Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    SAFETY MODULES Search Results

    SAFETY MODULES Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    DE6B3KJ101KA4BE01J
    Murata Manufacturing Co Ltd Safety Standard Certified Lead Type Disc Ceramic Capacitors for Automotive PDF
    DE6B3KJ331KB4BE01J
    Murata Manufacturing Co Ltd Safety Standard Certified Lead Type Disc Ceramic Capacitors for Automotive PDF
    DE6E3KJ102MN4A
    Murata Manufacturing Co Ltd Safety Standard Certified Lead Type Disc Ceramic Capacitors for Automotive PDF
    DE6E3KJ472MA4B
    Murata Manufacturing Co Ltd Safety Standard Certified Lead Type Disc Ceramic Capacitors for Automotive PDF
    DE6B3KJ331KA4BE01J
    Murata Manufacturing Co Ltd Safety Standard Certified Lead Type Disc Ceramic Capacitors for Automotive PDF

    SAFETY MODULES Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    xps-ecp

    Abstract: XPS-ECP5131 XPS-ECM5131 preventa xps IEC 947-5-1 VDE 0660 preventa safety XPS-ECM3431 IEC 947-5-1 VDE 0660 LIMIT SWITCH IEC-947-5-1 AC15 B300 B300
    Contextual Info: Components for safety applications Preventa safety modules for increasing the number of safety contacts Operating principle, characteristics Operating principle 1 XPS-ECi safety modules, for increasing the number of safety contacts, are available as attachments for Preventa XPS


    Original
    U1-13 U1-23. xps-ecp XPS-ECP5131 XPS-ECM5131 preventa xps IEC 947-5-1 VDE 0660 preventa safety XPS-ECM3431 IEC 947-5-1 VDE 0660 LIMIT SWITCH IEC-947-5-1 AC15 B300 B300 PDF

    AZR 31 To

    Abstract: AZR31T0 a1232 AZR31R2 hella Schmersal azr31t2 AZR31T2 AZR 31 T2 murrelektronik Schmersal T2
    Contextual Info: steute a SEHfTlEnSFILcompany Safety modules AZR. Emergency stop relay Safety gate monitor Two-Hand safety relay SAFETY IN SYSTEM: PROTECTION FOR MAN AND MACHINE! Risk analysis System safety: Man and machine protection The machine directive 89/392/EEC applicable


    OCR Scan
    89/392/EEC) prEN954-1 FIN-00701 S-43524 AZR 31 To AZR31T0 a1232 AZR31R2 hella Schmersal azr31t2 AZR31T2 AZR 31 T2 murrelektronik Schmersal T2 PDF

    Contextual Info: Safety Modules Safety Gate and Safety Magnetic Sensor Types NSO02D, NSO13D • Safety Category 4, Performance Level e, according to EN 13849-1 • Safety Category 4 according to EN 954-1 • Category 0 Emergency Stop EN 60204-1 • Input type: 2 NO • 2 x 6 A NO safety outputs (NSO02D)


    Original
    NSO02D, NSO13D NSO02D) NSO13D) NSO02D NSO13D PDF

    ABB time delay device for undervoltage release

    Contextual Info: Catalog 2013 ABB Safety Handbook Machine Safety - Jokab Safety products ABB Safety Handbook Machine Safety - Jokab Safety products Introduction 1 Directives and Standards, PL, SISTEMA, SIL, Training Pluto Safety PLC 2 Pluto, Gateway, Safe Encoder, IDFIX, program examples


    Original
    2TLC172001C0202 ABB time delay device for undervoltage release PDF

    WIELAND SNA 4043K

    Abstract: WIELAND SNA 4044K 4064K
    Contextual Info: Safety switching devices SNA 4043K /SNA 4063K / SNA 4044K / SNA 4064K safety safety Emergency stop and safety gate monitor Notes The safety switching devices of our SNA product line are used to monitor safety sensors emergency stop buttons, safety gate switches, etc. , feature a large number of safety


    Original
    4043K 4063K 4044K 4064K 015inal 4043K-A 4043K-C 4043K WIELAND SNA 4043K WIELAND SNA 4044K 4064K PDF

    1791DS

    Abstract: smartguard 600 SMARTGUARD 600 CONTROLLER RSNETWORX CONFIGURATION programming logic controller
    Contextual Info: PRODUCT PROFILE SmartGuard 600 Safety Controller The SmartGuard 600 safety controller is a general purpose programmable safety controller designed for safety applications that require some complex logic allowing for more advanced safety functionality. It features 16 safety-rated inputs, 8 safety-rated


    Original
    PDF

    XPS ar

    Abstract: AR351144P iso 14119 diagnost XPSAR371144 XPSar311144p xps-ar311144 XPSAR311144 en iso 13850 DC-13 emergency leds
    Contextual Info: Safety automation system solutions Operating principle, characteristics Preventa safety modules type XPS AR For Emergency stop, switch or safety light curtain monitoring Operating principle Safety modules XPS AR meet the requirements of category 4 of the standard


    Original
    954-1/EN/ISO 1088/ISO category34 S33-S34 Y31/Y32 Y31/Y35 Y31/Y64 Y31/Y74 XPS ar AR351144P iso 14119 diagnost XPSAR371144 XPSar311144p xps-ar311144 XPSAR311144 en iso 13850 DC-13 emergency leds PDF

    Contextual Info: Two hand safety Modules ND12D • Safety Category 4, Performance Level e according to EN13849-1 • Safety Category III C according to EN 574 • Safety Category 4 according to EN 954-1 • 2 NO safety outputs • 1 PNP auxiliary output • 1 NC relay auxiliary output


    Original
    ND12D EN13849-1 ND12D110CG, ND12D230CG S11-S12-S22 S21-S12-S22 PDF

    banner imt-9a

    Abstract: IM-T-9A im-t-11a DC-13 EN954-1 ISO13849-1 ossd FSD IEC61810-1
    Contextual Info: Models IM-T-9A and IM-T-11A Interface Modules Interface Modules for use with a Primary Safety Device • Interface Modules provide isolated safety output contacts for a primary safety device e.g., a safety light screen or safety module which has solid-state or hard contact outputs


    Original
    IM-T-11A Directive98/37/EEC) banner imt-9a IM-T-9A DC-13 EN954-1 ISO13849-1 ossd FSD IEC61810-1 PDF

    Contextual Info: Industrial Controls Safety Engineering SIRIUS 3SK1 Safety Relays Manual Edition 02/2014 Answers for industry. 3SK1 safety relays 1 _ Introduction Product-specific safety 2 _ information Industrial Controls Safety engineering


    Original
    A5E02526190021A/RS-AB/002 3ZX1012-0SK11-0AC0 PDF

    xps-dmb

    Abstract: xps-dme XPSDMB1132 XPSDMB1132P XPSDME1132 XPSDME1132P ISO13849-1 xps-dme1132P ISO-13849-1 C300
    Contextual Info: Safety automation system solutions Operating principle, characteristics Preventa safety relay modules types XPSDMB, XPSDME For non-contact safety interlock coded magnetic switch monitoring Operating principle Safety modules XPSDMB and XPSDME are specifically designed for monitoring


    Original
    954-1/ISO13849-1, XPSDMB1132 XPSDME1132 XPSDMB1132p XPSDME1132P xps-dmb xps-dme XPSDMB1132 XPSDMB1132P XPSDME1132 XPSDME1132P ISO13849-1 xps-dme1132P ISO-13849-1 C300 PDF

    XPS-ASf

    Abstract: XPS-ASF5142 XPS-AS XPS-ASF3442 XPS-Apf xpsasf5142 XPS-ASF3742 Y33-Y34 xps-bc S41-S42
    Contextual Info: Components for safety applications Preventa safety modules for emergency stop, limit switch, two-hand control, safety mat and edge monitoring Operating principle, characteristics Operating principle see page 1/12 1 Characteristics Type XPS-ASF Product designed for use in safety


    Original
    S11-S12, S21-S22 S11-B1 S21-S22 S11-S12) S33-S34 S21-S22) Y33/43 XPS-ASf XPS-ASF5142 XPS-AS XPS-ASF3442 XPS-Apf xpsasf5142 XPS-ASF3742 Y33-Y34 xps-bc S41-S42 PDF

    EN1050

    Abstract: IEC 947-5-1 VDE 0660 LIMIT SWITCH XPS-FB5111 xps* preventa xps-fb XPSFB3711 Electronic fuse linked state machines electromagnetic lock Y4 S4
    Contextual Info: Components for safety applications Preventa safety modules for electrical monitoring of limit switches combined in pairs Operating principle Operating principle 1 Preventa safety module XPS-FB meets the safety requirements for monitoring the operation of 2 limit switches used on


    Original
    PDF

    Contextual Info: Safety Modules Emergency Stop and Safety Gate Types NES02D, NES13D Screw, fixed Screw, detachable • Safety Category 4, Performance Level e according to EN 13849-1 • Safety Category 4 according to EN 954-1 • Category 0 Emergency Stop EN 60204-1 • 2 x 6 A NO safety outputs (NES02D)


    Original
    NES02D, NES13D NES02D) NES13D) PDF

    Safety Module

    Abstract: Light Curtains Safety Modules 98/37/EC
    Contextual Info: Safety Modules Light curtains Types NLG02D, NLG13D Screw, fixed Screw, detachable • Safety Category 4, Performance Level e, according to EN 13849-1 • Safety Category 4 according to EN 954-1 • 2 x 6 A NO safety outputs NLG02D • 3 x 6 A NO safety outputs and 1 x 6 A NC auxiliary


    Original
    NLG02D, NLG13D NLG02D) NLG13D) NLG02D NLG13D Safety Module Light Curtains Safety Modules 98/37/EC PDF

    Schmersal scr 1r

    Abstract: SCR 1R wiring diagram contactor with push button Schmersal Y2 TRANSISTOR emergency light circuit SCR emergency light circuit using SCR DIN EN 954-1 Schmersal scM 3RQ start push button
    Contextual Info: 10. 10.8 10.8.8 Safety monitoring modules Safety monitoring modules for special applications Monitoring of safety light grids/curtains and safety laser scanners using SCR 1R Features Dimensions Part number Approvals SK4 • Control Category 4 to EN 954-1 • Feedback circuit to monitor


    Original
    PDF

    SNO4062K

    Abstract: SNO4003K SNV4063KL SNZ4052K SNA4043K WIELAND SNA 4063K SNV4076SL SNV4063KL-A SNA4043K-C SNA4064K
    Contextual Info: safety Safety Products Safety for all applications 0152.5 E 03/07 Safety switching devices from Wieland Electric Wieland Electric provides safety switching devices for all daily industrial use applications. Requiring only little space they combine excellent performance features


    Original
    IP20/IP65. SNO4062K SNO4003K SNV4063KL SNZ4052K SNA4043K WIELAND SNA 4063K SNV4076SL SNV4063KL-A SNA4043K-C SNA4064K PDF

    Safety Modules

    Abstract: NES13D marking s34 NES02D EN1088 S11-S12 b24s en 60204-1
    Contextual Info: Safety Modules Emergency Stop and Safety Gate Types NES02D, NES13D • • • • • • • • • • Screw, fixed Safety Category 4 according to EN 954-1 Category 0 Emergency Stop EN 60204-1 2 x 6 A NO safety outputs (NES02D) 3 x 6 A NO safety outputs and 1 x 6 A NC auxiliary output (NES13D)


    Original
    NES02D, NES13D NES02D) NES13D) EN1088. NES02D. NES13D. Safety Modules NES13D marking s34 NES02D EN1088 S11-S12 b24s en 60204-1 PDF

    S21-S22-S23

    Abstract: EN574 y1 npn S11-S12-S13
    Contextual Info: Two hand safety Modules MD1D • • • • • • • • • Safety Category III C according to EN 574 Safety Category 4 according to EN 954-1 Redundant circuit 2 NO safety outputs Dual channel inputs Automatic RESET Self monitoring Failure diagnosis by LEDs


    Original
    24Vdc/Vac S21S23 S11-S12-S13 S21-S22-S23 S21-S22-S23 EN574 y1 npn S11-S12-S13 PDF

    S11-S12

    Abstract: nds12b
    Contextual Info: Safety Modules Emergency Stop and Safety Gate Type NDS12B Screw, fixed Screw, detachable • Safety Category 2 according to EN 13849-1: 2007 • Category 0 Emergency Stop EN 60204-1 for 1 istantaneous safety output • Category 1 Emergency Stop (EN 60204-1) for 1 delayed


    Original
    NDS12B S11-S12 nds12b PDF

    1SAR501331R0005

    Abstract: 1SAR501331R0001 PLC WIRING DIAGRAM OF ABB C581 C579 IEC 60947-5-1 push button abb contactors M3K1 EMERGENCY OFF PUSH BUTTON automatic sliding doors sensor
    Contextual Info: Data sheet Safety relay C581 Safety relays C581 with relay safety contacts / enabling circuits provide reliable switch off in hazardous situations and make the efficient configuration of continuous safety chains possible. This safety relays carry out EMERGENCYSTOP switch off or protective door /


    Original
    D0201 01/10-x-xxx) 1SAR501331R0005 1SAR501331R0001 PLC WIRING DIAGRAM OF ABB C581 C579 IEC 60947-5-1 push button abb contactors M3K1 EMERGENCY OFF PUSH BUTTON automatic sliding doors sensor PDF

    Pilz safety relay

    Abstract: pnoz 11 PILZ pnoz PILZ pnoz 11 relay 1210 S33S3 S11-S12 two-hand PILZ PNOZ S11 Safety relay PILZ
    Contextual Info: E-STOP relay, safety gate monitor Up to Category 4, EN 954-1 PNOZ 11 Safety relay for monitoring E-STOP pushbuttons and safety gates. Approvals PNOZ 11 Unit features Safety features ` Positive-guided relay outputs: – 7 safety contacts N/O , instantaneous


    Original
    NSG-D-2-058-12/04 Pilz safety relay pnoz 11 PILZ pnoz PILZ pnoz 11 relay 1210 S33S3 S11-S12 two-hand PILZ PNOZ S11 Safety relay PILZ PDF

    Emergency

    Abstract: NA13D NA13D230CG NA13D230 s34 diode NA13 NA13D110CG S11-S12 Polyamid 12
    Contextual Info: Emergency Stop and Safety Gate Modules NA13D • • • • • • • • • • Ordering Key Product Description Emergency Stop and Safety Gate modules according to EN 60204-1, EN 292-1/-2, EN 418 and EN 1088. This family of safety module in Safety Category 4,


    Original
    NA13D S21-S22 NA13D230 NA1/3-D/230 S33-S34 NA13D110CG NA13D230CG Emergency NA13D NA13D230CG NA13D230 s34 diode NA13 NA13D110CG S11-S12 Polyamid 12 PDF

    XPSAC5121P

    Abstract: XPS-AC5121 XPSAC5121 XPS-AC 7408 3- input 7408 XPSAC3721P XPSAC3721 XPS-AC3721 XPSAC3421P
    Contextual Info: Operating principle, characteristics Safety automation system solutions Preventa safety relay modules type XPSAC For Emergency stop and switch monitoring Operating principle Safety modules XPSAC are used for monitoring Emergency stop circuits conforming


    Original
    EN/ISO13850 1088/ISO14119. XPSAC1321 XPSAC3421 XPSAC3721 XPSAC5121P XPSAC1321P XPSAC3421P XPSAC3721P XPSAC5121P XPS-AC5121 XPSAC5121 XPS-AC 7408 3- input 7408 XPSAC3721P XPSAC3721 XPS-AC3721 XPSAC3421P PDF