S20 VARISTOR Search Results
Documents mentioning S20 VARISTOR
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| SIOV metal oxide varistors Leaded varistors, | SIOV metal oxide varistors Leaded varistors, SuperioR-MP series Series/Type: S20 Date: December 2007 Data Sheet EPCOS AG 2008. Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without EPCOS’ prior express consent is prohibited. |
Original | ||||
| s14 | Disk Varistors, S Standard Construction • Round varistor element • Coating: epoxy resin, flame-retardant to UL 94 V-0 • Terminals: tinned copper wire New features • New high-energy varistors S14/S20… E2 • PSpice models Approvals • |
OCR Scan | ||||
| Disk Varistors Taping All disk varistors from | Disk Varistors Taping All disk varistors from voltage class M4 through K300 (except type series SIOV-S20) are available on tape. Tape packaging for lead spacing Cell = 5 fully conform s to IEC 286-2, while for lead spacings I 6 \ = 7.5 and 10 the taping mode is based on this standard. |
OCR Scan | ||||
| Overvoltage Transient Suppressors Metal Oxide | Overvoltage Transient Suppressors Metal Oxide Varistors (MOV) Maximum Voltage ECG Type RMS VACM (Volts) DC V dcm (Volts) Clamping VCL (Volts) Nominal Varistor Voltage V nom Volts Energy W tm (Joules) Peak Current Itm (Amps) Transient Power Dissipation Pd (Watts) |
OCR Scan | ||||
| Partnerschaft mit Siemens RS Components bietet | Partnerschaft mit Siemens RS Components bietet durch eine vertiefte Zusammenarbeit mit Siemens Passive Bauelemente und Röhren eine besondere Dienstleistung an: Als offizieller Schwerpunkthändler liefern wir unseren Kunden alle 2 600 Produkte aus dem Siemens Bauteile Service Katalog (SBS-Buch). |
Original | ||||
| Leaded Varistors Automotive Series for 42-V | Leaded Varistors Automotive Series for 42-V Supply Systems Construction ■ Round varistor element, leaded ■ Coating: phenolic resin ■ Terminals: tinned copper wire Features ■ New automotive series for 42-V supply systems ■ This series complies with the electrical requirements for the new |
Original | ||||
| cn0603 | Type Survey SMD varistors Standard Operating voltage VRMS Surge current imax Energy absorption Wmax Automotive Operating voltage VRMS Surge current imax Energy absorption Wmax CN0603 Page 90 ff CN0805 Page 90 ff CN1206 Page 90 ff CN1210 Page 90 ff 4 … 14 V |
Original | ||||
| Disk Varistors Automotive Models General | Disk Varistors Automotive Models General technical data Clim atic category LCT UCT Damp heat, steady state (9 3 % r. h „ 40 "C) 55/85/56 - 5 5 ”C + 85 ’C 56 days in accordance with IEC 68-1 Operating tem perature (full load) - 5 5… + 85 ’C in accordance with CECC 42 000 |
OCR Scan | ||||
| Disk Varistors Construction SR: • Rectangular | Disk Varistors Construction SR: • Rectangular varistor element in m ultilayer technology Coating: epoxy resin, flam e-retardant to UL 94 V-0 Terminals: tinned copper wire Round varistor element Coating: epoxy resin, flam e-retardant to UL 94 V-0 |
OCR Scan | ||||
| US_aussen_BD.qxd 20.12.2007 13:33 Uhr Seite 1 | US_aussen_BD.qxd 20.12.2007 13:33 Uhr Seite 1 EPCOS Data Book 2008 SIOV Metal Oxide Varistors b y E P C O S A G · C o r p o r a t e C e n t e r Edition 11/2007 · Ordering No. EPC:62006-7600 · Printed in Germany · DB 11078. 2008 P u b l i s h e d SIOV Metal Oxide Varistors |
Original | ||||
| Leaded Varistors Automotive Series Construction ■ | Leaded Varistors Automotive Series Construction ■ Round varistor element, leaded ■ Coating: epoxy resin (D1: phenolic resin), flame-retardant to UL 94 V-0 ■ Terminals: tinned copper wire Features ■ High energy absorption, ■ particularly in case of load dump |
Original | ||||
| Application-Specific Varistors 3.1 Autom otive | Application-Specific Varistors 3.1 Autom otive varistors 3.1.1 Requirem ents on autom otive electrical system s Electronic equipm ent must work reliably in its electrom agnetic environm ent without itself unduly in fluencing this environm ent. This requirement, known as electrom agnetic com patibility (EMC), is es |
OCR Scan | ||||
| pm4100apd | PM4100APD Application Note: Energy Meter Evaluation Module sames PM4100APD FEATURES + Compatible with SA4102A / SA2002E / SA2002H / + SA2002P / SA2002D / SA2102D. All devices are PDIP20, Connection of external sensing elements, mains and Operation from either single +5V supply or dual rail supply |
Original | ||||
| Switching Solutions Teledyne Relays has been | Switching Solutions Teledyne Relays has been providing industrial power solid-state relays for over 40 years. The company offers a broad range of products, from standard off-the-shelf single-, dual-, three- and quad-output relays to custom products with diagnostics and phase monitoring. These |
Original | ||||
|
|
||||||
| SIOV metal oxide varistors Leaded varistors, | SIOV metal oxide varistors Leaded varistors, Automotive 42 V series Series/Type: B722* Date: April 2011 © EPCOS AG 2011. Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited. |
Original | ||||
| Contents Type Survey Page 5 8 General Technical | Contents Type Survey Page 5 8 General Technical Information 11 Application and Selection 29 Application-Specific Varistors 49 Quality 55 SMD Varistors 65 Disk Varistors 85 Block Varistors, Strap Varistors 145 153 Arrester Blocks 169 Siemens Matsushita Components |
Original | ||||
| SIOV metal oxide varistors Leaded varistors, | SIOV metal oxide varistors Leaded varistors, StandarD series Series/Type: B722* Date: April 2011 © EPCOS AG 2011. Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited. |
Original | ||||
| Produktübersicht Überspannungsschutz EGU 1 - | Produktübersicht Überspannungsschutz EGU 1 - Zweistufig, ein Strompfad Seite 6-11/6 EGU 4 - Dreistufig, zwei Strompfade Seite 6-11/8 TGU - Testkoffer EGU 2 - Dreistufig, ein Strompfad Seite 6-11/6 Seite 6-11/7 RSU - Dreistufig, zwei Strompfade LPU - Steckbar, dreistufig, zwei Strompfade |
Original | ||||
| b722 | SIOV metal oxide varistors Leaded varistors, StandarD series Series/Type: B722* Date: April 2011 © EPCOS AG 2011. Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited. |
Original | ||||
| p | Motor Controllers Dynamic Braking Types RTC 40 HD12-./RTO 12.. • Control and output modules for dynamic braking of 3-phase induction motors • Rated operational current: 18.5, 30 and 60 A DC • Rated operational voltage: Up to 400 VACrms • Control voltage: 10 to 32 VDC |
Original | ||||
| SIOV metal oxide varistors Leaded varistors, | SIOV metal oxide varistors Leaded varistors, AdvanceD series Series/Type: B722* Date: April 2011 © EPCOS AG 2011. Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited. |
Original | ||||
| sipart dr21 | SIPART DR21 Controllers Page Siemens MP 31 · Supplement September 1999 Description Application, design Mode of operation Control and display functions Configuring switches, OnĆlineĆ/offĆline parameter 5/2 5/2 5/3 5/8 Technical data 5/12 Ordering data 5/14 |
Original | ||||
| 3 Application and design examples 3.1 Switching | 3 Application and design examples 3.1 Switching off inductive loads The discharge of an inductor produces high voltages that endanger both the contact breaker (switching transistor and the like) and the inductor itself. According to equation 16 the energy stored |
Original | ||||
| Overvoltage Protection 234 Overvoltage Protection | Overvoltage Protection 234 Overvoltage Protection Overvoltage Protection The electronic equipping of electrical installations is becoming increasingly complex. PLC controls and PC applications are replacing hard-wired relay technology. Interferences from overvoltage or switching |
Original | ||||
| SIPART DR19 Controllers Page Siemens MP 31 · | SIPART DR19 Controllers Page Siemens MP 31 · Supplement July 1999 Description Application, design Mode of operation Function diagram Operating and display functions Configuring switches, onĆlineĆ/offĆline parameters 3/2 3/2 3/3 3/9 3/10 Technical data |
Original | ||||