Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    SHIELD WINDING Search Results

    SHIELD WINDING Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    MP-6ARJ45SNNB-030
    Amphenol Cables on Demand Amphenol MP-6ARJ45SNNB-030 CAT6A FTP Shielded Patch Cable (650-MHz) with Snagless CAT-6A Shielded RJ45 Connectors (10GbE Optimized) - Blue 30ft PDF
    MP-6ARJ45SNNG-030
    Amphenol Cables on Demand Amphenol MP-6ARJ45SNNG-030 CAT6A FTP Shielded Patch Cable (650-MHz) with Snagless CAT-6A Shielded RJ45 Connectors (10GbE Optimized) - Green 30ft PDF
    MP-6ARJ45SNNK-030
    Amphenol Cables on Demand Amphenol MP-6ARJ45SNNK-030 CAT6A FTP Shielded Patch Cable (650-MHz) with Snagless CAT-6A Shielded RJ45 Connectors (10GbE Optimized) - Black 30ft PDF
    MP-6ARJ45SNNR-030
    Amphenol Cables on Demand Amphenol MP-6ARJ45SNNR-030 CAT6A FTP Shielded Patch Cable (650-MHz) with Snagless CAT-6A Shielded RJ45 Connectors (10GbE Optimized) - Red 30ft PDF
    MP-6ARJ45SNNW-030
    Amphenol Cables on Demand Amphenol MP-6ARJ45SNNW-030 CAT6A FTP Shielded Patch Cable (650-MHz) with Snagless CAT-6A Shielded RJ45 Connectors (10GbE Optimized) - White 30ft PDF

    SHIELD WINDING Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    th12a

    Abstract: 61008-1 pe-61001 PE-8270 PE-61015 PE-8271 PE-8272 PE-4290X PE-61007 PE-61017
    Contextual Info: GENERAL PURPOSE TRANSFORMERS 2 Watt Pulse, Electrostatically Shielded, and 500 mW Pulse Transformers Mechanicals TH1 to TH5 TH2/TH4: 2 WINDING WITH SHIELD OR 3 WINDING TH1: 2 WINDING TH3/TH5: 2 WINDING WITH CT AND SHIELD OR 3 WINDING WITH SHIELD .100 TYP 2,54


    Original
    pe-4290xprinted12220th12a61008-1+7pe-61001pe-8270pe-61015pe-8271pe-8272pe-61007pe-61017 PDF

    Contextual Info: PFC Boost Inductor EPC3245-XX ELECTRONICS INC. • Used as Power Factor Correction PFC Boost Inductor • Isolation Between Shield and Winding : 4.5K Vrms • All parts have Faraday Shield (except Toroid) • Isolation Between Winding : 1500 Vrms • UL 94V-0 Recognized Components


    Original
    epc3245-xxepc3245-1epc3245-2epc3245-3+6epc3245-4epc3245-5epc3245-6epc3245-7epc3245-8epc3245-9 PDF

    FERRITE TOROID

    Abstract: EPC3245-1 EPC3245-2 EPC3245-3 EPC3245-XX EPC3245-4
    Contextual Info: PFC Boost Inductor ELECTRONICS INC. EPC3245-XX • Used as Power Factor Correction PFC Boost Inductor • Isolation Between Shield and Winding : 4.5K Vrms • All parts have Faraday Shield (except Toroid) • Isolation Between Winding : 1500 Vrms • UL 94V-0 Recognized Components


    Original
    epc3245-xxepc3245-1epc3245-2epc3245-3+7epc3245-4epc3245-5epc3245-6epc3245-7epc3245-8epc3245-9ferrite toroid PDF

    EPC3246-XX

    Abstract: PFC Boost FERRITE TOROID EPC3246-1 EPC3246-2 EPC3246-3 EPC3246-15
    Contextual Info: PFC Boost Inductor ELECTRONICS INC. EPC3246-XX • Used as PFC Boost Inductor with Auxiliary Winding • Isolation Between Shield and Winding : 4.5K Vrms • All parts have Faraday Shield (except Toroid) • Isolation Between Winding : 1500 Vrms • UL 94V-0 Recognized Components


    Original
    epc3246-xxepc3246-1epc3246-2epc3246-3+9epc3246-4epc3246-5epc3246-6epc3246-7epc3246-8epc3246-9pfc boostferrite toroidepc3246-15 PDF

    Contextual Info: PFC Boost Inductor ELECTRONICS INC. EPC3245-XX • Used as Power Factor Correction PFC Boost Inductor • Isolation Between Shield and Winding : 4.5K Vrms • All parts have Faraday Shield (except Toroid) • Isolation Between Winding : 1500 Vrms • UL 94V-0 Recognized Components


    Original
    epc3245-xxepc3245-1epc3245-2epc3245-3+6epc3245-4epc3245-5epc3245-6epc3245-7epc3245-8epc3245-9 PDF

    Contextual Info: Industry standard full capacity taps Wound core construction for lower losses and quiet operation Heavy gauge steel ULType 2 enclosures, UL-3R Listed with weather shield accessory Faraday shield eliminates noise and voltage spikes Vibration isolation pads


    OCR Scan
    PDF

    Contextual Info: SECTION IV_ DRIVE ISOLATION TRANSFORMERS Drive Isolation Transformers Features • U L Type 3 R Enclosures with Weather Shield on Ventilated Units above 20 KVA . Type 2 Enclosure without weather shield. UL listed and CSA certified. 7.5 —


    OCR Scan
    PDF

    Contextual Info: Industry standard full capacity taps Wound core construction for lower losses and quiet operation Heavy gauge steel ULType 2 enclosures, UL-3R Listed with weather shield accessory ,- i ^ Faraday shield eliminates noise and voltage spikes Vibration isolation pads


    OCR Scan
    PDF

    23V366

    Abstract: Thordarson 23V367
    Contextual Info: THORDADSON POWER TRANSFORMERS STEP UP + STEP DOWN + 115 TO 115 VOLTS ISOLATION TRANSFORMERS 115 Volts TO 115 Volts, 50 - 60 Hertz - Isolation & Electrostatic Shield 3 Conductor Input Line Cord & Output Cord with Plug Case & Electrostatic Shield are Connected to Ground


    Original
    23v36423v36523v36623v367+323v36823v548thordarson 23v367 PDF

    Contextual Info: General Description Features • UL Type 3R Enclosure with Weather Shield. Type 2 enclosure without Weather Shield. • UL Listed and CSA Certified. • Shielded for cleaner power. • UL component recognized 220° C insulation system. • 115°C or80°C riseby


    OCR Scan
    me-2-53313-1s PDF

    Contextual Info: G eneral Description Fea ures • 111 Type 3R Enclosure with W eather Shield. Type 2 enclosure without Weather Shield. * Units through 225 KVA are terminated in copper bus. 300 KVA and above are terminated in aluminum bus. • UI. Listed and CSA Certified.


    OCR Scan
    PDF

    Contextual Info: SECTIO N I Drive Isolation Transformers Features • UL Type 3R Enclosures with Weather Shield. Type 2 Enclosure without weather shield. UL listed and CSA certified. • 3-Phase 60 Hertz. • 180° C and 220° C insulation systems. • Encapsulated and ventilated designs.


    OCR Scan
    PDF

    SPW-105

    Abstract: SPW-051 SPW-102 SPW-104 SPW-159 SPW-060 SPW-055 SPW-304 SPW-053 SPW-106
    Contextual Info: ndustry Standard/U.S. Domestic Series-Low •iOfth ChaoeS ws Low Profile - Low Price! M A Superior Design Three flange bobbin design. No electrostatic shield required. Anchor, insulating and crossover tapes. Two distinct, separate windings for each primary


    OCR Scan
    10vctspw-105spw-051spw-102+7spw-104spw-159spw-060spw-055spw-304spw-053spw-106 PDF

    tranformer

    Abstract: 5564 TEW5564
    Contextual Info: ISDN TEW5564 Isolation/Bridging Tranformer TEW5364 is specifically designed to be used as an isolation/bridging transformer in test setups for testing Longitudinal Balance and Return Loss in Primary Rate and Basic Rate Circuits. Features: • Shield between windings.


    Original
    tew5564tew5364tranformer5564 PDF

    MTT-50

    Contextual Info: TDK Power Transformers, Power Inductors Multilayer chip transformers POWER TRANSFORMERS, MTT5050 SERIES TDK Multilayer Chip Transformers have a magnetic shield type and of totally monolithic structure. Magnetic material processing and multilayer tech­ nology eliminate the need for wire winding.


    OCR Scan
    mtt5050270mgmtt-50 PDF

    Pulse Transformer VAC

    Abstract: VAC PULSE TRANSFORMER 2779D 2741L2
    Contextual Info: HIGH FREQUENCY MAGNETICS Specialty Surface Mount Shielded Transformer • Operates as high frequency pulse transformer in telecom switching systems at various signaling rates • Interwinding Electrostatic Shield provides low capacitance and high EMI suppression


    Original
    tm001082741l22779dt1-18+2pulse transformer vacvac pulse transformer PDF

    transformer 230V 16V 350mA

    Contextual Info: LOW VOLTAGE P.C. BOARD MOUNT LOW PROFILE 229 SERIES Key Features: - Low profile mounting, dual-split bobbin design - Low primary to secondary coupling, balanced windings, no electrostatic shield required and low EMF radiation due to semi-toroidal design - Universal dual primary 115/230V - 50/60 Hz.


    Original
    115/230vcom/229229e10229a10+6229b10229c10229d10229e12229a12transformer 230v 16v 350ma PDF

    2771M

    Abstract: S553-6500-84 CT 2048 T192
    Contextual Info: HIGH FREQUENCY MAGNETICS T1/E1 Surface Mount Shielded Hardened Transformers • Operates at the rate of 1.544 Mb/s and the E1 rate of 2.048 Mb/s • Interwinding Electrostatic Shield provides low capacitance and high EMI suppression 2771K and S553-6500-84: Winding 4-1 is


    Original
    tm001412771ks553-6500-842771m+3t1-92ct 2048t192 PDF

    Pulse Transformer VAC

    Contextual Info: HIGH FREQUENCY MAGNETICS Specialty Surface Mount Shielded Transformer • Operates as high frequency pulse transformer in telecom switching systems at various signaling rates • Interwinding Electrostatic Shield provides low capacitance and high EMI suppression


    Original
    tm001082741l22779dt1-18+1pulse transformer vac PDF

    transformer 230V to 12V 500mA

    Contextual Info: LOW VOLTAGE P.C. BOARD MOUNT LOW PROFILE 229 SERIES Key Features: - Low proile mounting, dual-split bobbin design - Low primary to secondary coupling, balanced windings, no electrostatic shield required and low EMF radiation due to semi-toroidal design - Universal dual primary 115/230V - 50/60 Hz.


    Original
    115/230vcom/229229e10229a10+6229b10229c10229d10229e12229a12transformer 230v to 12v 500ma PDF

    2741L2

    Abstract: 2779D TM001
    Contextual Info: HIGH FREQUENCY MAGNETICS Specialty Through Hole Shielded Transformer • Operates as a high frequency pulse transformer in telecom switching systems at various signaling rates • Interwinding Electrostatic Shield provides low capacitance and high EMI suppression


    Original
    tm001032779d2741l2tm001 PDF

    optocoupler PC817D

    Abstract: PC817D PI-3902-070104 LNK353P PI-38 LNK353 TOPSWITCH battery charger 10BQ060 Power Integrations PI Expert BZX79B5V1
    Contextual Info: Design Idea DI-78 LinkSwitch-HF Low Cost 1.6 W CV/CC Charger/Adapter Application Device Power Output Input Voltage Output Voltage Topology Charger/Adapter LNK353 1.6 W 85-265 VAC 5.2 V Flyback Design Highlights • • through the use of transformer shield windings, a snubber R4


    Original
    di-78lnk353en55coveredoptocoupler pc817d+8pc817dpi-3902-070104lnk353ppi-38topswitch battery charger10bq060power integrations pi expertbzx79b5v1 PDF

    Contextual Info: Split Bobbin PC Board Transformers IfH transform er The use of a Split Bobbin allows winding to be nonconcentric side-by-side , consequently high isolation is achieved at low cost. • Eietter insulation — 2500 VRMS hipot is standard. • Lower capacitance — no need for electro-static shield.


    OCR Scan
    ih-120dh-10dh-12dh-16+6dh-20dh-24dh-32dh-40dh-48dh-80 PDF

    1165

    Abstract: T-1165 F-42510-EC switching transformer winding pc-b2510 f42510-ec PCB2510 T1165 EC bobbin transformer winding datasheet
    Contextual Info: 100 kHz Switching Transformer SCHEMATIC DIAGRAM Order of Windings P1 Tape Shield Tape S1+S2 Tape C1 Tape P1 = 45 TURNS # 28 S1 = 19 TURNS 2 x # 27 S2 = 11 TURNS # 32 C1 = 9 TURNS # 32 P1 = Primary Winding S1 = Secondary Winding S2 = Secondary Winding C1 = Control Winding


    Original
    f-42510-ecpcb2510t-11651165+6switching transformer windingpc-b2510f42510-ect1165ec bobbintransformer winding datasheet PDF