Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    STAEFA CONTROL Search Results

    STAEFA CONTROL Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    9519ADM/B
    Rochester Electronics LLC 9519A - Universal Interrupt Controller PDF Buy
    D8274
    Rochester Electronics LLC 8274 - Multi-Protocol Serial Controller (MPSC) PDF Buy
    MD82510/B
    Rochester Electronics LLC 82510 - Serial I/O Controller, CMOS, CDIP28 PDF Buy
    MD8259A/B
    Rochester Electronics LLC 8259A - Interrupt Controller, 8086, 8088, 80186 Compatible PDF Buy
    MR82510/B
    Rochester Electronics LLC 82510 - Serial I/O Controller, CMOS PDF Buy

    STAEFA CONTROL Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    staefa

    Abstract: Building Management System HVAC honeywell elm BMS SYSTEM HVAC Building Management System honeywell ZD-51001-BMS GENUS
    Contextual Info: BMS INTERFACE Datasheet ZD-51001-BMS Issue a : 17/5/96 Staefa Interface Unit Andover Interface Unit Elm BMS Interface Supervisor BMS System Description: The Building Management System BMS Interface communicates with Staefa, Andover or Utah HVAC systems. Their use enables HVAC to be reported via the


    Original
    ZD-51001-BMS 300mm 400mm 150mm 190754-JAS 190691-JAS 51002-BMS 51003-BMS staefa Building Management System HVAC honeywell elm BMS SYSTEM HVAC Building Management System honeywell ZD-51001-BMS GENUS PDF

    QFA81

    Abstract: staefa SIEMENS HYGROSTAT Landis landis and staefa relative humidity sensor circuit diagram "Humidity Sensor" siemens humidity sensor
    Contextual Info: 1 Room Hygrostats 513 QFA81. for relative humidity QFA81.1 QFA81 On / off hygrostat with microswitch, with humidity sensor, with plastic texture sensing strip good linearity, wide measuring range , for the control of humidification equipment, for the control of dehumidification equipment,


    Original
    QFA81. QFA81 QFA81 CM1N1513E 1513G01 1513M01 staefa SIEMENS HYGROSTAT Landis landis and staefa relative humidity sensor circuit diagram "Humidity Sensor" siemens humidity sensor PDF

    QVM62.1

    Abstract: QVM62 "Velocity Sensor" velocity sensor Siemens duct temperature sensor staefa Immersion sensors class 1K3 STAEFA "Air velocity Sensor" weight transducer for 10 kg
    Contextual Info: 1 1932P01 932 Air velocity sensor QVM62.1 Use This sensor is used to control the air velocity to a constant value, or to balance out pressure fluctuations supply or extract air control , or to monitor the flow in air ducts. It primarily is used for modulating fan control in primary plants to set the basic volume


    Original
    1932P01 QVM62 1932G01 1932M01 CM1N1932en QVM62.1 "Velocity Sensor" velocity sensor Siemens duct temperature sensor staefa Immersion sensors class 1K3 STAEFA "Air velocity Sensor" weight transducer for 10 kg PDF

    AlMgSi1

    Abstract: Differential Pressure siemens QBE64-dp4 staefa Landis Landis Staefa QBE siemens air pressure sensors AQB51 EN50081 QBE64
    Contextual Info: 1 921 Differential pressure sensor QBE64-DP4 for neutral and mildly corrosive liquids and gases Differential pressure sensor, suitable for gases or liquids, for the measurement of positive or negative pressures and pressure differentials in HVAC systems. • Measuring system based on ceramic lever technology


    Original
    QBE64-DP4 QBE64-DP4 EN50082-2 CA1N1921E AlMgSi1 Differential Pressure siemens staefa Landis Landis Staefa QBE siemens air pressure sensors AQB51 EN50081 QBE64 PDF

    VOC sensor

    Abstract: QPA84 automatic room power controller acetone gas sensor STAEFA "VOC Sensor" Siemens room temperature sensor landis and staefa 1571S02 1571S
    Contextual Info: 1 Indoor Air Quality Controller 571 QPA84 With integrated VOC 1 ) sensor, operating voltage AC 230 V, two-position output non-potential-free relay contact) 1) VOC = Volatile Organic Compounds Use In ventilation plant to optimize the indoor air quality and the consumption of energy by


    Original
    QPA84 QAP84 dampe0-2-11 1571G01 CM1N1571E 1571M01 VOC sensor QPA84 automatic room power controller acetone gas sensor STAEFA "VOC Sensor" Siemens room temperature sensor landis and staefa 1571S02 1571S PDF

    Siemens Ni1000 temperature sensor

    Abstract: landis staefa QAM22 staefa t1 sensor ni1000 Ni1000 temperature sensor Siemens QAM22 qam22 AQA61 EN50022-35 siemens qaa
    Contextual Info: 5 Signal transducer T1 for Ni1000 temperature sensor 142 AQA61.20 Signal transducer allowing the use of Ni1000 sensors for controllers with a T1 sensor input.  Converts an Ni1000 sensor signal into a T1-type output signal  Transducer supply from connected controller


    Original
    Ni1000 AQA61 QAM22 AQA61. IEC529 Siemens Ni1000 temperature sensor landis staefa QAM22 staefa t1 sensor Ni1000 temperature sensor Siemens QAM22 EN50022-35 siemens qaa PDF

    siemens air pressure sensors

    Abstract: QBE63-DP1 QBE63-DP01 landis and staefa Landis staefa Differential Pressure siemens QBE63-DP05 dp01 QBE63-DP02
    Contextual Info: 1 920 Differential pressure sensor QBE63-DP. for neutral and mildly corrosive liquids and gases Differential pressure sensor, suitable for gases and liquids, for the measurement of positive and negative pressures and pressure differentials in HVAC systems.


    Original
    QBE63-DP. EG89/336 EN50081-1, EN50081-2, EN50082-2 CA1N1920E siemens air pressure sensors QBE63-DP1 QBE63-DP01 landis and staefa Landis staefa Differential Pressure siemens QBE63-DP05 dp01 QBE63-DP02 PDF

    Siemens PT100 temperature sensor

    Abstract: PT100 temperature sensor PT100 temperature sensor data sheet pt100 temperature sensor circuit diagram Siemens duct temperature sensor PT100 temperature sensor datasheet DIN43729 PT100 connected diagram sensor PT100 siemens hvac
    Contextual Info: 1 Duct temperature sensor 778 FK-TP/200 for HVAC systems Duct temperature sensor for heating, ventilation and air conditioning systems – For use with controllers with Pt100 sensor inputs – In conjunction with MULTIREG and INTEGRAL RS. Use The FK-TP/200 duct temperature sensor can be used in air ducts for heating, ventilation


    Original
    FK-TP/200 Pt100 FK-TP/200 9M426 CA1N1778E Siemens PT100 temperature sensor PT100 temperature sensor PT100 temperature sensor data sheet pt100 temperature sensor circuit diagram Siemens duct temperature sensor PT100 temperature sensor datasheet DIN43729 PT100 connected diagram sensor PT100 siemens hvac PDF

    LG-Ni1000

    Abstract: Siemens Ni1000 temperature sensor Ni1000 temperature sensor Resistance characteristic Ni1000 ni1000 LG-Ni1000 connection QAD26 landis staefa 1802M01 1802G01
    Contextual Info: 1 Clamp-on Temperature Sensor 802 QAD26.220 Use Heating, ventilation, air conditioning and refrigeration plant. Acquisition of the medium temperature in pipes from −35 to +90 °C to provide measurement, limitation, compensation, or control. Ordering and


    Original
    QAD26 LG-Ni1000 Ni1000 LG-Ni1000 1802G01 1802M01 CM1N1802E Siemens Ni1000 temperature sensor Ni1000 temperature sensor Resistance characteristic Ni1000 ni1000 LG-Ni1000 connection landis staefa 1802M01 1802G01 PDF

    LG-Ni1000

    Abstract: temperature sensor Landis Ni 1000 polygyr Siemens Ni1000 temperature sensor staefa landis ni1000 lg-ni 1000 LG-Ni QAA64
    Contextual Info: 1 Room Temperature Sensor 722 QAA64 vandalproof though concealed mounting Use Acquisition of room temperature in spaces where the detector needs to be protected against damage or destruction by people. Such spaces are public buildings like schools, administrative buildings, multipurpose halls, etc.


    Original
    QAA64 QAA64 LG-Ni1000 1722G01 1722M01 CM1N1722E LG-Ni1000 temperature sensor Landis Ni 1000 polygyr Siemens Ni1000 temperature sensor staefa landis ni1000 lg-ni 1000 LG-Ni PDF

    staefa

    Abstract: Landis Siemens room temperature sensor QAA32 NTC Siemens ntc resistor Siemens temperature sensor landis and staefa NTC SIEMENS K 30 landis and staefa temperature
    Contextual Info: 1 747 Room Temperature Sensor QAA32 NTC resistor sensing element Use In HVAC plants to acquire the room temperature. Functions 1747D01 Ω 9000 7000 5000 The sensor acquires the room temperature by means of its NTC resistor. The resistance value changes according to the ambient


    Original
    QAA32 1747D01 ARG70 ARG70 0502-G 1747G01 QAA32 CE1N1747en 3001M02 staefa Landis Siemens room temperature sensor NTC Siemens ntc resistor Siemens temperature sensor landis and staefa NTC SIEMENS K 30 landis and staefa temperature PDF

    polygyr

    Abstract: QBE61 qbe61.2 Landis PN40 water differential pressure sensor chilled water system landis and staefa Differential Pressure siemens siemens humidity sensor
    Contextual Info: 1 Differential Pressure Sensor 915 QBE61.2-dp0,5 This sensor delivering an active measuring signal of DC 0.10 V and works on a AC 24 V operating voltage. Measuring ranges between 0 and 0.5 bar differential pressure. Application Sensing of differential pressure in heating, ventilating and air conditioning plants.


    Original
    QBE61 1915G01 CM1N1915E 1901M02E 1915M01 CM1N3463E polygyr qbe61.2 Landis PN40 water differential pressure sensor chilled water system landis and staefa Differential Pressure siemens siemens humidity sensor PDF

    qbe*61.1

    Abstract: QBE61 landis qbe61.1-p20 polygyr QBE61.1 pressure sensor landis qbe61,1 p20 staefa Landis siemens r134a QBE61 p2
    Contextual Info: 1 Pressure Detectors 901 QBE61.1. Active pressure detector delivering a DC 0.10 V measuring signal and operating on AC 24 V. There are five different versions available, with measuring ranges between 0 and 40 bar. Application Measuring and sensing of overpressure in heating, ventilating and air conditioning


    Original
    QBE61 CM1N1901E 1901G01 1901M03E 1901M02E 1901M01 CM1N3461E qbe*61.1 landis qbe61.1-p20 polygyr QBE61.1 pressure sensor landis qbe61,1 p20 staefa Landis siemens r134a QBE61 p2 PDF

    QBE61

    Abstract: water differential pressure sensor QBE61.3 DP10 landis and staefa steam trap Landis STAEFA staefa dp2 staefa temperature sensors landis staefa
    Contextual Info: 1 1923P01 923 Differential pressure sensors QBE61.3-DP. for neutral or slightly aggressive gases and liquids • • • • • • Operating voltage AC 24 V or DC 18.33 V Output signal DC 0.10 V Connecting male thread G ½" 3 versions covering a total differential pressure range of 0 … 10 bar


    Original
    1923P01 QBE61 1923G01 1923M01 1923M02E CM1N1923en water differential pressure sensor QBE61.3 DP10 landis and staefa steam trap Landis STAEFA staefa dp2 staefa temperature sensors landis staefa PDF

    Siemens QFM65

    Abstract: QFM65 temperature sensor Landis Ni 1000 staefa qfm65 Siemens duct temperature controller staefa t1 sensor QFM65-1 siemens hvac qfm65 STAEFA Building Management System
    Contextual Info: 1 1860P01 860 QFM65.1 Duct sensor for relative humidity and temperature Operating voltage AC 24 V Signal output DC 0.10 V for relative humidity Signal output L&S Ni 1000 passive for temperature Measurement accuracy ± 3 % r. h. within the comfort range


    Original
    1860P01 QFM65 1860M01 1860M02 CM1N1860en Siemens QFM65 temperature sensor Landis Ni 1000 staefa qfm65 Siemens duct temperature controller staefa t1 sensor QFM65-1 siemens hvac qfm65 STAEFA Building Management System PDF

    CH-8712

    Abstract: STAEFA ag ch-8712
    Contextual Info: Sample Code I2C For communication with the SHT3x Humidity and Temperature Sensor through the I2C Interface Introduction This document contains sample code in C for communication with the SHT3x humidity and temperature sensor through the I2C Interface. The purpose of the code is to ease the user’s software programming when implementing SHT3x sensors. Besides


    Original
    STM32-Discovery CH-8712 STAEFA ag ch-8712 PDF

    Siemens PT100 temperature sensor

    Abstract: PT 2000 temperature sensor PT100 temperature sensor class B PT100 DIN PT100 temperature sensor water pt 100 sensor technical data siemens PT100 temperature sensor long sensing element PT100 surface temperature sensor signal conditioning circuit for pt100 pt100 siemens
    Contextual Info: 1 804 Clamp-on temperature sensor QAD100.1 Use The sensor is used for acquiring the medium temperature on the surface of pipes e.g. the heating water in heating, ventilation or air conditioning plants . It is designed for use in connection with automation equipment, display and logging


    Original
    QAD100 Pt100 1804G01 Pt100 1804M01 CM1N1804en Siemens PT100 temperature sensor PT 2000 temperature sensor PT100 temperature sensor class B PT100 DIN PT100 temperature sensor water pt 100 sensor technical data siemens PT100 temperature sensor long sensing element PT100 surface temperature sensor signal conditioning circuit for pt100 pt100 siemens PDF

    solar sensor

    Abstract: Solar sun sensor SUN SENSOR staefa t1 sensor Siemens room temperature sensor staefa Landis siemens air temperature sensors Siemens flow sensor solar radiation sensor
    Contextual Info: 942 1 FS-T1 Solar Sensor The sensor measures the influence of solar irradiation on the heating of internal rooms. The sensor allows the flow temperature or the supply air temperature to be optimised for different sides of the building in order to reduce energy use and to


    Original
    S1-02 9D728 CA1N1942E solar sensor Solar sun sensor SUN SENSOR staefa t1 sensor Siemens room temperature sensor staefa Landis siemens air temperature sensors Siemens flow sensor solar radiation sensor PDF

    johnson motor

    Abstract: SGF24 DANFOSS satchwell siemens ICA STAEFA
    Contextual Info: RS 824-705 BELIMO NM 24-SR damper motor 8 Nm Dampers up to approx. 1.5 m2 Modulating damper motor 24 VAC Control 0.10 VDC and position feedback 2.10V D C Self-adapting, automatic angleof-rotation and running-time adjustment Improved functional safety


    OCR Scan
    24-SR 10VDC 24-SR johnson motor SGF24 DANFOSS satchwell siemens ICA STAEFA PDF

    NM230-F

    Abstract: STAEFA damper actuator DANFOSS NM24-SR-F NM24-SR satchwell EEC AEG 89/336/EEC
    Contextual Info: B C NM230-F Form-fit damper actuator 8 Nm Dampers up to approx. 1.5 m2 Open/Close actuator AC 230 V Control by single-pole contact (single-wire control) p0024707 Improved functional safety The damper actuator has no limit switches and is overload-proof. It stops automatically when it reaches the damper or


    Original
    NM230-F p0024707 NM230-F, 89/336/EEC, 92/31/EEC, 93/68/EEC d0014902 STAEFA damper actuator DANFOSS NM24-SR-F NM24-SR satchwell EEC AEG 89/336/EEC PDF

    CH-8712

    Abstract: staefa CH-8712 ELTEC staefa RS 101 reference eltec infrared pyroelectric, gas ELTEC INSTRUMENTS
    Contextual Info: Model 481 Miniature Single Element Pyroelectric IR Detector With Source Follower Manufactured under one or more of the following U.S. patents: 3,839,640 - 4,218,620 - 4,326,663 - 4,384,207 - 4,437,003 - 4,441,023 - 4,523,095 Model 481 contains a single lithium


    Original
    CH-8712 staefa CH-8712 ELTEC staefa RS 101 reference eltec infrared pyroelectric, gas ELTEC INSTRUMENTS PDF

    ELTEC INSTRUMENTS

    Abstract: CH-8712 staefa CH-8712 Pyroelectric Detectors
    Contextual Info: Model 482 High Gain Thermally Compensated Pyroelectric IR Detector Manufactured under one or more of the following U.S. patents: 3,839,640 - 4,218,620 - 4,326,663 - 4,384,207 - 4,437,003 - 4,441,023 - 4,523,095 Model 482 consists of two lithium tantalate sensing elements, a load


    Original
    CH-8712 ELTEC INSTRUMENTS staefa CH-8712 Pyroelectric Detectors PDF

    eltec 406

    Abstract: CH-8712 DS406 STAEFA
    Contextual Info: Model 406 Single Element Pyroelectric IR Detector With Source Follower Manufactured under one or more of the following U.S. patents: 3,839,640 - 4,218,620 - 4,326,663 - 4,384,207 - 4,437,003 - 4,441,023 - 4,523,095 Model 406 contains a single lithium tantalate sensing element and a JFET


    Original
    CH-8712 DS406 E-03/2006) eltec 406 DS406 STAEFA PDF

    CH-8712

    Contextual Info: Model 429 Twin Channel Pyroelectric IR Detector with JFET Amplifier Manufactured under one or more of the following U.S. patents: 3,839,640 - 4,218,620 - 4,326,663 - 4,384,207 - 4,437,003 - 4,441,023 - 4,523,095 Model 429 consists of two lithium tantalate sensing elements, each with


    Original
    CH-8712 PDF