Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    RTXP 18 CUTOUT Search Results

    RTXP 18 CUTOUT Result Highlights (4)

    Part ECAD Model Manufacturer Description Download Buy
    HM2P77PD5111N9LF
    Amphenol Communications Solutions Back Plane Connectors, 2mm Hard Metric Series Millipacs, Vertical Header, Type B8 with 3 cutouts for coding, 40 Signal Pin, Press Fit Tail,Shielded, 250 mating cycles,ROHS Compliant PDF
    HM2P78PD5111N9LF
    Amphenol Communications Solutions Back Plane Connectors, 2mm Hard Metric Series Millipacs, Vertical Header, Type B8 with 2 cutouts for coding, 40 Signal Pin, Press Fit Tail,Shielded, 250 mating cycles,ROHS Compliant PDF
    HM2P79PD5111N9LF
    Amphenol Communications Solutions Back Plane Connectors, 2mm Hard Metric Series Millipacs, Vertical Header, Type B8 with 1 cutouts for coding, 40 Signal Pin, Press Fit Tail,Shielded, 250 mating cycles,ROHS Compliant PDF
    HM2P78PDS341N9LF
    Amphenol Communications Solutions Back Plane Connectors, 2mm Hard Metric Series Millipacs, Vertical Header, Type B8 with 2 cutouts for coding, 40 Signal Pin, Press Fit Tail,Shielded, 250 mating cycles,ROHS Compliant PDF

    Documents mentioning RTXP 18 CUTOUT

    Document Partial File Text Tags Type PDF
    combiflex
    Connection and installation components COMBIFLEX 1MRK 513 003-BEN Page 1 Issued May 2007 Revision: C Data subject to change without notice (xx04000071.jpg) (xx04000070.jpg) Features • Easy, flexible and rapid installation, service and expansion of both simple and complex
    Original PDF
    Control terminal REC 561*2.0 1MRK 606 009-BEN
    Control terminal REC 561*2.0 1MRK 606 009-BEN Page 1 Issued May 2002 Changed since October 1999 Data subject to change without notice (SE 95 02 22) Features • Control functionality for; - single, double and triple busbar arrangements - double breaker arrangements
    Original PDF
    rel 511
    REL 511 C*2.0 1 MAK 506 024-BEN Page 1 Issued Apri/1999 Status: New Data subjecllo change withoui nolice (SE 95 02 07) Features .Line distance functionality comprises; -simultaneous measurement of the different phase. phase and phase. earth impedances with numerical measuring
    Original PDF
    reb 551
    Breaker protection terminal REB 551*2.0 1MRK 606 008-BEN Page 1 Issued May 2002 Changed since October 1998 Data subject to change without notice (SE 95 02 14) Features • Protection functionality such as; - breaker failure protection - pole discordance protection
    Original PDF
    rel 551
    Line differential protection terminal REL 551*2.0 1MRK 606 006-BEN Page 1 Issued May 2002 Changed since October 1998 Data subject to change without notice (SE 95 02 13) Features • Line differential functionality comprises; - phase segregated current differential
    Original PDF
    Line distance protection IED REL 670 Buyer's
    Line distance protection IED REL 670 Buyer's Guide Open Configuration 1MRK 506 237-BEN Revision: G Issued: February 2007 Data subject to change without notice Page 1 Features • A protection, control, and monitoring IED with extensive functional library and configuration
    Original PDF
    rec 670
    Bay control IED REC 670 Buyer's Guide Open Configuration 1MRK 511 154-BEN Revision: G Issued: February 2007 Data subject to change without notice Page 1 Features • A control, protection, and monitoring IED with extensive functional library and configuration
    Original PDF
    rec 670
    Bay control IED REC 670 Buyer's Guide Pre-configured 1MRK 511 176-BEN Revision: H Issued: February 2007 Data subject to change without notice Page 1 Features • Three configuration alternatives for single- or multi-breaker arrangements available – ready to
    Original PDF
    080-ben
    Transformer protection IED RET 670 Buyer's Guide Pre-configured 1MRK 504 080-BEN Revision: G Issued: February 2007 Data subject to change without notice Page 1 Features • Four configuration alternatives for single- or multi-breaker arrangements available – ready to
    Original PDF
    164-ben
    Line differential protection IED RED 670 Buyer's Guide Pre-configured 1MRK 505 164-BEN Revision: G Issued: February 2007 Data subject to change without notice Page 1 Features • Four configuration alternatives for single- or multi-breaker arrangements available – ready to
    Original PDF
    Line differential protection IED RED 670 Buyer's
    Line differential protection IED RED 670 Buyer's Guide Open Configuration 1MRK 505 137-BEN Revision: G Issued: February 2007 Data subject to change without notice Page 1 Features • A protection, control, and monitoring IED with extensive functional library and configuration
    Original PDF
    Type COMBIFLEX 1MDB13003—EN Connection and
    Type COMBIFLEX 1MDB13003—EN Connection and installation components Page 1 March 1992 Changed since August 1990 Data subject to change without notice ABB Network Control & Protection (94540) Features Application Design Technical data •Perm its easy, flexible and rapid installation,
    OCR Scan PDF
    39584 GE Consumer & Industrial Power Protection
    39584 GE Consumer & Industrial Power Protection GE Consumer & Industrial Power Protection (formerly GE Power Controls), a division of GE Consumer & Industrial, is a first class European supplier of low-voltage products including wiring devices, residential and industrial electrical
    Original PDF
    rel 670
    Line distance protection IED REL 670 Buyer's Guide Pre-configured 1MRK 506 264-BEN Revision: G Issued: February 2007 Data subject to change without notice Page 1 Features • Four configuration alternatives for single- or multi-breaker arrangements available – ready to
    Original PDF
    053-ben
    Transformer protection IED RET 670 Buyer's Guide Open Configuration 1MRK 504 053-BEN Revision: G Issued: February 2007 Data subject to change without notice Page 1 Features • A protection, control, and monitoring IED with extensive functional library and configuration
    Original PDF
    Line distance protection terminal REL 501*2.0
    Line distance protection terminal REL 501*2.0 1MRK 606 002-BEN Page 1 Issued May 2002 Changed since October 1998 Data subject to change without notice (SE 95 02 07) Features • Line distance functionality comprises; - simultaneous measurement of the different phase - phase impedances within
    Original PDF
    $XWRPDWLF 5HFORVLQJ 7HUPLQDO 5(% &  1MRK
    $XWRPDWLF 5HFORVLQJ 7HUPLQDO 5(% &  1MRK 505 094-BEN Page 1 Revision: Issued: March 2003 Data subject to change without notice )HDWXUHV • Control - Automatic reclosing function (AR) • Logic - Trip logic (TR) • Serial communication - Simultaneous dual protocol serial communication facilities
    Original PDF
    rel 521
    Line distance protection terminal REL 521*2.0 1MRK 606 004-BEN Page 1 Issued May 2002 Changed since October 1998 Data subject to change without notice (SE 95 02 16) Features • Line distance functionality comprises; - simultaneous measurement of the different phase - phase and phase - earth
    Original PDF
    rel 511
    Line distance protection terminal REL 511*2.0 1MRK 606 003-BEN Page 1 Issued May 2002 Changed since June 1999 Data subject to change without notice (SE 95 02 08) Features • Line distance functionality comprises; - simultaneous measurement of the different phase - phase and phase - earth
    Original PDF
    reb 670
    Busbar differential protection IED REB 670 Buyer's Guide Pre-configured 1MRK 505 172-BEN Revision: A Issued: February 2007 Data subject to change without notice Page 1 Features • IED for differential protection of busbars, meshed corners and T-protection
    Original PDF
    rel 531
    Line distance protection terminal REL 531*2.0 1MRK 606 005-BEN Page 1 May 2002 Changed since October 1998 Data subject to change without notice (SE 95 02 15) Features • Line distance functionality comprises; - simultaneous measurement of the different phase - phase and phase - earth
    Original PDF
    rel 561
    Line differential protection terminal REL 561*2.0 1MRK 606 007-BEN Page 1 Issued May 2002 Changed since October 1998 Data subject to change without notice (SE 95 02 12) Features • Line differential functionality comprises; - phase segregated current differential
    Original PDF
    ASEA Catalogue RK 92-10 E Edition 3 September
    ASEA Catalogue RK 92-10 E Edition 3 September 1980 File R, part 1 Connection and installation parts for COMBIFLEX modular system • Connection parts for up to 10 and 20 A continuous load • Installation parts for construction of apparatus groups and their installation in equipment frames, cases, boxes and
    OCR Scan PDF
    3URWHFW,7 $XWRUHFORVHU WHUPLQDO 5(% & 
    3URWHFW,7 $XWRUHFORVHU WHUPLQDO 5(% &  1MRK 505 103-BEN Page 1 Revision: – Issued: October 2003 Data subject to change without notice )HDWXUHV )XQFWLRQV • Pre-configured protection terminal for costeffective engineering and commissioning • Extensive self-supervision with internal
    Original PDF
    SPAA 120 C and SPAA 121 C Feeder protection relay
    SPAA 120 C and SPAA 121 C Feeder protection relay User´s manual and Technical description B I n = 1A 5A ( I ) I n = 1A 5A ( I o ) U n = 100V 110V ( U o ) f n = 50Hz 60Hz 2I > I 2 I 5 L1 I L3 U o I o IRF SPAA 120 C 80…265V – ~ 18…80V – I >/I n U aux
    Original PDF