SENSORTECHNICS FLOW Search Results
SENSORTECHNICS FLOW Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| UE36C1620005D6A | Amphenol Communications Solutions | 1x1 QSFP-DD cage with 21.5mm high fin pin style heat sink, front to back air flow | |||
| UE36C1650005A3A | Amphenol Communications Solutions | 1x1 QSFP-DD cage with 6.5mm height fin pin style heat sink, front to back air flow | |||
| UE36-C26200-05C3A | Amphenol Communications Solutions | 1x2 QSFP-DD cage with SAN height fin pin style heat sink, side to side air flow | |||
| UE36C162000511A | Amphenol Communications Solutions | 1x1 QSFP-DD cage with 10.4mm height fin pin style heat sink, front to back air flow | |||
| SN65LVDS047DR | Texas Instruments | Quad LVDS Driver with Flow-Through Pinout 16-SOIC -40 to 85 |
|
|
Documents mentioning SENSORTECHNICS FLOW
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| flow sensors | FBO Series Mass flow sensors for gases FEATURES · Ranges 0…±30 to 0…±1000 or -600…1000 sccm1 · Bidirectional sensing · Actual mass flow sensing · Sensortechnics PRO services MEDIA COMPATIBILITY To be used with dry gases only The FBO series is NOT designed for |
Original | ||||
| flow sensors | FMO Series Mass flow sensors for gases FEATURES · Ranges 0…±25 and 0…±1000 sccm1 · Bidirectional sensing · Actual mass flow sensing · Ceramic flow tube · Manifold mount/O-ring sealed · Sensortechnics PRO services MEDIA COMPATIBILITY To be used with dry gases only. |
Original | ||||
| flow sensors | FDU Series Mass flow sensors for gases FEATURES · Ranges 0…±200 sccm1 or 0…±2 "H2O (0…±5 mbar) · Bidirectional sensing · Actual mass flow sensing · Low differential pressure sensing · Sensortechnics PRO services MEDIA COMPATIBILITY To be used with dry gases only |
Original | ||||
| flow sensors | FBA Series Mass flow sensors for gases FEATURES · Ranges 0…30 to 0…±1000 sccm1 · 1…5 V or 1…3.75 V output · Actual mass flow sensing · Sensortechnics PRO services MEDIA COMPATIBILITY To be used with dry gases only The FBA series is NOT designed for liquid |
Original | ||||
| RPU Series Basic pressure sensors FEATURES · 0…35 | RPU Series Basic pressure sensors FEATURES · 0…35 mbar to 0…16 bar and 0…0.5 to 0…250 psi gage or differential · High impedance bridge · Miniature package · Different pinning configurations · Usable for wet/wet applications8 · Sensortechnics PRO services |
Original | ||||
| flow sensor | FMA Series Mass flow sensors for gases FEATURES · Ranges 0…1000 sccm1 and 0…6 slpm2 · Actual mass flow sensing · 1…5 V output · Manifold mount/O-ring sealed · Sensortechnics PRO services MEDIA COMPATIBILITY To be used with dry gases only The FMA series is NOT designed for liquid |
Original | ||||
| flow sensor | FHA Series Mass flow sensors for gases FEATURES · Ranges 0…200 slpm1 · Actual mass flow sensing · 1…5 V output · Sensortechnics PRO services MEDIA COMPATIBILITY To be used with dry gases only The FHA series is NOT designed for liquid flow and will be damaged by liquid flow through |
Original | ||||
| soleniod | Series 9 and 99 Pulse Valves High-performance media resistant soleniod valves FEATURES · Flange mount, axial flow, 2-way normally closed valves · Operates as fast as 2 ms (with IOTA ONE valve controller as fast as 160 µs) · Delivers repeatable pulses and |
Original | ||||
| VSO-HP High performance pressure controllers | VSO-HP High performance pressure controllers FEATURES · Stable pressure control with minimal thermal drift · Rapid depressurisation · High accuracy; high repeatability · Low power consumption · Optional 5 V supply output · Configurable for pressure or flow control |
Original | ||||
| T2-06 High flow, compact diaphragm pumps FEATURES | T2-06 High flow, compact diaphragm pumps FEATURES · Compact size, long life and efficiency · Single or twin head versions · Ideal for use in portable air and gas applications · Up to 6 or 12 lpm free flow, pressure up to 1.3 bar and vacuum up to 576 mbar |
Original | ||||
| solenoid valve | VSO® Low Flow Normally closed proportional solenoid valve FEATURES · 2-way normally closed · Applications where control is critical or flow is required below 600 sccm · Provides computer-automated calibrations and full calibration traceability · Uses either DC current or pulse width |
Original | ||||
| solenoid valve | Lone Wolf Normally open proportional solenoid valve FEATURES · 2-way normally open · Achieves rapid, stable performance · Enhances system control and patient comfort · Maintains ideal flow through normally open valve with thermal compensation · Extremely reliable |
Original | ||||
| solenoid valve | HF PRO High flow proportional solenoid valve FEATURES · 2-way normally closed · Capable of 60 lpm flow and pressures up to 50 psig · Face seal manifold mount or barbed body options · Proven performance to 35 million life cycles · Driven with DC current or pulse width |
Original | ||||
| Ten-X® 10 mm switching soleniod valve FEATURES · | Ten-X® 10 mm switching soleniod valve FEATURES · 3-way, 2 position (NO, NC & Distributor) · Optional ‘Hit and Hold’ drive electronics using pulse width modulation (PWM) at 25-32 kHz · Minimum flow of 8 lpm @ 6 psi and 22 lpm @ 30 psi · 10 mm single piece body design |
Original | ||||
|
|
||||||
| MD PRO Normally closed proportional solenoid | MD PRO Normally closed proportional solenoid valve FEATURES · 2-way normally closed · Offers automated calibration · Provides repeatability across its operating range · Offers a superior combination of value and performance · Rated for 10 million life cycles |
Original | ||||
| solenoid valve | VSO® Normally closed proportional solenoid valve FEATURES · 2-way normally closed · Offers operating pressure up to 150 psig and a range of orifice sizes · Satisfies a 0.2 sccm leakage specification of He for 100 million life cycles and offers high repeatability |
Original | ||||
| awm700 | AWM700 Series Mass flow sensor for gases FEATURES · Ranges 0…200 slpm1 · Actual mass flow sensing · 1…5 V output SERVICE To be used with dry gases only The AWM series is NOT designed for liquid flow and will be damaged by liquid flow through the sensor |
Original | ||||
| T2-05 Miniature diaphragm pumps FEATURES · | T2-05 Miniature diaphragm pumps FEATURES · Ultra-compact size, long life, and high efficiency · Ideal for use in portable air and gas applications · Quiet operation and low vibration · Intrinsically safe motor · Broad media compatibility · Contamination-free |
Original | ||||
| awm43000 | AWM43000 Series Mass flow sensor for gases FEATURES · Ranges 0…1000 sccm1 and 0…6 slpm2 · Actual mass flow sensing · 1…5 V output · Manifold mount/o-ring sealed SERVICE To be used with dry gases only The AWM series is NOT designed for liquid flow and will be damaged by liquid flow through |
Original | ||||
| awm42000 | AWM42000 Series Mass flow sensor for gases FEATURES · Ranges 0…±25 and 0…±1000 sccm1 · Bidirectional sensing · Actual mass flow sensing · Ceramic flow tube · Manifold mount/o-ring sealed SERVICE To be used with dry gases only. The AWM42150VH is a special sensor for |
Original | ||||
| nibp | PND Series Switching solenoid dump valve FEATURES · 2-way Normally Open exhaust valve in a small package size · Works well in miniature applications such as in Non-Invasive Blood Pressure (NIBP) devices · Provides small size and low cost · Offers low holding voltage |
Original | ||||
| awm90000 | AWM90000 Series Mass flow sensor for gases FEATURES · Ranges 0…±200 sccm1 or 0…±2 "H2O (0…±5 mbar) · Bidirectional sensing · Actual mass flow sensing · Low differential pressure sensing SERVICE To be used with dry gases only The AWM series is NOT designed for liquid |
Original | ||||
| lqx16 | LQX16 16 mm isolated diaphragm solenoid valves FEATURES · 3-way universal valves · EPDM or FKM elastomer options · 16 mm centreline spacing; ideal for manifold mounting · Low internal volume · Manifold sub-base; option of fluid connectors on single or multiple station |
Original | ||||
| XYA Series Oxygen sensors FEATURES · Oxygen | XYA Series Oxygen sensors FEATURES · Oxygen pressure range 2 mbar…3 bar · Zirconium dioxide (ZrO2) sensing elements · Non-consumptive technology · Integral heating element · No need for temperature stabilisation · No reference gas required · Function testing and calibration in |
Original | ||||