Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    SIEMENS BUILDING TECHNOLOGIES Search Results

    SIEMENS BUILDING TECHNOLOGIES Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    CS-SATDRIVEX2-002
    Amphenol Cables on Demand Amphenol CS-SATDRIVEX2-002 Serial ATA Extension Cable - SATA II Drive Extension Cable with Power (6.0 Gbps) 2m PDF
    CS-SATDRIVEX2-000.5
    Amphenol Cables on Demand Amphenol CS-SATDRIVEX2-000.5 Serial ATA Extension Cable - SATA II Drive Extension Cable with Power (6.0 Gbps) 0.5m PDF
    CS-SATDRIVEX2-001
    Amphenol Cables on Demand Amphenol CS-SATDRIVEX2-001 Serial ATA Extension Cable - SATA II Drive Extension Cable with Power (6.0 Gbps) 1m PDF
    CS-SASDDP8282-000.5
    Amphenol Cables on Demand Amphenol CS-SASDDP8282-000.5 29 position SAS to SATA Drive Connector Dual Data Lanes Cable 0.5m PDF
    CS-SASDDP8282-001
    Amphenol Cables on Demand Amphenol CS-SASDDP8282-001 29 position SAS to SATA Drive Connector Dual Data Lanes Cable 1m PDF

    SIEMENS BUILDING TECHNOLOGIES Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    enthalpy

    Contextual Info: s Synco 700 Switching and monitoring device RMS705B incl. extension modules RMZ785, RMZ787und RMZ788 Basic documentation CE1P3124en 01.04.2010 Building Technologies Siemens Switzerland Ltd Building Technologies Division International Headquarters Gubelstrasse 22


    Original
    RMS705B RMZ785, RMZ787und RMZ788 CE1P3124en CH-6301 enthalpy PDF

    peb4266t

    Abstract: PEB 4266T 4266V PEB3265F 3264H PEB 4264t v1.2 3265H PEB 3264 v1.4 PEB3265H 4264T
    Contextual Info: D u S L I C F A M I LY OV E R V I E W INFINEON TECHNOLOGIES AG’S SALES OFFICES WORLDWIDE – P A R T LY R E P R E S E N T E D B Y S I E M E N S A G Features SLICOFI-2 Number of voice channels SLICOFI-2S SLICOFI-2S2 2 2 2 DTMF detection Yes No No Line echo cancellation up to 8 ms


    Original
    20B/3/31 B159-H7909-X-X-7600 peb4266t PEB 4266T 4266V PEB3265F 3264H PEB 4264t v1.2 3265H PEB 3264 v1.4 PEB3265H 4264T PDF

    TDA 16846 P

    Abstract: tda 2750 tda 4605 application note TDA 1031 transistor Siemens 14 S S 92 K2k transistor IC tda 16846 TDA 1060 f TDA 16846 TDA4605
    Contextual Info: Version 1.0 , March 2000 Application Note AN-SMPS-CoolMOS-1 SMPS with CoolMOS and TDA 16846x Author: Peter Preller Published by Infineon Technologies AG http://www.infineon.com Power Conversion Titel: Infineon Logo 4c.eps Erstellt von: Adobe Illustrator(R) 8.0


    Original
    16846x PostScript-Druc90 Room14J1 Room1101 TDA 16846 P tda 2750 tda 4605 application note TDA 1031 transistor Siemens 14 S S 92 K2k transistor IC tda 16846 TDA 1060 f TDA 16846 TDA4605 PDF

    Siemens Ni1000 temperature sensor

    Abstract: n531 QAC22 N9292 LG-Ni1000 QFM3100 triac BT 317 DATASHEET
    Contextual Info: System Catalog 2014 The information in this document contains general descriptions of technical options available, which do not always have to be present in individual cases. The required features should therefore be specified in each individual case at the time of closing the contract.


    Original
    PDF

    CA2N3804

    Contextual Info: s 3 878 RXL RXL24.1 Room controller Communicating controller for chilled ceiling and radiator applications CC-02 The RXL24.1 room controller is used for temperature control in individual rooms. • For chilled ceiling and radiator systems  PI control  Proprietary bus communication


    Original
    RXL24 CC-02 CM2N3878en 3873M14 3877M15 CA2N3804 PDF

    QXA2602

    Abstract: CM1Y9777 TRIAC ACS 12 QXA2604 cm1y9775 X2M ST
    Contextual Info: s Room thermostats with KNX communications 3 191 RDG100KN RDG160KN – For fan coil unit applications – For universal applications – For use with compressor in DX type equipment • • • • • • • • • • • • • • • • KNX bus communication S-mode and LTE mode


    Original
    RDG100KN RDG160KN RDG100KN, RDG160KN CE1N3191en QXA2602 CM1Y9777 TRIAC ACS 12 QXA2604 cm1y9775 X2M ST PDF

    microcontroller infineon

    Abstract: infineon tricore
    Contextual Info: FOR IMMEDIATE RELEASE CONTACT US: Chris Goodhart 408 501-6389 chris.goodhart@infineon.com CONTACT INTERNATIONAL: Katja Schlendorf +49 (89) 234-28480 katja.schlendorf@infineon.com Infineon Technologies Opens New Development Center in Bristol, England Expansion of Global Design Network Drives Forward Logic Initiative


    Original
    PDF

    BT 4830

    Abstract: Siemens wireless temperature sensor BT+4830
    Contextual Info: 3 RDH10RF 070 RCR10/433 Wireless room temperature controller with LCD RDH10RF/SET Non-programmable, for heating or cooling systems • · · · · Operating modes: Automatic, Comfort, Energy Saving, and Frost Protection LCD-Display 50 x 45 W x H RDH10RF transmitter, battery-powered


    Original
    RDH10RF RCR10/433 RDH10RF/SET RDH10RF RCR10/433 CE1N3070en BT 4830 Siemens wireless temperature sensor BT+4830 PDF

    STR 6754

    Abstract: str 6754 circuit PMB 8760 bluemoon pmb STR W 6754 B165H AN 6754 72 dect pmb dect pmb PMB6752
    Contextual Info: THE RIGHT TOOL FOR THE JOB BlueMoon – three Solutions for Bluetooth™ Applications www.infineon.com/bluetooth Never stop thinking. INFINEON TECHNOLOGIES AND BLUETOOTH™ D r a w i n g o n a l o n g , successful history in the digital cordless arena, Infineon Technologies is committed to giving its customers early access to


    Original
    B165-H-7072-G7-x-7600 DK-2750 STR 6754 str 6754 circuit PMB 8760 bluemoon pmb STR W 6754 B165H AN 6754 72 dect pmb dect pmb PMB6752 PDF

    TDA16822

    Abstract: transformer calculation flycal excel flycal AN-SMPS-1683X-1 TDA 16822 TDA16831 smps 10w 12V smps 10w 5V SMPS CIRCUIT DIAGRAM
    Contextual Info: Version 1.0 , July 2000 Application Note AN-SMPS - 16822-1 CoolSET Application Note Supplement Authors: Harald Zöllinger Rainer Kling Published by Infineon Technologies AG http://www.infineon.com Power Conversion N e v e r s t o p t h i n k i n g CoolSET Application Note Supplement


    Original
    CAL90 Room14J1 Room1101 TDA16822 transformer calculation flycal excel flycal AN-SMPS-1683X-1 TDA 16822 TDA16831 smps 10w 12V smps 10w 5V SMPS CIRCUIT DIAGRAM PDF

    QXA2602

    Abstract: SY-HS-230 HUMIDITY SENSOR QXA2603 siemens relay
    Contextual Info: 3 SIEMENS QXA2601/QXA2603 QXA2602/QXA2604 Condensation Monitor • • • • • • CB1N3302en_01 2014-04-24 302 QXA2601 QXA2602 QXA2603 QXA2604 Operating voltage AC / DC 24 V or AC 230 V Potential free changeover contact AC/ DC 1…30 V or AC 230 V Simple and fast mounting


    Original
    QXA2601/QXA2603 QXA2602/QXA2604 CB1N3302en QXA2601 QXA2602 QXA2603 QXA2604 CE1T3302xx QXA2602 SY-HS-230 HUMIDITY SENSOR QXA2603 siemens relay PDF

    CA110300

    Contextual Info: s 3 856 Desigo RXC Room controller RXC39.5 Communicating room controller for fan-coil applications The RXC39.5 room controller is used for temperature control in individual rooms. • For fan-coil systems with ECM fan · PI / PID control depending on application


    Original
    RXC39 RXT10 CM2N3856en 3876M01 3876M02 CA110300 PDF

    QBE620-P10

    Abstract: AQB51 QBE620-P16 Landis QBE620-P40 AQB22 QBE620-P QBE620-P25 QBE620-P5 QBE620-P1
    Contextual Info: 1 904 Pressure sensor for liquid and gaseous media QBE620-P. Pressure sensor for the measurement of positive pressure in HVAC applications. • Piezo-resistive system of measurement • DC 0 .10 V output signal • Complete sensor cast in synthetic resin


    Original
    QBE620-P. the/336 EN50081-1, EN50081-2, EN50082-2 CA1N1904E AQB22 QBE620-P10 AQB51 QBE620-P16 Landis QBE620-P40 QBE620-P QBE620-P25 QBE620-P5 QBE620-P1 PDF

    QBE621-P10U

    Abstract: HVAC QBE621-P25U Siemens sensors QBE621-P60U Sealing compound time temp AQB22 qbe*21. Pressure Sensor siemens hvac
    Contextual Info: 1 1905P02 905 Pressure sensors QBE621-P.U for refrigerants Pressure sensor for the measurement of positive positive and negative pressure in HVAC applications with low temperature liquids or gases. • Piezo-resistive system of measurement • DC 0.10 V output signal


    Original
    1905P02 QBE621-P. CA1N1905E AQB22 QBE621-P10U HVAC QBE621-P25U Siemens sensors QBE621-P60U Sealing compound time temp qbe*21. Pressure Sensor siemens hvac PDF

    polygyr

    Abstract: QBE61 qbe61.2 Landis PN40 water differential pressure sensor chilled water system landis and staefa Differential Pressure siemens siemens humidity sensor
    Contextual Info: 1 Differential Pressure Sensor 915 QBE61.2-dp0,5 This sensor delivering an active measuring signal of DC 0.10 V and works on a AC 24 V operating voltage. Measuring ranges between 0 and 0.5 bar differential pressure. Application Sensing of differential pressure in heating, ventilating and air conditioning plants.


    Original
    QBE61 1915G01 CM1N1915E 1901M02E 1915M01 CM1N3463E polygyr qbe61.2 Landis PN40 water differential pressure sensor chilled water system landis and staefa Differential Pressure siemens siemens humidity sensor PDF

    siemens air pressure sensors

    Abstract: QBE63-DP1 QBE63-DP01 landis and staefa Landis staefa Differential Pressure siemens QBE63-DP05 dp01 QBE63-DP02
    Contextual Info: 1 920 Differential pressure sensor QBE63-DP. for neutral and mildly corrosive liquids and gases Differential pressure sensor, suitable for gases and liquids, for the measurement of positive and negative pressures and pressure differentials in HVAC systems.


    Original
    QBE63-DP. EG89/336 EN50081-1, EN50081-2, EN50082-2 CA1N1920E siemens air pressure sensors QBE63-DP1 QBE63-DP01 landis and staefa Landis staefa Differential Pressure siemens QBE63-DP05 dp01 QBE63-DP02 PDF

    CA2A3810

    Abstract: CA2N3804 RXT10 CM110669
    Contextual Info: 3 s 840 Desigo RXC Room controller, basic module RXC30.1/ RXC30.5 for chilled ceiling/radiator control and for control of lighting, with LONMARK -compatible bus communications The RXC30 controller is used for the control of temperature and lighting in


    Original
    RXC30 STP73 RXC30 CA2N3840en 3840M02 3840M01 CA2A3810 CA2N3804 RXT10 CM110669 PDF

    AlMgSi1

    Abstract: Differential Pressure siemens QBE64-dp4 staefa Landis Landis Staefa QBE siemens air pressure sensors AQB51 EN50081 QBE64
    Contextual Info: 1 921 Differential pressure sensor QBE64-DP4 for neutral and mildly corrosive liquids and gases Differential pressure sensor, suitable for gases or liquids, for the measurement of positive or negative pressures and pressure differentials in HVAC systems. • Measuring system based on ceramic lever technology


    Original
    QBE64-DP4 QBE64-DP4 EN50082-2 CA1N1921E AlMgSi1 Differential Pressure siemens staefa Landis Landis Staefa QBE siemens air pressure sensors AQB51 EN50081 QBE64 PDF

    Siemens QFM65

    Abstract: QFM65 temperature sensor Landis Ni 1000 staefa qfm65 Siemens duct temperature controller staefa t1 sensor QFM65-1 siemens hvac qfm65 STAEFA Building Management System
    Contextual Info: 1 1860P01 860 QFM65.1 Duct sensor for relative humidity and temperature Operating voltage AC 24 V Signal output DC 0.10 V for relative humidity Signal output L&S Ni 1000 passive for temperature Measurement accuracy ± 3 % r. h. within the comfort range


    Original
    1860P01 QFM65 1860M01 1860M02 CM1N1860en Siemens QFM65 temperature sensor Landis Ni 1000 staefa qfm65 Siemens duct temperature controller staefa t1 sensor QFM65-1 siemens hvac qfm65 STAEFA Building Management System PDF

    siemens QBM65-1U

    Abstract: siemens air pressure sensors QBM65-1U QBM65-5 qbm65-1 QBM65-25 Differential Pressure siemens Siemens QBM65-1 AQB21 Siemens duct temperature sensor
    Contextual Info: 1 QBM65-., QBM65.2-. 1916P03 1916P01 916 QBM65.1-. Differential pressure sensors QBM65. for air and nonaggressive gases • With choice of pressure-linear or extracting-the-root characteristic with adjustable pressure measuring range • Operating voltage AC 24 V or DC 13.5. 33 V


    Original
    QBM65-. QBM65 1916P03 1916P01 QBM65. CA1N1916E 1916G01 siemens QBM65-1U siemens air pressure sensors QBM65-1U QBM65-5 qbm65-1 QBM65-25 Differential Pressure siemens Siemens QBM65-1 AQB21 Siemens duct temperature sensor PDF

    qbe*61.1

    Abstract: QBE61 landis qbe61.1-p20 polygyr QBE61.1 pressure sensor landis qbe61,1 p20 staefa Landis siemens r134a QBE61 p2
    Contextual Info: 1 Pressure Detectors 901 QBE61.1. Active pressure detector delivering a DC 0.10 V measuring signal and operating on AC 24 V. There are five different versions available, with measuring ranges between 0 and 40 bar. Application Measuring and sensing of overpressure in heating, ventilating and air conditioning


    Original
    QBE61 CM1N1901E 1901G01 1901M03E 1901M02E 1901M01 CM1N3461E qbe*61.1 landis qbe61.1-p20 polygyr QBE61.1 pressure sensor landis qbe61,1 p20 staefa Landis siemens r134a QBE61 p2 PDF

    QFA66

    Abstract: 2m246 Siemens PT1000 temperature sensor AQF21 Siemens PT1000 PT1000 temperature sensor circuit PT1000 siemens F HVAC light sensor siemens Siemens temperature sensor
    Contextual Info: 1 1852P020 1852P010 852 QFA66 QFA66 with AQF21.1 QFA66 Room sensor for relative humidity and temperature • • • • Operating voltage AC 24 V Autput signals DC 0.10 V for relative humidity and temperature Very high measuring accuracy throughout the entire measuring range


    Original
    1852P020 1852P010 QFA66 QFA66 AQF21 CM1N1852E 2m246 Siemens PT1000 temperature sensor Siemens PT1000 PT1000 temperature sensor circuit PT1000 siemens F HVAC light sensor siemens Siemens temperature sensor PDF

    qfm64

    Abstract: RWF61 polygyr polygyr RWF61 rwf61 siemens Siemens duct temperature controller polygyr 3401 rwf61.20 enthalpy Pt 1000 sensor siemens
    Contextual Info: 1 899 1899P01 . . . . . . . . . Transducer for absolute Humidity and Enthalpy AQF61.1 Microprocessor-based converter to calculate absolute humidity, enthalpy and enthalpy differential. Application • In ventilating and air conditioning plants. • To measure, regulate, control and display absolute humidity, enthalpy or enthalpy


    Original
    1899P01 AQF61 ARG81 QFM64 RWF61. qfm64 RWF61 polygyr polygyr RWF61 rwf61 siemens Siemens duct temperature controller polygyr 3401 rwf61.20 enthalpy Pt 1000 sensor siemens PDF

    N1589

    Abstract: AQB21 siemens air pressure sensors QBM65-3 calibration certificate QBM65-10 QBM65-25 staefa duct sensors DIFFERENTIAL "Pressure Sensor" QBM75-1U/C
    Contextual Info: 1 1919P03 1919P01 919 QBM65./C, QBM75-1U/C QBM75.1-1/C QBM65./C QBM75./C Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate • Highly accurate measurements with calibration certificate • Simple and quick to install


    Original
    1919P03 1919P01 QBM65. QBM75-1U/C QBM75 QBM75. CA1N1919E N1589 AQB21 siemens air pressure sensors QBM65-3 calibration certificate QBM65-10 QBM65-25 staefa duct sensors DIFFERENTIAL "Pressure Sensor" QBM75-1U/C PDF