SAE 1752 Search Results
SAE 1752 Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| 51752-038LF | Amphenol Communications Solutions | PwrBlade®, Power Supply Connectors, 8P 16S Vertical Receptacle. | |||
| 51752-004LF | Amphenol Communications Solutions | PwrBlade®, Power Supply Connectors, 14P 28S Vertical Receptacle. | |||
| 51752-035LF | Amphenol Communications Solutions | PwrBlade®, Power Supply Connectors, 8P 36S Vertical Receptacle. | |||
| 51752-037LF | Amphenol Communications Solutions | PwrBlade®, Power Supply Connectors, 4P 24S Vertical Receptacle. | |||
| 51752-013LF | Amphenol Communications Solutions | PwrBlade®, Power Supply Connectors, 14P 32S Vertical Receptacle. |
Documents mentioning SAE 1752
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| map55 | MAP55 SERIES Other mechanical design innovations include metric and SAE mounting inserts on each mounting surface to provide integration flexibility. Dual-mode connectors provide traditional terminal block connections or popular single row Molex connector mating. |
Original | ||||
| MAP55 SERIES Other mechanical design innovations | MAP55 SERIES Other mechanical design innovations include metric and SAE mounting inserts on each mounting surface to provide integration flexibility. Dual-mode connectors provide traditional terminal block connections or popular single row Molex connector mating. |
Original | ||||
| 502-1212 Engineering Report 02Nov06 Rev A | 502-1212 Engineering Report 02Nov06 Rev A Evaluation of .040/2.8 mm Contact Systems 1. INTRODUCTION 1.1. Purpose Testing was performed on the Tyco Electronics .040 and 2.8 mm Contact Systems to determine their performance when subjected to selected tests of SAE/USCAR (see Figure 2). |
Original | ||||
| APPLICATION NOTE EMC GUIDE-LINES FOR | APPLICATION NOTE EMC GUIDE-LINES FOR MICROCONTROLLER - BASED APPLICATIONS By Edouard PRESSON and David JACQUINOD INTRODUCTION EMC must be taken into account at the very beginning of a project; the cost of correcting an EMC problem of an application encountered at the start of the production |
Original | ||||
| APPLICATION NOTE EMC GUIDE-LINES FOR | APPLICATION NOTE EMC GUIDE-LINES FOR MICROCONTROLLER - BASED APPLICATIONS By Edouard PRESSON and David JACQUINOD INTRODUCTION EMC must be taken into account at the very beginning of a project; the cost of correcting an EMC problem of an application encountered at the start of the production |
Original | ||||
| an901 | AN901 APPLICATION NOTE EMC GUIDELINES FOR MICROCONTROLLER-BASED APPLICATIONS by Microcontroller Division Applications INTRODUCTION Electromagnetic compatibility (EMC) must be taken into account at the very beginning of a project as the cost of correcting an EMC problem encountered at the start of production can be |
Original | ||||
| an901 | AN901 APPLICATION NOTE EMC GUIDELINES FOR MICROCONTROLLER-BASED APPLICATIONS by Microcontroller Division Applications INTRODUCTION Electromagnetic compatibility (EMC) must be taken into account at the very beginning of a project as the cost of correcting an EMC problem encountered at the start of production can be |
Original | ||||
| APPLICATION NOTE EMC GUIDE-LINES FOR | APPLICATION NOTE EMC GUIDE-LINES FOR MICROCONTROLLER - BASED APPLICATIONS by Edouard PRESSON and David JACQUINOD INTRODUCTION EMC must be taken into account at the very beginning of a project; the cost of correcting an EMC problem of an application encountered at the start of the production can be far greater |
Original | ||||
| tja1040 | $33/,&$7,21 127( 7-$ &$1 +LJK6SHHG 7UDQVFHLYHU $1 3KLOLSV 6HPLFRQGXFWRUV 3KLOLSV 6HPLFRQGXFWRUV 7-$ &$1 +LJK6SHHG 7UDQVFHLYHU $SSOLFDWLRQ 1RWH $1 $EVWUDFW The TJA1040 is an advanced CAN High-Speed Transceiver for use in automotive and general industrial |
Original | ||||
| an247 | INTEGRATED CIRCUITS AN247 PCK2001 (CKBF) reduced EMI techniques Logic Products Group Philips Semiconductors 1998 May 18 Philips Semiconductors Application note PCK2001 (CKBF) reduced EMI techniques Most PC manufactures are required to meet these EMI testing |
Original | ||||
| Instruction Sheet PIDG* STRATO-THERM* Terminal | Instruction Sheet PIDG* STRATO-THERM* Terminal 408-10175 Crimping Heads Used with Heavy Head Battery Powered Hand Tool Kits 1901235-[ ] 05 DEC 07 Rev B Battery Lock Battery Powered Crimp Tool Release Switch (1901235-1 and -2 Only) Quick-Release Pin 217873-4 |
Original | ||||
| Instruction Sheet 408-10040 PIDG* STRATO-THERM* | Instruction Sheet 408-10040 PIDG* STRATO-THERM* Terminal Crimping Tools 04 MAR 09 Rev C PROPER USE GUIDELINES Cumulative Trauma Disorders can result from the prolonged use of manually powered hand tools. Hand tools are intended for occasional use and low volume |
Original | ||||
| map55 | MAP55 AC-DC Series Data Sheet Features Description • RoHS lead-solder-exempt compliant • Wide Range Input for 110/220 VAC Applications • Meets EN55022, Conducted Class B Limits • Compact Footprint: 6.00" x 3.27" x 1.60" (152.4mm x 83.1mm x 40.6mm) |
Original | ||||
| map55 | MAP55 AC/DC Series Data Sheet Features Description • Wide Range Input for 110/220 VAC Applications • Meets EN55022, Conducted Class B Limits • Compact Footprint: 6.00" x 3.27" x 1.60" (152.4mm x 83.1mm x 40.6mm) • Greater than 225,000 Hours MTBF • |
Original | ||||
|
|
||||||
| MAP80 AC-DC Series Data Sheet Features • RoHS | MAP80 AC-DC Series Data Sheet Features • RoHS lead-solder-exemption compliant • Wide-range input for 110/220 VAC applications • CE marked to Low Voltage Directive • Input transient & ESD compliance to EN61000-4-2/-3/-4 • Meets EN55022, Class B limits |
Original | ||||
| map80 | MAP80 AC-DC Series Data Sheet Features • RoHS lead-solder-exempt compliant • Wide-range input for 110/220 VAC applications • CE marked to Low Voltage Directive • Input transient & ESD compliance to EN61000-4-2/-3/-4 • Meets EN55022, Class B limits |
Original | ||||
| map80 | MAP80 AC/DC Series Data Sheet Power-One’s MAP80 Series of power supplies provides reliable, tightly-regulated DC power for commercial and industrial systems which require high peak current capabilities. Wide-range AC input and full international safety, EMI, and ESD compliance ensure worldwide |
Original | ||||
| map80 | MAP80 AC/DC Series Data Sheet Features • Wide-range input for 110/220 VAC applications • CE marked to Low Voltage Directive • Input transient & ESD compliance to EN61000-4-2/-3/-4 • Meets EN55022, Class B limits • TTL compatible Power Fail Signal |
Original | ||||
| map80 | MAP80 SERIES Power-One’s MAP80 series of power supplies provides reliable, tightly regulated DC power for commercial and industrial systems which require high peak current capabilities. Wide-range AC input and full international safety, EMI, and ESD compliance ensure world-wide |
Original | ||||
| map130 | MAP130 AC-DC Series Data Sheet Features • RoHS lead-solder-exemption compliant • Automatic 115/230 input voltage selection All outputs fully regulated Remote sense, overvoltage protection, and overtemperature protection Power Fail signal included |
Original | ||||
| map130 | MAP130 SERIES Power-One’s MAP130 series of single and multiple output power supplies provide fully regulated outputs with high-peak current capabilities in a compact 4.50" x 8.50" x 2.00" U-channel chassis. Other standard features include autoselect AC input, EMI level B |
Original | ||||
| map130 | MAP130 AC-DC Series Data Sheet Features • RoHS lead-solder-exempt compliant • Automatic 115/230 input voltage selection All outputs fully regulated Remote sense, overvoltage protection, and overtemperature protection Power Fail signal included |
Original | ||||
| map130 | MAP130 AC-DC Series Data Sheet Features • Automatic 115/230 input voltage selection All outputs fully regulated Remote sense, overvoltage protection, and overtemperature protection Power Fail signal included Greater than 100,000 Hour MTBF |
Original | ||||
| map130 | MAP130 AC/DC Series Data Sheet Features • Automatic 115/230 input voltage selection All outputs fully regulated Remote sense, overvoltage protection, and overtemperature protection Power Fail signal included Greater than 100,000 Hour MTBF |
Original | ||||