Contextual Info: 2460 ELECTRONIC SPARK TIMING The ULQ2460A, ULQ2460C, and ULQ2460LW electronic spark timing circuits are intended to interface between conventional electro magnetic pick-ups, a computer-controlled electronic spark timing EST computer, and a high-efficiency ignition coil.
|
OCR Scan
|
ulq2460aulq2460culq2460lwps-014 |
PDF
|
EPCOS CS 230
Abstract: spark gap CAS02X-067
Contextual Info: Switching Spark Gap CAS02X-067 Ordering code: B88069X0670T502 DC spark-over voltage 1 2) 200 . 250 V Initial values Ignition time tI after 150 hours in darkness 3) at –20 °C at +25; 125 °C Electrical life time Maximum increase of DC spark-over voltage
|
Original
|
cas02x-067b88069x0670t502epcos cs 230spark gap |
PDF
|
spark gap
Abstract: EPCOS CS 230 Spark CAS02X-091
Contextual Info: Switching Spark Gap CAS02X-091 Ordering code: B88069X0910T502 DC spark-over voltage 1 2) 190 . 220 V Initial values Ignition time tI after 150 hours in darkness 3) at –20 °C at +25; 125 °C Electrical life time Maximum increase of DC spark-over voltage
|
Original
|
cas02x-091b88069x0910t502spark gapepcos cs 230+1spark
|
PDF
|
spark gap
Abstract: CAS02X-047
Contextual Info: Switching Spark Gap CAS02X-047 Ordering code: B88069X0470T502 DC spark-over voltage 1 2) 215 . 240 V Initial values Ignition time tI after 150 hours in darkness 3) at –20 °C at +25; 125 °C Electrical life time Maximum increase of DC spark-over voltage
|
Original
|
cas02x-047b88069x0470t502spark gap |
PDF
|
spark gap
Abstract: B88069X0680 CAS02X-068 EPCOS CS 230 B88069X0680T502
Contextual Info: Switching Spark Gap CAS02X-068 Ordering code: B88069X0680T502 DC spark-over voltage 1 2) 200 . 255 V Initial values Ignition time tI after 150 hours in darkness 3) at –20 °C at +25; 125 °C Electrical life time Maximum increase of DC spark-over voltage
|
Original
|
cas02x-068b88069x0680t502spark gapb88069x0680+1epcos cs 230
|
PDF
|
EPCOS 230 06 O
Abstract: spark gap CAS02X-069 EPCOS CS 230
Contextual Info: Switching Spark Gap CAS02X-069 Ordering code: B88069X0690T502 DC spark-over voltage 1 2) 205 . 230 V Initial values Ignition time tI after 150 hours in darkness 3) at –20 °C at +25; 125 °C Electrical life time Maximum increase of DC spark-over voltage
|
Original
|
cas02x-069b88069x0690t502epcos 230 06 ospark gap+1epcos cs 230
|
PDF
|
EPCOS CS 230
Abstract: spark gap CAS02X-087
Contextual Info: Switching Spark Gap CAS02X-087 Ordering code: B88069X0870T502 DC spark-over voltage 1 2) 180 . 230 V Initial values Ignition time tI after 150 hours in darkness 3) at –20 °C at +25; 125 °C Electrical life time Maximum increase of DC spark-over voltage
|
Original
|
cas02x-087b88069x0870t502epcos cs 230spark gap |
PDF
|
ignition spark
Abstract: spark gap cas02xg Spark EPCOS CS 230
Contextual Info: Switching Spark Gap CAS02XG Ordering code: B88069X0680T502 DC spark-over voltage 1 2) 200 . 255 V Initial values Ignition time tI after 150 hours in darkness 3) at –20 °C at +25; 125 °C Electrical life time Maximum increase of DC spark-over voltage
|
Original
|
cas02xgb88069x0680t502ignition sparkspark gap+2sparkepcos cs 230
|
PDF
|
spark gap
Abstract: CAS02X-093 EPCOS CS 230
Contextual Info: Switching Spark Gap CAS02X-093 Ordering code: B88069X0930T502 DC spark-over voltage 1 2) 180 . 220 V Initial values Ignition time tI after 150 hours in darkness 3) at –20 °C at +25; 125 °C Electrical life time Maximum increase of DC spark-over voltage
|
Original
|
cas02x-093b88069x0930t502spark gapepcos cs 230 |
PDF
|
crankshaft position
Abstract: electronic circuit diagram UPS
Contextual Info: 2460 E LE C TR O N IC SPARK TIM IN G The ULQ2460A and ULQ 2460LW electronic spark timing circuits are intended to interface between conventional electrom agnetic pick ups, a com puter-controlled electronic spark timing EST computer, and a high-efficiency ignition coil.
|
OCR Scan
|
ulq2460a2460lw460a/lwcrankshaft position+1electronic circuit diagram ups
|
PDF
|
EPCOS 230 03 O
Abstract: spark gap EPCOS CS 230 B88069X4290T502 CAS02X-429
Contextual Info: Switching Spark Gap CAS02X-429 Ordering code: B88069X4290T502 DC spark-over voltage 1 2) 235 . 260 V Initial values Ignition time tI after 150 hours in darkness 3) at –20 °C at +25; 125 °C Electrical life time A Maximum increase of DC spark-over voltage
|
Original
|
cas02x-429b88069x4290t502epcos 230 03 ospark gap+1epcos cs 230
|
PDF
|
crank angle position sensors
Abstract: Triggered spark gap cop ignition driver crank positioning sensor motorola transistor ignition spark plugs MPC555
Contextual Info: S PA R K A Motorola Low-Level Driver Component Overview The Spark driver, one of the low-level driver components, is designed to generate spark timing output pulses, which are used to charge an ignition coil and ignite a spark plug. The timing of these output pulses is dependent upon engine
|
Original
|
oe-39crank angle position sensorstriggered spark gapcop ignition driver+4crank positioning sensormotorola transistor ignitionspark plugsmpc555
|
PDF
|
cop ignition driver
Abstract: Triggered spark gap pulse IGNITION Motorola ignition coil driver motorola dis ignition driver spark plugs driver ignition coil motorola transistor ignition spark ignition drivers
Contextual Info: S PA R K A Motorola Low-Level Driver Component Overview The Spark driver, one of the low-level driver components, is designed to generate spark timing output pulses, which are used to charge an ignition coil and ignite a spark plug. The timing of these output pulses is
|
Original
|
oe-39cop ignition drivertriggered spark gappulse ignition+7motorola ignition coil drivermotorola dis ignition driverspark plugsdriver ignition coilmotorola transistor ignitionsparkignition drivers
|
PDF
|
EPCOS 230 09 O
Abstract: capacitor discharge ignition B88069X0710 EPCOS CS 230 spark gap CAS02X-071 B88069X0710T502
Contextual Info: Switching Spark Gap CAS02X-071 Ordering code: B88069X0710T502 DC spark-over voltage 1 2) 215 . 255 V Initial values Ignition time tI after 150 hours in darkness 3) 95 99.9 ≤4 ≤2 at –20 °C at +25; 125 °C Electrical life time A Maximum increase of DC spark-over voltage
|
Original
|
cas02x-071b88069x0710t502epcos 230 09 ocapacitor discharge ignition+3b88069x0710epcos cs 230spark gap
|
PDF
|
|
|
B88069X
Abstract: SURGE ARRESTER EPCOS 230 07 0 SURGE ARRESTER EPCOS 350 07 0 E163070 diode T87A B88069X FREE SHIPPING On May-14-13 at 01:17:47 PDT, seller added the following information: F health data sheet egypt
Contextual Info: EPCOS Product Profile 2015 Surge Arresters and Switching Spark Gaps Überspannungsableiter und Schaltfunkenstrecken www.epcos.com Surge Arresters and Switching Spark Gaps Überspannungsableiter und Schaltfunkenstrecken Contents Inhalt Important notes Wichtige Hinweise
|
Original
|
b88069xsurge arrester epcos 230 07 0surge arrester epcos 350 07 0e163070+3diode t87ab88069x free shipping on may-14-13 at 01:17:47 pdt, seller added the following information: fhealth data sheet egypt
|
PDF
|
80A230
Abstract: 80A600 80A350 80A470 C80AL 80A250 sw 3600 80A400 80A90 80A35
Contextual Info: A Series 80 SW type Nominal dc spark-over voltage Gas Discharge Tube dc Maximum Ignition spark-over voltage Frequency Switching Operations Insulation resistance Part No. Vsdc (V) Vsdc (V) 80A230 230 184~276 100 80A250 250 200~300 100 80A300 300 240~360 100
|
Original
|
80a23080a25080a30080a350+1080a40080a4201x10580a47080a60080a700c80alsw 360080a9080a35
|
PDF
|
igniter transformer
Abstract: xenon hid ballast xenon lamp igniter gas cooker circuit ignitor Ignition Transformer xenon igniter xenon ballast pulse IGNITION Epcos spark gap spark gap ignitor
Contextual Info: Switching Spark Gaps Schaltfunkenstrecken Basic circuit pulse igniter Prinzipschaltkreis Impulszündgerät R C General Switching spark gap Schaltfunkenstrecke Load Last RAB0223-W Fig. / Bild 1 General technical information It is increasingly common practice to
|
Original
|
rab0223-wigniter transformerxenon hid ballastxenon lamp igniter+7gas cooker circuit ignitorignition transformerxenon igniterxenon ballastpulse ignitionepcos spark gapspark gap ignitor
|
PDF
|
epcos EC 90 11 O
Abstract: EPCOS 470 11 O em epcos 3000 Epcos 5000 11 O epcos EC 90 14 O EPCOS 1400 14 O epcos SURGE ARRESTERS gas discharge epcos 260 11 EPCOS ec 600 10 O EPCOS 350 10 O
Contextual Info: Arresters Surge Arresters Switching Spark Gaps Überspannungsableiter Surge Arresters 2-Elektroden-Ableiter 2-electrode surge arresters Nennansprechgleichspannung DC spark-over voltage V Light duty EM M5 EC Medium duty N8 A7 L7 4500 Heavy duty A8 A83 2,5/2,5
|
Original
|
epcos ec 90 11 oepcos 470 11 oem epcos 3000epcos 5000 11 o+6epcos ec 90 14 oepcos 1400 14 oepcos surge arrestersgas discharge epcos 260 11epcos ec 600 10 oepcos 350 10 o
|
PDF
|
EPCOS 230
Abstract: cm 230 spark gap CAM02X Epcos spark gap EPCOS 230 03 O
Contextual Info: Switching Spark Gap CAM02X Ordering code: B88069X5410T502 DC spark-over voltage 1 2) 230 ± 15 V % Initial values Ignition time tI after 24 hours in darkness 3) 95 ≤4 ≤2 at –20 °C at +25; 125 °C Electrical life time Switching operations at +25; 125 °C
|
Original
|
cam02xb88069x5410t502epcos 230cm 230+3spark gapepcos spark gapepcos 230 03 o
|
PDF
|
|
Contextual Info: TX Series Triggered Spark Gaps Features • Rugged ceramic-metal construction • Short delay times • Miniature size • High reliability Description The TX is a series of miniature triggered spark gaps designed for high reliability switching with Main Static
|
Original
|
|
PDF
|
MPC55xx
Abstract: AN2864 AN3771
Contextual Info: Freescale Semiconductor Application Note Using the eTPU Spark Function by: Bill Terry MSG 32-bit Automotive Applications Engineering USA, Austin 1 Introduction This application note is intended to accompany the simple C interface functions for the eTPU SPARK
|
Original
|
32-bitmpc55xxmpc563xman2864--general+3an3768an2864an3771
|
PDF
|
|
Contextual Info: BX Series Spark Gaps Description The BX series of miniature two electrode spark gaps 2.0-20.0kV has been designed for applications that have severe environment and high reliability requirements. These gaps are made with high alumina (Al2O3) ceramic cylinders and metal
|
Original
|
|
PDF
|
spark gap switch
Abstract: Triggered spark gap
Contextual Info: Mini-Triggered Spark Gaps & Transformers Key Features • • • • • High reliability Extremely low jitter Environmentally durable Small size Matching trigger transformers Applications • • • • Excelitas’ Mini-Triggered Spark Gaps are designed for high reliabilty switching up to 4 kV
|
Original
|
spark gap switchtriggered spark gap |
PDF
|
AN3771
Abstract: spark AN2864
Contextual Info: Freescale Semiconductor Application Note Document Number: AN3771 Rev. 0, 07/2009 Using the eTPU Spark Function by: Bill Terry MSG 32-bit Automotive Applications Engineering USA, Austin 1 Introduction This application note is intended to accompany the simple C interface functions for the eTPU SPARK
|
Original
|
an377132-bitmpc55xxmpc563xm+4an2864--generalan3768sparkan2864
|
PDF
|