    SPARK GAP SWITCH Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    ICL7662MTV/B
    Rochester Electronics LLC ICL7662 - Switched Capacitor Converter, 10kHz Switching Freq-Max, CMOS PDF Buy
    ICL7660SMTV
    Rochester Electronics LLC ICL7660 - Switched Capacitor Converter, 0.02A, 17.5kHz Switching Freq-Max, CMOS, MBCY8 PDF Buy
    LM1578AH/883
    Rochester Electronics LLC LM1578 - Switching Regulator, Current-mode, 0.75A, 100kHz Switching Freq-Max, MBCY8 - Dual marked (5962-8958602GA) PDF Buy
    DG201AK/B
    Rochester Electronics LLC DG201A - 15.0V SPST CMOS Switch PDF Buy
    IH5012CDE
    Rochester Electronics LLC IH5012 - SPST, 4 Func, 1 Channel, CDIP16 PDF Buy

    SPARK GAP SWITCH Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    spark gap

    Abstract: BK2XX03502 BK2XX01502 Wire functions by color BK2 25 resistor color code
    Contextual Info: SPark Gap Protectors BK2 Series SPark Gap Protectors (BK2 Series) FEATURES Equipment where Anti-Static is required (BK2 or BK3 Series) Displays, including TV Monitors Dusty and flammable environments Medical Equipment and Devices (BK1, BK2 or BK3 Series)


    Original
    10secbk2xx03502bk2xx03002bk2xx02502+6bk2xx02002spark gapbk2xx01502wire functions by colorbk2 25resistor color code PDF

    spark gap

    Abstract: spark gap switch UL1449 BK-1
    Contextual Info: SPark Gap Protectors BK1 Series SPark Gap Protectors (BK1 Series) FEATURES Equipment where Anti-Static is required (BK2 or BK3 Series) Displays, including TV Monitors Dusty and flammable environments Medical Equipment and Devices (BK1, BK2 or BK3 Series)


    Original
    ul1449125/min10secspark gap+2spark gap switchbk-1 PDF

    spark gap

    Abstract: BK3XX00702 spark gap switch BK2 20 compressor ic
    Contextual Info: SPark Gap Protectors BK3 Series SPark Gap Protectors (BK3 Series) FEATURES Compared to other surge absorbers with similar functions, this range has the fastest response speed, can withstand the largest current and is the smallest. Zero leaking current before clamping voltage


    Original
    10secbk3xx03502bk3xx03002bk3xx02502+6bk3xx02002spark gapbk3xx00702spark gap switchbk2 20compressor ic PDF

    SPARK GAP

    Abstract: CAS06XG spark gap 100 kv
    Contextual Info: Switching Spark Gap CAS06XG Ordering code: B88069X1210T502 Preliminary data DC spark-over voltage 1 2) 350 . 900 V Impulse spark-over voltage at 100 V/µs - for 99 % of measured values - typical values of distribution < 1100 < 1000 V V < 1400 < 1300 V V


    Original
    cas06xgb88069x1210t50257845/vde0845spark gap+1spark gap 100 kv PDF

    spark gap

    Abstract: 100 kv spark gap spark switching spark gap CAS06XG
    Contextual Info: Switching Spark Gap CAS06XG Ordering code: B88069X1210T502 Preliminary data DC spark-over voltage 1 2) 350 . 900 V Impulse spark-over voltage at 100 V/µs - for 99 % of measured values - typical values of distribution < 1100 < 1000 V V < 1400 < 1300 V V


    Original
    cas06xgb88069x1210t50257845/vde0845spark gap+3100 kv spark gapsparkswitching spark gap PDF

    spark gap

    Abstract: spark gap switch UL947A
    Contextual Info: SPark Gap Protectors BK1-M Series SPark Gap Protectors (BK1-M Series) FEATURES Compared to other surge absorbers with similar functions, this range has the fastest response speed, can withstand the largest current and is the smallest. Zero leaking current before clamping voltage


    Original
    125/min10secspark gapspark gap switch+1ul947a PDF

    spark gap

    Abstract: spark gap switch BK2 25
    Contextual Info: SPark Gap Protectors BK2-M Series SPark Gap Protectors (BK2-M Series) FEATURES APPLICATIONS For Power Supplies (BK1 or BK2 Series) Standard power supplies, as required by US UL1449 Highly-rated power supplies Two or three-phase industrial or civil equipment power


    Original
    ul1449125/min10secspark gap+2spark gap switchbk2 25 PDF

    spark gap

    Abstract: UL1449 compressor ic spark gap switch
    Contextual Info: SPark Gap Protectors BK3-M Series SPark Gap Protectors (BK3-M Series) FEATURES APPLICATIONS For Power Supplies (BK1 or BK2 Series) Standard power supplies, as required by US UL1449 Highly-rated power supplies Two or three-phase industrial or civil equipment power


    Original
    ul1449125/min10secspark gap+2compressor icspark gap switch PDF

    EPCOS CS 230

    Abstract: spark gap CAS02X-067
    Contextual Info: Switching Spark Gap CAS02X-067 Ordering code: B88069X0670T502 DC spark-over voltage 1 2) 200 . 250 V Initial values Ignition time tI after 150 hours in darkness 3) at –20 °C at +25; 125 °C Electrical life time Maximum increase of DC spark-over voltage


    Original
    cas02x-067b88069x0670t502epcos cs 230spark gap PDF

    spark gap

    Abstract: CAS02X-047
    Contextual Info: Switching Spark Gap CAS02X-047 Ordering code: B88069X0470T502 DC spark-over voltage 1 2) 215 . 240 V Initial values Ignition time tI after 150 hours in darkness 3) at –20 °C at +25; 125 °C Electrical life time Maximum increase of DC spark-over voltage


    Original
    cas02x-047b88069x0470t502spark gap PDF

    spark gap

    Abstract: B88069X0680 CAS02X-068 EPCOS CS 230 B88069X0680T502
    Contextual Info: Switching Spark Gap CAS02X-068 Ordering code: B88069X0680T502 DC spark-over voltage 1 2) 200 . 255 V Initial values Ignition time tI after 150 hours in darkness 3) at –20 °C at +25; 125 °C Electrical life time Maximum increase of DC spark-over voltage


    Original
    cas02x-068b88069x0680t502spark gapb88069x0680+1epcos cs 230 PDF

    EPCOS 230 06 O

    Abstract: spark gap CAS02X-069 EPCOS CS 230
    Contextual Info: Switching Spark Gap CAS02X-069 Ordering code: B88069X0690T502 DC spark-over voltage 1 2) 205 . 230 V Initial values Ignition time tI after 150 hours in darkness 3) at –20 °C at +25; 125 °C Electrical life time Maximum increase of DC spark-over voltage


    Original
    cas02x-069b88069x0690t502epcos 230 06 ospark gap+1epcos cs 230 PDF

    spark gap

    Abstract: SONG LONG surge absorber crt monitor circuit diagram Spark microwave oven inverter DL-41 microwave oven crt tube spark absorber
    Contextual Info: 嵩隆電子股份有限公司 SAS SONG LONG ELECTRONICS CO., LTD. SAS Spark Gap Surge Absorber Scope Spark Gap ( Surge Absorber ) devices are constructed with a micro-gap element that base on semi-conductor technology. Assembly in a clean room with glass tube encapsulation of percentage of gas. This gas accurately


    Original
    tel100mdl-35dl-41spark gap+8song longsurge absorbercrt monitor circuit diagramsparkmicrowave oven invertermicrowave ovencrt tubespark absorber PDF

    spark gap

    Abstract: EPCOS CS 230 Spark CAS02X-091
    Contextual Info: Switching Spark Gap CAS02X-091 Ordering code: B88069X0910T502 DC spark-over voltage 1 2) 190 . 220 V Initial values Ignition time tI after 150 hours in darkness 3) at –20 °C at +25; 125 °C Electrical life time Maximum increase of DC spark-over voltage


    Original
    cas02x-091b88069x0910t502spark gapepcos cs 230+1spark PDF

    ignition spark

    Abstract: spark gap cas02xg Spark EPCOS CS 230
    Contextual Info: Switching Spark Gap CAS02XG Ordering code: B88069X0680T502 DC spark-over voltage 1 2) 200 . 255 V Initial values Ignition time tI after 150 hours in darkness 3) at –20 °C at +25; 125 °C Electrical life time Maximum increase of DC spark-over voltage


    Original
    cas02xgb88069x0680t502ignition sparkspark gap+2sparkepcos cs 230 PDF

    spark gap

    Abstract: CAS02X-093 EPCOS CS 230
    Contextual Info: Switching Spark Gap CAS02X-093 Ordering code: B88069X0930T502 DC spark-over voltage 1 2) 180 . 220 V Initial values Ignition time tI after 150 hours in darkness 3) at –20 °C at +25; 125 °C Electrical life time Maximum increase of DC spark-over voltage


    Original
    cas02x-093b88069x0930t502spark gapepcos cs 230 PDF

    EPCOS 230 03 O

    Abstract: spark gap EPCOS CS 230 B88069X4290T502 CAS02X-429
    Contextual Info: Switching Spark Gap CAS02X-429 Ordering code: B88069X4290T502 DC spark-over voltage 1 2) 235 . 260 V Initial values Ignition time tI after 150 hours in darkness 3) at –20 °C at +25; 125 °C Electrical life time A Maximum increase of DC spark-over voltage


    Original
    cas02x-429b88069x4290t502epcos 230 03 ospark gap+1epcos cs 230 PDF

    igniter transformer

    Abstract: xenon hid ballast xenon lamp igniter gas cooker circuit ignitor Ignition Transformer xenon igniter xenon ballast pulse IGNITION Epcos spark gap spark gap ignitor
    Contextual Info: Switching Spark Gaps Schaltfunkenstrecken Basic circuit pulse igniter Prinzipschaltkreis Impulszündgerät R C General Switching spark gap Schaltfunkenstrecke Load Last RAB0223-W Fig. / Bild 1 General technical information It is increasingly common practice to


    Original
    rab0223-wigniter transformerxenon hid ballastxenon lamp igniter+7gas cooker circuit ignitorignition transformerxenon igniterxenon ballastpulse ignitionepcos spark gapspark gap ignitor PDF

    017nf

    Abstract: Okaya rodan okaya Okaya Electric Industries 100C switching spark gap spark gap Okaya LE
    Contextual Info: Spec No. Data Version SS-022 Oct 30, 2003 First P: 1/5 SPECIFICATION Product name : Rodan Spark Gap Type : RSG-302-BKL OKAYA ELECTRIC AMERICA, INC. Spec No. Data Version SS-022 Oct 30, 2003 First 1. Scope P: 2/5 This specification covers Rodan Spark Gap RSG-302-BKL.


    Original
    ss-022rsg-302-bkl4r-4198-y85017nf+7okayarodan okayaokaya electric industries100cswitching spark gapspark gapokaya le PDF

    B88069X1200T502

    Abstract: CAS04XG
    Contextual Info: Switching Spark Gap CAS04XG Ordering code: B88069X1200T502 Preliminary data DC spark-over voltage 1 2) 350 . 550 V Impulse spark-over voltage at 100 V/µs - for 99 % of measured values - typical values of distribution < 900 < 800 V V < 1200 < 1100 V V Insulation resistance at 300 Vdc


    Original
    cas04xgb88069x1200t50257845/vde0845 PDF

    CAS04XG

    Abstract: spark gap B88069X1200T502 spark gap 100 kv Epcos spark gap OCS400 100 kv spark gap
    Contextual Info: Switching Spark Gap CAS04XG Ordering code: B88069X1200T502 Preliminary data DC spark-over voltage 1 2) 350 . 550 V Impulse spark-over voltage at 100 V/µs - for 99 % of measured values - typical values of distribution < 900 < 800 V V < 1200 < 1100 V V Insulation resistance at 300 Vdc


    Original
    cas04xgb88069x1200t50257845/vde0845spark gap+4spark gap 100 kvepcos spark gapocs400100 kv spark gap PDF

    Okaya

    Abstract: 100C 4R-4198-Y85 4r4198
    Contextual Info: Spec No. Data Version SS-023 Oct 30, 2003 First P: 1/5 SPECIFICATION Product name : Rodan Spark Gap Type : RSG-502-BKL OKAYA ELECTRIC AMERICA, INC. Spec No. Data Version SS-023 Oct 30, 2003 First 1. Scope P: 2/5 This specification covers Rodan Spark Gap RSG-502-BKL.


    Original
    ss-023rsg-502-bkl4r-4198-y85okaya+2100c4r4198 PDF

    ez 802

    Abstract: Okaya Electric Industries rodan okaya spark gap 4r4198
    Contextual Info: Spec No. Data Version SS-024 Oct 30, 2003 First P: 1/5 SPECIFICATION Product name Rodan Spark Gap Type RSG-802-BQL OKAYA ELECTRIC AMERICA, INC. Spec No. Data Version SS-024 Oct 30, 2003 First 1. Scope P: 2/5 This specification covers Rodan Spark Gap RSG-802-BQL.


    Original
    ss-024rsg-802-bql4r-4198-y89ez 802+4okaya electric industriesrodan okayaspark gap4r4198 PDF

    spark gap 801

    Abstract: PC 801 S Okaya Okaya Electric Industries 100C X101 RSG-801-BJL
    Contextual Info: Spec No. Data Version SS-020 Oct 30, 2003 First P: 1/5 SPECIFICATION Product name :Rodan Spark Gap Type : RSG-801-BJL OKAYA ELECTRIC AMERICA, INC. Spec No. Data Version SS-020 Oct 30, 2003 First 1. Scope P: 2/5 This specification covers Rodan Spark Gap RSG-801-BJL.


    Original
    ss-020rsg-801-bjl4r-4198-y794198-y79+6spark gap 801pc 801 sokayaokaya electric industries100cx101 PDF