Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    SAFETY MODULE Search Results

    SAFETY MODULE Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    LP87644Q1EVM
    Texas Instruments Automotive 1+1+1+1-phase four output functional safety compliant buck converter evaluation module Visit Texas Instruments Buy
    SF-10GSFPPLCL-000
    Amphenol Cables on Demand Amphenol SF-10GSFPPLCL-000 SFP+ Optical Module - 10GBASE-SR (up to 300m/984') SFP+ Multimode Optical Transceiver Module (Duplex LC Connectors) - Cisco & HP Compatible PDF
    SF-SFP28LPB1W-0DB
    Amphenol Cables on Demand Amphenol SF-SFP28LPB1W-0DB SFP28 Loopback Adapter Module for SFP28 Port Compliance Testing - 0dB Attenuation & 1W Power Consumption PDF
    SF-SFPPLOOPBK-0DB
    Amphenol Cables on Demand Amphenol SF-SFPPLOOPBK-0DB SFP+ Loopback Adapter Module for SFP+ Port Compliance Testing - 0dB Attenuation & 0W Power Consumption PDF
    SF-SFPPLOOPBK-003.5
    Amphenol Cables on Demand Amphenol SF-SFPPLOOPBK-003.5 SFP+ Loopback Adapter Module for SFP+ Port Compliance Testing - 3.5dB Copper/Optical Cable Emulation PDF

    SAFETY MODULE Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    F39-MDG

    Abstract: Safety bus EN954-1 GS-ET-15 NL-2132 EN 50041 IEC 60947-5-1 limit switch
    Contextual Info: Safety Total solutions for industrial safety Safety light curtains Emergency stop buttons Safety relay units General-purpose limit switches Safety network systems Services for machine safety Safety switches Advanced Industrial Automation Safety sensors Safety switches


    Original
    f39-mdgsafety busen954-1gs-et-15+2nl-2132en 50041 iec 60947-5-1 limit switch PDF

    final de carrera

    Abstract: 3RK1904-2AB01 3RK1205-0B sensores de carrera puente h K45 S2 3RK1205-0BQ00-0AA3 FABRICANTE F 3RK1901-1AA00 led rojo
    Contextual Info: Kompaktmodul K45 2F-E Safety 3RK1205-0BQ00-0AA3 Compact Module K45 2F-E Safety Module compact K45 2F-E Safety Módulo compacto K45 2F-E Safety Modulo compatto K45 2F-E Safety Módulo compacto K45 2F-E Safety IEC 61508 EN 954-1 us IP 65/ IP 67 SAFETY AT WORK


    Original
    3rk1205-0bq00-0aa33rk1701-5kb16-0aa0ip65/ip673rk1901-2+9final de carrera3rk1904-2ab013rk1205-0bsensores de carrerapuente hk45 s2fabricante f3rk1901-1aa00led rojo PDF

    Contextual Info: EM-F-7G Safety Extension Module One-channel control with four safety output channels Features • Safety Extension Module provides additional safety outputs for a Primary Safety Device for example, an E-stop safety module or a two-hand control module • One-channel control


    Original
    PDF

    Contextual Info: EM-FD-7G Series Safety Extension Modules – Delayed Output One-channel control with four delayed safety output channels Features • Safety Extension Module provides additional safety outputs for a Primary Safety Device for example, an E-stop safety module or a two-hand control module


    Original
    en418 PDF

    xps-ecp

    Abstract: XPS-ECP5131 XPS-ECM5131 preventa xps IEC 947-5-1 VDE 0660 preventa safety XPS-ECM3431 IEC 947-5-1 VDE 0660 LIMIT SWITCH IEC-947-5-1 AC15 B300 B300
    Contextual Info: Components for safety applications Preventa safety modules for increasing the number of safety contacts Operating principle, characteristics Operating principle 1 XPS-ECi safety modules, for increasing the number of safety contacts, are available as attachments for Preventa XPS


    Original
    u1-13u1-23xps-ecpxps-ecp5131+8xps-ecm5131preventa xpsiec 947-5-1 vde 0660preventa safetyxps-ecm3431iec 947-5-1 vde 0660 limit switchiec-947-5-1 ac15 b300b300 PDF

    AZR 31 To

    Abstract: AZR31T0 a1232 AZR31R2 hella Schmersal azr31t2 AZR31T2 AZR 31 T2 murrelektronik Schmersal T2
    Contextual Info: steute a SEHfTlEnSFILcompany Safety modules AZR. Emergency stop relay Safety gate monitor Two-Hand safety relay SAFETY IN SYSTEM: PROTECTION FOR MAN AND MACHINE! Risk analysis System safety: Man and machine protection The machine directive 89/392/EEC applicable


    OCR Scan
    89/392/eecpren954-1fin-00701s-43524+10azr 31 toazr31t0a1232azr31r2hellaschmersal azr31t2azr31t2azr 31 t2murrelektronikschmersal t2 PDF

    Contextual Info: Safety Modules Safety Gate and Safety Magnetic Sensor Types NSO02D, NSO13D • Safety Category 4, Performance Level e, according to EN 13849-1 • Safety Category 4 according to EN 954-1 • Category 0 Emergency Stop EN 60204-1 • Input type: 2 NO • 2 x 6 A NO safety outputs (NSO02D)


    Original
    nso02dnso13d PDF

    ABB time delay device for undervoltage release

    Contextual Info: Catalog 2013 ABB Safety Handbook Machine Safety - Jokab Safety products ABB Safety Handbook Machine Safety - Jokab Safety products Introduction 1 Directives and Standards, PL, SISTEMA, SIL, Training Pluto Safety PLC 2 Pluto, Gateway, Safe Encoder, IDFIX, program examples


    Original
    2tlc172001c0202abb time delay device for undervoltage release PDF

    Contextual Info: IM-T-9A and IM-T-11A Interface Modules Interface modules for use with a primary safety device • Interface Modules provide isolated safety output contacts for a primary safety device e.g., a safety light screen or safety module which has solid-state or


    Original
    im-t-11a PDF

    Contextual Info: SRM Safety Relay Module Demand Moore Reliability September 2014 Description Part of Moore Industries’ FS FUNCTIONAL SAFETY SERIES, the SRM Safety Relay Module provides a high level of availability for safety-critical applications and as a part of Safety Instrumented Systems SIS .


    Original
    PDF

    WIELAND SNA 4043K

    Abstract: WIELAND SNA 4044K 4064K
    Contextual Info: Safety switching devices SNA 4043K /SNA 4063K / SNA 4044K / SNA 4064K safety safety Emergency stop and safety gate monitor Notes The safety switching devices of our SNA product line are used to monitor safety sensors emergency stop buttons, safety gate switches, etc. , feature a large number of safety


    Original
    4043k4063k4044k4064k+5015inal4043k-a4043k-cwieland sna 4043kwieland sna 4044k PDF

    Contextual Info: Safety Modules Safety Gate and Safety Magnetic Sensor Types NSC02D, NSC13D • Safety Category 4, Performance Level e, according to EN 13849-1 • Safety Category 4 according to EN 954-1 • Category 0 Emergency Stop EN 60204-1 • Input type: 1 NO + 1 NC


    Original
    nsc02dnsc13d PDF

    1791DS

    Abstract: smartguard 600 SMARTGUARD 600 CONTROLLER RSNETWORX CONFIGURATION programming logic controller
    Contextual Info: PRODUCT PROFILE SmartGuard 600 Safety Controller The SmartGuard 600 safety controller is a general purpose programmable safety controller designed for safety applications that require some complex logic allowing for more advanced safety functionality. It features 16 safety-rated inputs, 8 safety-rated


    Original
    1791dssmartguard 600smartguard 600 controllerrsnetworx configuration+1programming logic controller PDF

    Contextual Info: Product data sheet Characteristics XPSMC16ZP safety controller XPS-MC - 24 V DC - 16 input 32 LEDs signalling Commercial Status Commercialised Range of product Preventa Safety automation Product or component type Configurable safety controller Safety module name


    Original
    xpsmc16zp954-1/en/1760-1/iso574/iso+1954-1/en/iso PDF

    Contextual Info: Product data sheet Characteristics XPSMC32Z safety controller XPS-MC - 24 V DC - 32 input 46 LEDs signalling Commercial Status Commercialised Range of product Preventa Safety automation Product or component type Configurable safety controller Safety module name


    Original
    xpsmc32z954-1/en/1760-1/iso574/iso+1954-1/en/iso PDF

    Contextual Info: Product data sheet Characteristics XPSAXE5120P module XPSAXE - stop and switch monitoring 24 V DC Commercial Status Commercialised Range of product Preventa Safety automation Product or component type Preventa safety module Safety module name XPSAXE Safety module


    Original
    xpsaxe5120p1088/iso PDF

    XPSAX

    Contextual Info: Product data sheet Characteristics XPSAXE5120C module XPSAXE - stop and switch monitoring 24 V DC Commercial Status Commercialised Range of product Preventa Safety automation Product or component type Preventa safety module Safety module name XPSAXE Safety module


    Original
    xpsaxe5120c1088/isoxpsax PDF

    Contextual Info: Two hand safety Modules ND12D • Safety Category 4, Performance Level e according to EN13849-1 • Safety Category III C according to EN 574 • Safety Category 4 according to EN 954-1 • 2 NO safety outputs • 1 PNP auxiliary output • 1 NC relay auxiliary output


    Original
    nd12den13849-1nd12d110cgnd12d230cg+2s11-s12-s22s21-s12-s22 PDF

    banner imt-9a

    Abstract: IM-T-9A im-t-11a DC-13 EN954-1 ISO13849-1 ossd FSD IEC61810-1
    Contextual Info: Models IM-T-9A and IM-T-11A Interface Modules Interface Modules for use with a Primary Safety Device • Interface Modules provide isolated safety output contacts for a primary safety device e.g., a safety light screen or safety module which has solid-state or hard contact outputs


    Original
    im-t-11adirective98/37/eecbanner imt-9aim-t-9a+5dc-13en954-1iso13849-1ossd fsdiec61810-1 PDF

    Contextual Info: Industrial Controls Safety Engineering SIRIUS 3SK1 Safety Relays Manual Edition 02/2014 Answers for industry. 3SK1 safety relays 1 _ Introduction Product-specific safety 2 _ information Industrial Controls Safety engineering


    Original
    a5e02526190021a/rs-ab/0023zx1012-0sk11-0ac0 PDF

    xps-dmb

    Abstract: xps-dme XPSDMB1132 XPSDMB1132P XPSDME1132 XPSDME1132P ISO13849-1 xps-dme1132P ISO-13849-1 C300
    Contextual Info: Safety automation system solutions Operating principle, characteristics Preventa safety relay modules types XPSDMB, XPSDME For non-contact safety interlock coded magnetic switch monitoring Operating principle Safety modules XPSDMB and XPSDME are specifically designed for monitoring


    Original
    954-1/iso13849-1xpsdmb1132xpsdme1132xpsdmb1132p+7xpsdme1132pxps-dmbxps-dmeiso13849-1xps-dme1132piso-13849-1c300 PDF

    Contextual Info: Product data sheet Characteristics XPSMC32ZC safety controller XPS-MC - 24 V DC - 32 input 48 LEDs signalling Commercial Status Commercialised Range of product Preventa Safety automation Product or component type Configurable safety controller Safety module name


    Original
    xpsmc32zc954-1/en/1760-1/iso574/iso+1954-1/en/iso PDF

    XPS-ASf

    Abstract: XPS-ASF5142 XPS-AS XPS-ASF3442 XPS-Apf xpsasf5142 XPS-ASF3742 Y33-Y34 xps-bc S41-S42
    Contextual Info: Components for safety applications Preventa safety modules for emergency stop, limit switch, two-hand control, safety mat and edge monitoring Operating principle, characteristics Operating principle see page 1/12 1 Characteristics Type XPS-ASF Product designed for use in safety


    Original
    s11-s12s21-s22s11-b1s33-s34+11y33/43xps-asfxps-asf5142xps-asxps-asf3442xps-apfxpsasf5142xps-asf3742y33-y34xps-bcs41-s42 PDF

    EN1050

    Abstract: IEC 947-5-1 VDE 0660 LIMIT SWITCH XPS-FB5111 xps* preventa xps-fb XPSFB3711 Electronic fuse linked state machines electromagnetic lock Y4 S4
    Contextual Info: Components for safety applications Preventa safety modules for electrical monitoring of limit switches combined in pairs Operating principle Operating principle 1 Preventa safety module XPS-FB meets the safety requirements for monitoring the operation of 2 limit switches used on


    Original
    en1050iec 947-5-1 vde 0660 limit switchxps-fb5111xps* preventa+6xps-fbxpsfb3711electronic fuselinked state machineselectromagnetic locky4 s4 PDF