SCIENTIFIC IMAGING TEC Search Results
SCIENTIFIC IMAGING TEC Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| TMS320DM640AGNZ4 | Texas Instruments | Video/Imaging Fixed-Point Digital Signal Processor 548-FCBGA |
|
||
| TMS320DM642AZNZA6 | Texas Instruments | Video/Imaging Fixed-Point Digital Signal Processor 548-FCBGA |
|
|
|
| TMS320DM642AZDK7HK | Texas Instruments | Video/Imaging Fixed-Point Digital Signal Processor 548-FCBGA |
|
|
|
| TMS320DM640AZDKA4 | Texas Instruments | Video/Imaging Fixed-Point Digital Signal Processor 548-FCBGA |
|
|
|
| TMS320DM641AZNZ5 | Texas Instruments | Video/Imaging Fixed-Point Digital Signal Processor 548-FCBGA |
|
|
Documents mentioning SCIENTIFIC IMAGING TEC
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| su512lse | MityCCD High Performance Cameras MityCCD-SU256LSB / SU512LSE APPLICATIONS • Embedded Instrumentation • Raman Spectroscopy • Low Light Imaging Applications • Portable Scientific Instrumentation • Astronomy FEATURES • High Performance Scientific Camera |
Original | ||||
| ccd231 | CCD231-84 Back Illuminated Scientific CCD Sensor 4096 x 4096 Pixels, Four Outputs Non-inverted Mode Operation INTRODUCTION This device extends e2v’s family of scientific CCD sensors. The CCD231 has been designed to provide a large image area for demanding astronomical and scientific imaging |
Original | ||||
| ccd231 | CCD231-84 Back Illuminated Scientific CCD Sensor 4096 x 4096 Pixels, Four Outputs, Non-inverted Mode Operation INTRODUCTION This device extends e2v’s family of scientific CCD sensors. The CCD231 has been designed to provide a large image area for demanding astronomical and scientific imaging |
Original | ||||
| ccd230-84 | CCD230-84 Scientific CCD Sensor Front Illuminated, 4096 x 4096 Pixels, Four Outputs and Inverted Mode Operation INTRODUCTION This device extends e2v’s family of scientific CCD sensors. The CCD230 has been designed to provide a large image area for demanding scientific imaging applications. The low |
Original | ||||
| ccd230 | CCD230-42 Front Illuminated Scientific CCD Sensor 2048 x 2048 Pixels, Four Outputs and Inverted Mode Operation INTRODUCTION This device extends e2v’s family of scientific CCD sensors. The CCD230 has been designed to provide a large image area for demanding scientific imaging applications. The low |
Original | ||||
| ccd230-42 | CCD230-42 Front Illuminated Scientific CCD Sensor 2048 x 2048 Pixels, Four Outputs and Inverted Mode Operation INTRODUCTION This device extends e2v’s family of scientific CCD sensors. The CCD230 has been designed to provide a large image area for demanding scientific imaging applications. The low |
Original | ||||
| CCD230-84 Scientific CCD Sensor Back Illuminated, | CCD230-84 Scientific CCD Sensor Back Illuminated, 4096 x 4096 Pixels, Four Outputs and Inverted Mode Operation INTRODUCTION This device extends e2v’s family of scientific CCD sensors. The CCD230 has been designed to provide a large image area for demanding scientific imaging applications. Backilluminated spectral response combined with low readout |
Original | ||||
| ccd230-42 | CCD230-42 Back Illuminated Scientific CCD Sensor 2048 x 2048 Pixels, Four Outputs and Inverted Mode Operation INTRODUCTION This device extends e2v’s family of scientific CCD sensors. The CCD230 has been designed to provide a large image area for demanding scientific imaging applications. Backilluminated spectral response combined with low read-out |
Original | ||||
| ccd230 | CCD230-42 Back Illuminated Scientific CCD Sensor 2048 x 2048 Pixels, Four Outputs and Inverted Mode Operation INTRODUCTION This device extends e2v’s family of scientific CCD sensors. The CCD230 has been designed to provide a large image area for demanding scientific imaging applications. Backilluminated spectral response combined with low read-out |
Original | ||||
| ccd230-42 | CCD230-42 Back Illuminated Scientific CCD Sensor 2048 x 2048 Pixels, Four Outputs and Inverted Mode Operation INTRODUCTION This device extends e2v’s family of scientific CCD sensors. The CCD230 has been designed to provide a large image area for demanding scientific imaging applications. Backilluminated spectral response combined with low read-out |
Original | ||||
| cis101 | CIS101-00-*-M05 2M Pixel CMOS Scientific Imaging Sensor For Space Applications INTRODUCTION SUMMARY SPECIFICATION The CIS101 Active Pixel Sensor is e2v’s first offering for space imaging applications with this technology. The advantages of the APS sensor over a CCD are lower power |
Original | ||||
| New CCD for Low-Light Scientific Applications | New CCD for Low-Light Scientific Applications High-Speed InGaAs APD + TIA ROSA Highly Sensitive Image Intensifier with Large Active Area Flat-Panel Sensor Product Line Extended The Improved Macro Imaging System AEQUORIA Imaging-Based Plate Reader FDSS for HighThroughput |
Original | ||||
| changing the game | In early 2001, the scientific imaging community turned to electron multiplying CCDs—the new superstars of detector technology—to realize breakthroughs in low light imaging. This method worked brilliantly…until now. Changing the Game Authors: Stephanie Fullerton, Ph.D., Keith Bennett, Ph.D. (Hamamatsu Corporation), Eiji Toda, Teruo Takahashi (Hamamatsu Photonics K.K.) |
Original | ||||
| scientific imaging technologies | SCIENTIFIC IMAGING TECHNOLOGIES, INC. 2048 x 2048 pixel format (24µm square) ■ Front-illuminated or thinned, back-illuminated versions ■ Unique thinning and Quantum Efficiency enhancement processes ■ Excellent QE from IR to UV ■ Anti-reflection coating |
Original | ||||
|
|
||||||
| DALSA FTF3041M Full Frame CCD Sensor Overview A | DALSA FTF3041M Full Frame CCD Sensor Overview A highly sensitive 12 megapixel full frame CCD sensor for demanding medical and scientific digital imaging applications. Taking full advantage of DALSA’s advanced CCD manufacturing processes, the 12 megapixel |
Original | ||||