SIEMENS HUMIDITY SENSOR Search Results
SIEMENS HUMIDITY SENSOR Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| TCTH022BE | Toshiba Electronic Devices & Storage Corporation | Over Temperature Detection IC / VDD=1.7~5.5V / IPTCO=10μA / IDD=11.3μA / Open-drain type / FLAG signal latch function | Datasheet | ||
| TCTH021BE | Toshiba Electronic Devices & Storage Corporation | Over Temperature Detection IC / VDD=1.7~5.5V / IPTCO=10μA / IDD=11.3μA / Open-drain type | Datasheet | ||
| HDC1008YPAT | Texas Instruments | Low Power, 4% Accuracy Digital Humidity Sensor with Integrated Temperature Sensor 8-DSBGA -40 to 125 |
|
||
| HDC1080DMBR | Texas Instruments | HDC1080 Low Power, High Accuracy Digital Humidity Sensor with Temperature Sensor 6-WSON -40 to 125 |
|
|
|
| HDC1080DMBT | Texas Instruments | HDC1080 Low Power, High Accuracy Digital Humidity Sensor with Temperature Sensor 6-WSON -40 to 125 |
|
|
Documents mentioning SIEMENS HUMIDITY SENSOR
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| 1860p01 | 1 1860P01 860 QFM65.1 Duct sensor for relative humidity and temperature Operating voltage AC 24 V Signal output DC 0…10 V for relative humidity Signal output L&S Ni 1000 (passive) for temperature Measurement accuracy ± 3 % r. h. within the comfort range |
Original | ||||
| qfa66 | 1 1852P020 1852P010 852 QFA66 QFA66 with AQF21.1 QFA66 Room sensor for relative humidity and temperature • Operating voltage AC 24 V Autput signals DC 0…10 V for relative humidity and temperature Very high measuring accuracy throughout the entire measuring range |
Original | ||||
| qfa81 | 1 Room Hygrostats 513 QFA81… for relative humidity QFA81.1 QFA81 On / off hygrostat with microswitch, with humidity sensor, with plastic texture sensing strip (good linearity, wide measuring range), for the control of humidification equipment, for the control of dehumidification equipment, |
Original | ||||
| 1851p010 | 1 1851P010 850 QFA65.1 Room Sensor for relative humidity and temperature Operating voltage AC 24 V Signal output DC 0…10 V for relative humidity Signal output LG-Ni 1000 (passive) for temperature Accuracy of ± 3 % r.h. within comfort range Use In ventilating and air conditioning plants to acquire |
Original | ||||
| hygro | 1 Duct Hygrostats 514 QFM81… for relative humidity QFM81.21 QFM81.2 On / off hygrostat with microswitch, with temperature-compensated humidity sensor for temperature-independent humidity measurements, with stabilized sensing strip (good linearity, very stable even at high humidity, |
Original | ||||
| qfa2060 | 1 1857P01 857 QFA20… QFA2060D Room sensors QFA20… For relative humidity and temperature • Operating voltage AC 24 V or DC 13.5…35 V Signal output DC 0…10 V / 4 … 2 0 m A for relative humidity Signal output DC 0…10 V / 4…20 mA / LG-Ni 1000 or T1 for temperature |
Original | ||||
| qpm2102 | 1 962 QPM2102D QPM2160D, QPM2162D QPM1100, QPM2100, QPM2102 Duct Air Quality Sensors QPM2160, QPM2180 QPM11… QPM21… • maintenance-free CO 2 sensing element (depending on the type) based on optical infrared absorption measurement (NDIR1) • or with VOC 2) sensing element, based on a heated tin dioxide semiconductor |
Original | ||||
| qaa32 | 1 747 Room Temperature Sensor QAA32 NTC resistor sensing element Use In HVAC plants to acquire the room temperature. Functions 1747D01 Ω 9000 7000 5000 The sensor acquires the room temperature by means of its NTC resistor. The resistance value changes according to the ambient |
Original | ||||
| qaz21 | 1 1833P014 848 Cable Temperature Sensors QAZ21.682/101 QAZ21.685/101 for use in refrigeration plant Cable temperature sensor for acquiring the medium temperature in refrigeration plant. Strap-on sensor with 2 cable ties or immersion sensor with a protection |
Original | ||||
| air velocity sensor | 1 1932P01 932 Air velocity sensor QVM62.1 Use This sensor is used to control the air velocity to a constant value, or to balance out pressure fluctuations (supply or extract air control), or to monitor the flow in air ducts. It primarily is used for modulating fan control in primary plants to set the basic volume |
Original | ||||
| 1801p01 | 1 1801P01 801 Strap-on temperature sensor QAD22 Strap-on sensor for acquiring the temperature of pipework. Use Acquisition of temperature of pipework for • controlling or limiting the flow temperature • limiting the return temperature • controlling the d.h.w. temperature |
Original | ||||
| qam22 | 1 Mounting flange 1771P02 1771P034 1771P01 771 QAM22 QAM22.2, QAM22.6 Duct Temperature Sensors QAM22… Serie B Sensors für acquiring the temperature in air ducts. Use The QAM22… duct temperature sensor is for use in ventilation and air conditioning plants for the following purposes: |
Original | ||||
| pressure sensor | 1 921 Differential pressure sensor QBE64-DP4 for neutral and mildly corrosive liquids and gases Differential pressure sensor, suitable for gases or liquids, for the measurement of positive or negative pressures and pressure differentials in HVAC systems. • Measuring system based on ceramic lever technology |
Original | ||||
| 1811p01 | 1 1811P01 811 QAC… Outside Sensors Passive sensors for acquiring the outside temperature and – to a lesser degree – solar radiation, the wind effect and the temperature of the wall. Use The QAC… outside sensors are for use in heating, ventilation and air conditioning |
Original | ||||
|
|
||||||
| fr-t1k | 1 735 FR-T1K Room temperature sensor Compact room sensor for measurement of the air temperature in conjunction with HVAC systems • T1 measuring element Suitable for wall-mounting Ideal where space is limited Discreet appearance FR-T1K Technical data |
Original | ||||
| 1721p020 | 1… 1721P020 1721P010 721 QAA24 QAA25…QAA27 Room Temperature Sensors QAA24…27 with and without setpoint adjuster Use In heating, ventilating and air conditioning plants, especially where a high level of comfort is required. Major field of application: |
Original | ||||
| 1791p01 | 1 791 1791P01… Immersion temperature sensors QAE22… Immersion sensor for acquiring the water temperature in pipes or tanks. Use Acquisition of the water temperature for • controlling or limiting the flow temperature • limiting the return temperature |
Original | ||||
| qpa84 | 1 Indoor Air Quality Controller 571 QPA84 With integrated VOC 1) ) sensor, operating voltage AC 230 V, two-position output (non-potential-free relay contact) 1) VOC = Volatile Organic Compounds Use In ventilation plant to optimize the indoor air quality and the consumption of energy by |
Original | ||||
| bts114a | SIEMENS TEMPFET® BTS114A Features • N channel • Enhancement mode • Temperature sensor with thyristor characteristic • The drain pin is electrically shorted to the tab Pin 1 2 3 G D S Type v DS /d ^DS<on) Package Ordering Code BTS 114A 50 V 17 A 0.10 n |
OCR Scan | ||||
| bts131 | SIEMENS TEMPFET® BTS131 Features • N channel Logic level Enhancement mode Temperature sensor with thyristor characteristic The drain pin is electrically shorted to the tab 1 Pin 1 2 3 G D S 2 Refer to circuit design hints (see chapter Technical Information) |
OCR Scan | ||||
| SIEMENS Smart Highside Power Switch TEMPFET® | SIEMENS Smart Highside Power Switch TEMPFET® Features • P channel Enhancement mode Temperature sensor with thyristor characteristic The drain pin is electrically shorted to the tab Type Vos h BTS 100 -5 0 V -8 A ^DS<on) 0.3 £2 Package Ordering Code |