SINGLE POLE CHANGEOVER Search Results
SINGLE POLE CHANGEOVER Result Highlights (5)
Part | ECAD Model | Manufacturer | Description | Download | Buy |
---|---|---|---|---|---|
TCWA1225G |
![]() |
High Power Switch / SPDT / WCSP14 | Datasheet | ||
TC7USB42MU |
![]() |
Dual SPDT USB switch, SPDT, UQFN10B, -40 to 85 degC | Datasheet | ||
TC7MBL3125CFT |
![]() |
Quad Bus Switch, SPST, TSSOP14, -40 to 85 degC | Datasheet | ||
TC7SB3157DL6X |
![]() |
Single 1-of-2 Multiplexer/Demultiplexer, SPDT, MP6D, -40 to 85 degC | Datasheet | ||
AV-THLIN2RCAM-005 |
![]() |
Amphenol AV-THLIN2RCAM-005 Thin-line Single RCA Coaxial Cable - RCA Male / RCA Male (Coaxial Digital Audio Compatible) 5ft |
SINGLE POLE CHANGEOVER Datasheets Context Search
Catalog Datasheet | Type | Document Tags | |
---|---|---|---|
Contextual Info: DATA SHEET RELAY Relays utilising the ‘B’ Type movement are manufactured with four contact arrangements: i.e. single pole 60 amp, single pole 35 amp bridging make-andbreak, single pole 20 and 30 amp changeover and two-pole 10 amp changeover. The movement is balanced and has a high contact pressure combined with a |
Original |
DSRELB-0805 DSRELB-0305 | |
mccb 60947-2 max zs
Abstract: 60947-2 MAX EARTH LOOP IMPEDANCE hager 3 phase MCB installation drawing hager mcb HD149U MCCB wiring diagram HD148U IEC 60947-2 max zs HN204
|
Original |
0-125A 630ples mccb 60947-2 max zs 60947-2 MAX EARTH LOOP IMPEDANCE hager 3 phase MCB installation drawing hager mcb HD149U MCCB wiring diagram HD148U IEC 60947-2 max zs HN204 | |
mccb 60947-2 max zs
Abstract: 60947-2 MAX EARTH LOOP IMPEDANCE wiring diagram of rccb hager mcb 3 phase MCB installation drawing hager HD149U rcbo circuit diagram HMF280T ADA925U
|
Original |
0-125A 630ples mccb 60947-2 max zs 60947-2 MAX EARTH LOOP IMPEDANCE wiring diagram of rccb hager mcb 3 phase MCB installation drawing hager HD149U rcbo circuit diagram HMF280T ADA925U | |
CB9101-16
Abstract: CB9103
|
OCR Scan |
CB9101-16 CB9102-16 CB9103-16 CB9101-16 CB9102-16 CB9103-16 J392982 r96981 CB9103 | |
X3120
Abstract: din 46244-A2.8-0.5
|
Original |
3120-F. 3120-F5 X3120 din 46244-A2.8-0.5 | |
DIN iso 13715
Abstract: breaker interlock shunt release coil function e-t-a 3120 X3120 DIN 13715
|
Original |
3120-F. 3120-F5 DIN iso 13715 breaker interlock shunt release coil function e-t-a 3120 X3120 DIN 13715 | |
Contextual Info: Thermal Overcurrent Circuit Breaker 3120-F. Description An extremely versatile range of rocker switch/thermal circuit breakers Stype TO CBE to EN 60934 with trip free mechanism offering the choice of single pole, double pole with single pole protection, and double pole with |
Original |
3120-F. 3120-F5 | |
DIN iso 13715
Abstract: electromedical X3120 shunt release coil function 3120-F3 iso 13715
|
Original |
3120-F. 3120-F5 DIN iso 13715 electromedical X3120 shunt release coil function 3120-F3 iso 13715 | |
DIN iso 13715
Abstract: DIN 13715 trip coil X3120 breaker interlock shunt release coil function 3120F
|
Original |
3120-F. 3120-F5 DIN iso 13715 DIN 13715 trip coil X3120 breaker interlock shunt release coil function 3120F | |
VDE 0660 - 107
Abstract: shunt release coil function X3120 bulb h7 3120-F IEC 68-2-11 magnetic relay DIN 40050 Part 9 IEC 529 3120F
|
Original |
3120-F. X3120 VDE 0660 - 107 shunt release coil function bulb h7 3120-F IEC 68-2-11 magnetic relay DIN 40050 Part 9 IEC 529 3120F | |
DIN iso 13715
Abstract: iso 13715 X3120 3120f electromedical shunt release coil function
|
Original |
3120-F. 3120-F5 DIN iso 13715 iso 13715 X3120 3120f electromedical shunt release coil function | |
Contextual Info: Thermal Overcurrent Circuit Breaker 3120-F. Description An extremely versatile range of rocker switch/thermal circuit breakers Stype TO CBE to EN 60934 with trip free mechanism offering the choice of single pole, double pole with single pole protection, and double pole with |
Original |
3120-F. 3120-F5 | |
DIN iso 13715
Abstract: "Rocker Switch" illuminated 60601 X3120 shunt release coil function
|
Original |
3120-F. 3120-F5 DIN iso 13715 "Rocker Switch" illuminated 60601 X3120 shunt release coil function | |
shunt release coil function
Abstract: DIN 6784 tolerances 102158 STANDARD DIN 6784 relay w 107 breaker interlock X3120 DIN IEC 60068-2-11 k
|
Original |
3120-F. 3120-F5 X3120 shunt release coil function DIN 6784 tolerances 102158 STANDARD DIN 6784 relay w 107 breaker interlock DIN IEC 60068-2-11 k | |
|
|||
Marquardt 9050
Abstract: Marquardt Switches MARQUARDT snap on tools for electronic 25e3 switch keymodule automatic plant watering circuit change over switch Single Pole Miniature Slide Switch 25E3
|
Original |
||
changeover switch
Abstract: VDE0860
|
OCR Scan |
119pole changeover switch VDE0860 | |
C175000Contextual Info: 1700 & 1750 Lever Switches 16A 250Vac Single and Double Pole <£b ® ® © KU <©® ®> ® ® 'W Wk@ 16 4 A 250Vac T85 Inrush 36A to EN61058-1 20A 28Vdc UL 20A 250V Non Ind Single pole 16A 250V Non Ind Double pole UL CSA (2 pos types) 250V 1 hp, 125V /h p |
OCR Scan |
250Vac EN61058-1 28Vdc E45221 700HO C1750Hion A0539MO C175000 | |
Contextual Info: SERIES 1299 - SINGLE-POLE POWER TOOL SWITCHES TOGGLE SWITCHES PUSHBUTTON SWITCHES ROCKER SWITCHES TO 6 6 A 250 V AC Single-pole normally open contact with integrated potential-free linear potentiometer Other colors Powerful with up to 6 A at 100 000 mechanical switching cycles |
Original |
||
SM0265
Abstract: SM0265/PD SX0550 SX0790 SX0792 PD3A
|
Original |
SM0259/PD SM0265/PD SM0259) SM0259/PD SX0790 SX0791 SX0792 SM0265 SX0550 SX0790 SX0792 PD3A | |
SX0550
Abstract: SX0780 SX0783 SX0790 SX0792
|
Original |
SX0790 SX0791 SX0792 SX0793 SX0794 SX0790 SX0787 SX0780 SX0550 SX0550 SX0783 SX0792 | |
SX0790
Abstract: SX0792 SX0550 SX0793
|
Original |
SX0790 SX0791 SX0792 SX0793 SX0794 SX0790 SX0792 SX0550 SX0793 | |
817 CN
Abstract: cn170
|
Original |
tappe155 817 CN cn170 | |
RELECO C4-A40
Abstract: RELECO C3-A30 FX 24 VDC C7-A20 FX, RELECO RELECO C3-R20 24VDC RELECO C2-A 20 C5-A30, RELECO RELECO c3 a30 fx 24 v dc C9-A41, RELECO CT2-E20-H C5-M10D
|
Original |
S10BB RELECO C4-A40 RELECO C3-A30 FX 24 VDC C7-A20 FX, RELECO RELECO C3-R20 24VDC RELECO C2-A 20 C5-A30, RELECO RELECO c3 a30 fx 24 v dc C9-A41, RELECO CT2-E20-H C5-M10D | |
Contextual Info: Hermetically sealed cell 83151 5 For further information, contact us. www.crouzet.com 6 www.crouzet.com For further information, contact us. HERMETICALLY SEALED MICROSWITCH ES SINGLE POLE, CHANGEOVER TYPES 83 151 150°C AND DERIVA TIVES PRESENTATION This is the basic comporent for our whole range of standard 1-pole and 2-poIes hermetically-sealed limit switches plus the 3-poIes version (special Umit Switches). |
Original |