RTD IC Search Results
RTD IC Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| TA75W393FU | Toshiba Electronic Devices & Storage Corporation | Comparator, Bipolar (393) type Dual Comparator, 2V to 36V, SOT-25 | Datasheet | ||
| TC75S59F | Toshiba Electronic Devices & Storage Corporation | Comparator, 1.8V to 7.0V, IDD=100μA, Open-drain output, SOT-25/SOT-353 | Datasheet | ||
| TA75S393F | Toshiba Electronic Devices & Storage Corporation | Comparator, Bipolar (393) type, 2V to 36V, SOT-25 | Datasheet | ||
| TC75S58F | Toshiba Electronic Devices & Storage Corporation | Comparator, 1.8V to 7.0V, IDD=10μA, Open-drain output, SOT-25/SOT-353 | Datasheet | ||
| TC75S70L6X | Toshiba Electronic Devices & Storage Corporation | Comparator, 1.3V to 5.5V, IDD=18μA, MP6C(1.0x1.45mm) | Datasheet |
Documents mentioning RTD IC
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| cfp-tc-120 | Thermocouple and RTD Modules for Compact FieldPoint NI cFP-TC-120, NI cFP-TC-125, NI cFP-RTD-122, NI cFP-RTD-124 • 8 temperature inputs • Thermocouple or millivolt • 2-, 3-, or 4-wire RTD • Built-in signal conditioning between channels • 250 V common-mode isolation |
Original | ||||
| xtr105 | ® FOUR-WIRE RTD CURRENT-LOOP TRANSMITTER: Four-Wire Connections to an RTD Allow the RTD to be Remotely Located from Active Circuitry, Yet Maintain Accuracy by David Jones, and Mark Stitt XTR105 is an application-specific IC containing onboard transducer excitation, signal conditioning instrumentation |
Original | ||||
| xtr105 | ® FOUR-WIRE RTD CURRENT-LOOP TRANSMITTER: Four-Wire Connections to an RTD Allow the RTD to be Remotely Located from Active Circuitry, Yet Maintain Accuracy by David Jones, and Mark Stitt XTR105 is an application-specific IC containing onboard transducer excitation, signal conditioning instrumentation |
Original | ||||
| max6603 | 19-3975; Rev 0; 4/06 Dual-Channel, Platinum RTD-to-Voltage Signal Conditioner The MAX6603 dual-channel, platinum RTD-to-voltage signal conditioner excites and amplifies the signal from two external 200Ω platinum-resistive temperature devices (Pt RTD) to achieve high-voltage, level-filtered |
Original | ||||
| For Immediate Issislm e, Contici Your Local | For Immediate Issislm e, Contici Your Local Salesperson XTR103 4-20mA Current Transmitter with RTD EXCITATION AND LINEARIZATION FEATURES APPLICATIONS • LESS THAN ±1% TOTAL ADJUSTED ERROR, -40°C TO +85°C • RTD EXCITATION AND LINEARIZATION • TWO OR THREE-WIRE RTD OPERATION |
OCR Scan | ||||
| an1154 | AN1154 Precision RTD Instrumentation for Temperature Sensing SOLUTION Ezana Haile Microchip Technology Inc. This solution uses a common reference voltage to bias the RTD and the ADC which provides a ratio-metric relation between the ADC resolution and the RTD temperature resolution. Only one biasing resistor, RA, is |
Original | ||||
| platinum resistance temperature detector | Thin Film Platinum Resistance Temperature Detector 31 Introduction The thin film Platinum Resistance Temperature Detector (Pt-RTD) consists of thin film deposited Platinum with extending in expensive metal wire (e.g. Palladium). Thin film Pt-RTD provides dramatic cost advantage compared to conventional wire wound Pt-RTD while with the same |
Original | ||||
| an895 | AN895 Oscillator Circuits For RTD Temperature Sensors Author: RTDs serve as the standard for precision temperature measurements because of their excellent repeatability and stability characteristics. A RTD can be characterized over it’s temperature measurement range to |
Original | ||||
| ANALOG DEVICES Linearized 4-Wire RTD I nput | ANALOG DEVICES Linearized 4-Wire RTD I nput Module MODEL5B35 FEATURES Accepts a Variety of RTD Types 100 i l Platinum, 10 i l Copper, 120 i l Nickel Linearizes RTD Signal 1500 V rms In p u t/O u tp ut and In p u t/P o w er Isolation 250 V rms O u tp u t/P o w er Isolation |
OCR Scan | ||||
| Isolated RTD Signal Conditioner ANALOG ► DEVICES | Isolated RTD Signal Conditioner ANALOG ► DEVICES FUNCTIONAL BLOCK DIAGRAM FEATURES Complete RTD Signal Conditioning Solution Resistor Programmable Linearization Lead Resistance Compensation High CMV Isolation: 1500 V rms Continuous High Accuracy Low Input Offset Tempco: 0.002 il/°C |
OCR Scan | ||||
| xtr103 | ® XTR103 4-20mA Current Transmitter with RTD EXCITATION AND LINEARIZATION FEATURES APPLICATIONS ● LESS THAN ±1% TOTAL ADJUSTED ERROR, –40°C TO +85°C ● RTD EXCITATION AND LINEARIZATION ● INDUSTRIAL PROCESS CONTROL ● FACTORY AUTOMATION ● SCADA |
Original | ||||
| ® XTR103 4-20mA Current Transmitter with RTD | ® XTR103 4-20mA Current Transmitter with RTD EXCITATION AND LINEARIZATION FEATURES APPLICATIONS ● LESS THAN ±1% TOTAL ADJUSTED ERROR, –40°C TO +85°C ● RTD EXCITATION AND LINEARIZATION ● INDUSTRIAL PROCESS CONTROL ● FACTORY AUTOMATION ● SCADA |
Original | ||||
| ANALOG ► DEVICES Isolated RTD Signal Conditioner | ANALOG ► DEVICES Isolated RTD Signal Conditioner FUNCTIONAL BLOCK DIAGRAM FEATURES Complete RTD Signal Conditioning Solution Resistor Programmable Linearization Lead Resistance Compensation High CMV Isolation: 1500 V rms Continuous High Accuracy Low Input Offset Tempco: 0.002 il/°C |
OCR Scan | ||||
| xtr103 | ® XTR103 XTR 103 XTR 103 4-20mA Current Transmitter with RTD EXCITATION AND LINEARIZATION FEATURES APPLICATIONS ● LESS THAN ±1% TOTAL ADJUSTED ERROR, –40°C TO +85°C ● RTD EXCITATION AND LINEARIZATION ● INDUSTRIAL PROCESS CONTROL ● FACTORY AUTOMATION |
Original | ||||
|
|
||||||
| xtr103 | ® XTR103 XTR 103 XTR 103 4-20mA Current Transmitter with RTD EXCITATION AND LINEARIZATION FEATURES APPLICATIONS ● LESS THAN ±1% TOTAL ADJUSTED ERROR, –40°C TO +85°C ● RTD EXCITATION AND LINEARIZATION ● INDUSTRIAL PROCESS CONTROL ● FACTORY AUTOMATION |
Original | ||||
| xtr103 | ® XTR103 XTR 103 XTR 103 4-20mA Current Transmitter with RTD EXCITATION AND LINEARIZATION FEATURES APPLICATIONS ● LESS THAN ±1% TOTAL ADJUSTED ERROR, –40°C TO +85°C ● RTD EXCITATION AND LINEARIZATION ● INDUSTRIAL PROCESS CONTROL ● FACTORY AUTOMATION |
Original | ||||
| xtr103 | ® XTR103 4-20mA Current Transmitter with RTD EXCITATION AND LINEARIZATION FEATURES APPLICATIONS ● LESS THAN ±1% TOTAL ADJUSTED ERROR, –40°C TO +85°C ● RTD EXCITATION AND LINEARIZATION ● INDUSTRIAL PROCESS CONTROL ● FACTORY AUTOMATION ● SCADA |
Original | ||||
| 1b41 | A N A LO G DEVICES Isolated RTD Signal Conditioner 1B41 FEATURES Complete RTD Signal Conditioning Solution Resistor Programmable Linearization Lead Resistance Compensation High CMV Isolation: 1500 V rms Continuous High Accuracy Low Input Offset Tempco: 0.002 fi/°C |
OCR Scan | ||||
| THE THERMISTOR 12 .390 .344 .293 8 Equivalent | THE THERMISTOR 12 .390 .344 .293 8 Equivalent Linearities Type S Thermocouple vs. Platinum RTD 4 200 400 600 Like the RTD, the thermistor is also a temperature sensitive resistor. While the thermocouple is the most versatile temperature transducer and the PRTD is the |
Original | ||||
| EVALUATION KIT AVAILABLE MAX6603 Dual-Channel, | EVALUATION KIT AVAILABLE MAX6603 Dual-Channel, Platinum RTD-to-Voltage Signal Conditioner LE AVAILAB General Description The MAX6603 dual-channel, platinum RTD-to-voltage signal conditioner excites and amplifies the signal from two external 200Ω platinum-resistive temperature |
Original | ||||
| xtr103 | ® XTR103 XTR 103 XTR 103 4-20mA Current Transmitter with RTD EXCITATION AND LINEARIZATION FEATURES APPLICATIONS ● LESS THAN ±1% TOTAL ADJUSTED ERROR, –40°C TO +85°C ● RTD EXCITATION AND LINEARIZATION ● INDUSTRIAL PROCESS CONTROL ● FACTORY AUTOMATION |
Original | ||||