Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    SCHAFFNER IT 248 Search Results

    SCHAFFNER IT 248 Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    Schaffner it 153

    Abstract: SCHAFFNER IT 248 Schaffner it 245 Schaffner Pulse transformers schaffner pulse transformer SCHAFFNER IT 246 IT 258 IT 255 SCHAFFNER IT 364
    Contextual Info: Pulse transformers IT series Pulse transformer with single secondary winding n Galvanic separation of drive and power circuit n Voltage resistance up to 8kV n Ignition current up to 3A n Turns ratio up to 3:1 Technical specifications Nominal operating voltage:


    Original
    40khz500khzup/50hz/2sschaffner it 153+8schaffner it 248schaffner it 245schaffner pulse transformersschaffner pulse transformerschaffner it 246it 258it 255schaffner it 364 PDF

    Contextual Info: Pulse Transformer with Single Secondary Winding Pulse Transformers IT series Galvanic separation of drive and power circuit Voltage resistance up to 8 kV Approvals Ignition current up to 3 A Turns ratio up to 3:1 IT pulse transformers are designed to offer you


    Original
    PDF

    Contextual Info: DATASHEET Pulse Transformers IT series Pulse Transformer with Single Secondary Winding Galvanic separation of drive and power circuit Voltage resistance up to 8 kV Approvals Ignition current up to 3 A Turns ratio up to 3:1 IT pulse transformers are designed to offer you


    Original
    PDF

    Contextual Info: Pulse Transformer with Single Secondary Winding Pulse Transformers IT series Galvanic separation of drive and power circuit Voltage resistance up to 8 kV Approvals Ignition current up to 3 A Turns ratio up to 3:1 IT pulse transformers are designed to offer you


    Original
    PDF

    Contextual Info: Pulse Transformers IT series Pulse Transformer with Single Secondary Winding Galvanic separation of drive and power circuit Approvals Voltage resistance up to 8kV Ignition current up to 3A Turns ratio up to 3:1 Technical specifications Flammability corresponding to:


    Original
    produ76185 PDF

    Contextual Info: Pulse Transformers IT series Pulse Transformer with Single Secondary Winding Galvanic separation of drive and power circuit Approvals Voltage resistance up to 8kV Ignition current up to 3A Turns ratio up to 3:1 Typical electrical schematic Technical specifications


    Original
    up/50hz/2s PDF

    Schaffner it 153

    Abstract: SCHAFFNER IT 248 Schaffner it 245 IT 255 CK 66 94V-0 it246
    Contextual Info: Pulse Transformers IT series Pulse Transformer with Single Secondary Winding n Galvanic separation of drive and power circuit n Voltage resistance up to 8kV n Ignition current up to 3A n Turns ratio up to 3:1 Technical specifications Nominal operating voltage:


    Original
    40khz500khzup/50hz/2sschaffner it 153+5schaffner it 248schaffner it 245it 255ck 66 94v-0it246 PDF

    Contextual Info: DATASHEET Pulse Transformers IT series Pulse Transformer with Single Secondary Winding Galvanic separation of drive and power circuit Voltage resistance up to 8 kV Approvals Ignition current up to 3 A Turns ratio up to 3:1 IT pulse transformers are designed to offer you


    Original
    PDF

    Contextual Info: Pulse Transformer with Single Secondary Winding Pulse Transformers IT series Galvanic separation of drive and power circuit Voltage resistance up to 8 kV Approvals Ignition current up to 3 A Turns ratio up to 3:1 IT pulse transformers are designed to offer you


    Original
    PDF

    Contextual Info: Pulse Transformers IT series Pulse Transformer with Single Secondary Winding Galvanic separation of drive and power circuit Approvals Voltage resistance up to 8kV Ignition current up to 3A Turns ratio up to 3:1 Technical specifications Flammability corresponding to:


    Original
    produ76185 PDF

    Contextual Info: Pulse Transformers IT series Pulse Transformer with Single Secondary Winding Galvanic separation of drive and power circuit Approvals Voltage resistance up to 8kV Ignition current up to 3A Turns ratio up to 3:1 Technical specifications Flammability corresponding to:


    Original
    produ76185 PDF

    SCHAFFNER IT 246

    Contextual Info: EMC/EMI Products IT series Pulse Transformer with Single Secondary Winding Galvanic separation of drive and power circuit Approvals Voltage resistance up to 8kV Ignition current up to 3A Turns ratio up to 3:1 Typical electrical schematic Technical specifications


    Original
    40khz500khzup/50hz/2stransforme42+1schaffner it 246 PDF

    Schaffner it 153

    Abstract: Schaffner it 245 Schaffner* it 332 Schaffner Pulse transformers SCHAFFNER IT 248 transformateurs schaffner pulse transformer IT 313 IT 213 IT 314
    Contextual Info: Pulse Transformers Pulse Transformers Impulstransformatoren Transformateurs d’impulsion www.schaffner.com SCHAFFNER Pulse transformers CONTENTS INHALT TABLE DES MATIERES General information Allgemeine Informationen Généralités Introduction.2


    Original
    690-065bschaffner it 153schaffner it 245schaffner* it 332+7schaffner pulse transformersschaffner it 248transformateursschaffner pulse transformerit 313it 213it 314 PDF

    Contextual Info: Pulse Transformer with Single Secondary Winding Pulse Transformers IT series Galvanic separation of drive and power circuit Voltage resistance up to 8 kV Approvals Ignition current up to 3 A Turns ratio up to 3:1 IT pulse transformers are designed to offer you


    Original
    PDF

    SCHAFFNER IT 248

    Contextual Info: ECOsine Compact Economy Line of Passive Harmonic Filters Harmonic Filters FN 3418 Economy line of passive harmonic filters for THID <10 % Approvals Help to comply with EN61000-3-12, IEEE-519 and other PQ standards Support an efficient utilization of electrical system


    Original
    en61000-3-12ieee-519schaffner it 248 PDF

    Contextual Info: DATASHEET Economy Line FN 3416 ECOsine Compact Economy Line of Passive Harmonic Filters Economy line of passive harmonic filters for THID <10 % Approvals Help to comply with EN61000-3-12, IEEE-519 and other PQ standards Support an efficient utilization of electrical system


    Original
    en61000-3-12ieee-519c/500vmil-hb-217f PDF

    Contextual Info: ECOsine Compact Economy Line of Passive Harmonic Filters Harmonic Filters FN 3416 Economy line of passive harmonic filters for THID <10 % Approvals Help to comply with EN61000-3-12, IEEE-519 and other PQ standards Support an efficient utilization of electrical system


    Original
    en61000-3-12ieee-519ul508en61558-2-20+3lvd2006c/500vmil-hb-217f PDF

    Contextual Info: Harmonic Filters FN 3416 ECOsine Compact Economy Line of Passive Harmonic Filters Economy line of passive harmonic filters for THID <10 % Approvals Help to comply with EN61000-3-12, IEEE519 and other PQ standards Support an efficient utilization of electrical


    Original
    en61000-3-12ieee519c/500vmil-hb-217f+1protection32 PDF

    Contextual Info: DATASHEET Harmonic Filters FN 3416 ECOsine Compact Economy Line of Passive Harmonic Filters Economy line of passive harmonic filters for THID <10 % Approvals Help to comply with EN61000-3-12, IEEE-519 and other PQ standards Support an efficient utilization of electrical system


    Original
    en61000-3-12ieee-519c/500vmil-hb-217f PDF

    Contextual Info: DATASHEET Economy Line FN 3418 ECOsine Compact Economy Line of Passive Harmonic Filters Economy line of passive harmonic filters for THID <10 % Approvals Help to comply with EN61000-3-12, IEEE-519 and other PQ standards Support an efficient utilization of electrical system


    Original
    en61000-3-12ieee-519ul508en61558-2-20+3lvd2006c/500vmil-hb-217f PDF

    Contextual Info: ECOsine Compact Economy Line of Passive Harmonic Filters Harmonic Filters FN 3418 Economy line of passive harmonic filters for THID <10 % Approvals Help to comply with EN61000-3-12, IEEE-519 and other PQ standards Support an efficient utilization of electrical system


    Original
    en61000-3-12ieee-519 PDF

    Contextual Info: Pulse Transformer with Single Secondary Winding Pulse Transformers IT series Galvanic separation of drive and power circuit Voltage resistance up to 8 kV Approvals Ignition current up to 3 A Turns ratio up to 3:1 IT pulse transformers are designed to offer you


    Original
    PDF

    Contextual Info: Harmonic Filters FN 3418 ECOsine Compact Economy Line of Passive Harmonic Filters Economy line of passive harmonic filters for THID <10 % Approvals Help to comply with EN61000-3-12, IEEE-519 and other PQ standards Support an efficient utilization of electrical system capacity


    Original
    en61000-3-12ieee-519c/500vmil-hb-217f+1de76185 PDF

    fn 155

    Abstract: Schaffner it 245 motor schaffner fn 530 filter IT 243 SCHAFFNER FN 660 FN 354 Schaffner* it 332 SCHAFFNER Schaffner FN 3100 SCHAFFNER FN 401
    Contextual Info: Short Form Components Filters, Chokes, Feedthrough Components & Pulse Transformers Filter, Drosseln, Durchführungskomponenten & Impulstransformatoren Filtres, Selfs, Composants de Traversée & Transformateurs d’impulsion www.schaffner.com Product selection chart


    Original
    212series213series690-061ifn 155+9schaffner it 245motor schaffner fn 530 filterit 243schaffner fn 660fn 354schaffner* it 332schaffnerschaffner fn 3100schaffner fn 401 PDF