rated Pressure (PSI) Pressure type |
Original | ||||
| cysj166a | ChenYang Technologies GmbH & Co. KG CYSJ166A GaAs HALL-EFFECT ELEMENTS CYSJ166A series Hall-effect element is a ion-implanted magnetic field sensor made of monocrystal gallium arsenide (GaAs) semiconductor material group Ⅲ-V using ion-implanted technology. It can convert a magnetic flux density signal linearly into voltage output. |
Original | ||||
| hq-8220 | InAs Quantum Well Hall Element HQ-8220 Shipped in packet-tape reel(5,000pcs per reel) Notice : It is requested to read and accept "IMPORTANT NOTICE" written on the back of the front cover of this catalogue. Y ●PRINCIPLE Magnet S HE1 By comparing the output voltage of each Hall elememt, position of the |