Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    RS&BUS PROTOCOL Search Results

    RS&BUS PROTOCOL Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    CS-USB3.1TYPC-000.5M
    Amphenol Cables on Demand Amphenol CS-USB3.1TYPC-000.5M Amphenol Premium USB 3.1 Gen2 Certified USB Type A-C Cable - USB 3.0 Type A Male to Type C Male [10.0 Gbps SuperSpeed] 0.5m (1.6ft) PDF
    CS-USBAB003.0-003
    Amphenol Cables on Demand Amphenol CS-USBAB003.0-003 Amphenol Premium USB 3.0/3.1 Gen1 Certified USB Type A-B Cable - USB 3.0 Type A Male to Type B Male [5.0 Gbps SuperSpeed] 3m (9.8') PDF
    CS-USBAB003.0-002
    Amphenol Cables on Demand Amphenol CS-USBAB003.0-002 Amphenol Premium USB 3.0/3.1 Gen1 Certified USB Type A-B Cable - USB 3.0 Type A Male to Type B Male [5.0 Gbps SuperSpeed] 2m (6.6') PDF
    CS-USB3.1TYPC-001M
    Amphenol Cables on Demand Amphenol CS-USB3.1TYPC-001M Amphenol Premium USB 3.1 Gen2 Certified USB Type A-C Cable - USB 3.0 Type A Male to Type C Male [10.0 Gbps SuperSpeed] 1m (3.3ft) PDF
    CS-USBAM003.0-001
    Amphenol Cables on Demand Amphenol CS-USBAM003.0-001 Amphenol Premium USB 3.0/3.1 Gen1 Certified USB Type A-A Cable - USB 3.0 Type A Male to Type A Male [5.0 Gbps SuperSpeed] 1m (3.3') PDF

    Documents mentioning RS&BUS PROTOCOL

    Document Partial File Text Tags Type PDF
    ISL81334, ISL41334 ® Data Sheet May 31, 2007
    ISL81334, ISL41334 ® Data Sheet May 31, 2007 ±15kV ESD Protected, 5v, Two Port, Dual Protocol (RS-232/RS-485) Transceivers FN6202.2 Features • ±15kV (HBM) ESD Protected Bus Pins (RS-232 or RS-485) The ISLX1334 are two port interface ICs where each port
    Original PDF
    Media Converter for Bus Systems RS 422
    Media Converter for Bus Systems RS 422 Identification Part No. Media Converter RS 422 Drawing Dimensions in mm The devices provide a mode selection for bus-applications (repeater). full duplex 4 wire transmission Serial Interfaces External power supply: 9… 30 V DC
    Original PDF
    RS-232/UART Triggering and Hardware-Based Decode
    RS-232/UART Triggering and Hardware-Based Decode (N5457A) for Agilent InfiniiVision Oscilloscopes Data Sheet Find and debug intermittent errors and signal integrity problems faster Features: • RS-232/UART serial bus triggering • RS-232/UART hardware-based
    Original PDF
    RS-232/UART Triggering and Hardware-Based Decode
    RS-232/UART Triggering and Hardware-Based Decode (N5457A) for Agilent InfiniiVision Oscilloscopes Data Sheet Find and debug intermittent errors and signal integrity problems faster Features: • RS-232/UART serial bus triggering • RS-232/UART hardware-based
    Original PDF
    isl81334
    ISL81334, ISL41334 ® Data Sheet December 20, 2005 ±15kV ESD Protected, Two Port, Dual Protocol Transceivers FN6202.1 Features • ±15kV (HBM) ESD Protected Bus Pins (RS-232 or RS-485) The ISLX1334 are two port interface ICs where each port can be independently configured as a single RS-485/422
    Original PDF
    FO T-Coupler, PSM-EG-RS-485W2/FO-T/K FO
    FO T-Coupler, PSM-EG-RS-485W2/FO-T/K FO Peripheral device, PSM-EG-RS-485W2/FO-E/K Optic fiber converter (Polymer/HCSfiber) for RS-485 2-wire bus systems 1. Short Description The PSM-EG-RS485W2/FO interface converters convert two-wire RS-485 interfaces which support the
    Original PDF
    USB6Bx  Application Specific Discretes A.S.D.
    USB6Bx  Application Specific Discretes A.S.D. DATA LINES PROTECTION APPLICATIONS Where transient overvoltage protectionin sensitive equipment is required, such as: - Universal Serial Bus ports - RS-423 interfaces - RS-485 interfaces - ISDN equipment
    Original PDF
    usb6b1
    USB6B1 ® Application Specific Discretes A.S.D.™ DATA LINES PROTECTION APPLICATIONS Where transient overvoltage protection in sensitive equipment is required, such as: - Universal Serial Bus ports - RS-423 interfaces - RS-485 interfaces - ISDN equipment
    Original PDF
    sp3481
    +3.3V Low Power RS-485/RS-422 Line Receivers/Tranceivers SP3481/SP3485 +3.3V Low Power Half-Duplex RS-485 Transceivers • Driver/Receiver Enable • Low Power Shutdown Mode (SP3481) • Allows up to 32 transceivers on the serial bus • Compatibility with the industry standard 75176 pinout
    Original PDF
    rs-423
    USB6Bx  Application Specific Discretes A.S.D. DATA LINES PROTECTION APPLICATIONS Where transient overvoltage protection in sensitive equipment is required, such as: - Universal Serial Bus ports - RS-423 interfaces - RS-485 interfaces - ISDN equipment - T1/E1 line cards
    Original PDF
    rs-423
    USB6Bx ® Application Specific Discretes A.S.D. DATA LINES PROTECTION APPLICATIONS Where transient overvoltage protection in sensitive equipment is required, such as: - Universal Serial Bus ports - RS-423 interfaces - RS-485 interfaces - ISDN equipment - T1/E1 line cards
    Original PDF
    usb6b1
    USB6B1 ® IPAD™ DATA LINES PROTECTION APPLICATIONS Where transient overvoltage protection in sensitive equipment is required, such as: - Universal Serial Bus ports - RS-423 interfaces - RS-485 interfaces - ISDN equipment - T1/E1 line cards - HDSL / ASDL interfaces
    Original PDF
    usb6b1
    USB6B1 ® IPAD™ DATA LINES PROTECTION APPLICATIONS Where transient overvoltage protection in sensitive equipment is required, such as: - Universal Serial Bus ports - RS-423 interfaces - RS-485 interfaces - ISDN equipment - T1/E1 line cards - HDSL / ASDL interfaces
    Original PDF
    usb6b1
    USB6B1 Data line protection Applications Where transient overvoltage protection in sensitive equipment is required, such as: ■ Universal Serial Bus ports ■ RS-423 interfaces ■ RS-485 interfaces ■ ISDN equipment ■ T1/E1 line cards ■ HDSL / ASDL interfaces
    Original PDF
    USB6B1 Data line protection Applications Where
    USB6B1 Data line protection Applications Where transient overvoltage protection in sensitive equipment is required, such as: ■ Universal Serial Bus ports ■ RS-423 interfaces ■ RS-485 interfaces ■ ISDN equipment ■ T1/E1 line cards ■ HDSL / ASDL interfaces
    Original PDF
    64001.qxd 2/3/04 11:06 AM Z-fold Page 1 Z-fold R
    64001.qxd 2/3/04 11:06 AM Z-fold Page 1 Z-fold R E A L Selecting a Standard Infotainment Safety and security Powertrain ⇒ LVDS, CAN CAN, RS-422, LVDS, 1394 CAN Portable Non-portable ⇒ USB, RS-232, 1394, LVDS USB, LVDS, RS-232 Field bus Motor/motion control
    Original PDF
    SP3494 +3.3V Low Power RS-485/RS-422 Transceiver
    SP3494 +3.3V Low Power RS-485/RS-422 Transceiver • Operates From A Single +3.3V Supply • Interoperable With +5.0V Logic • +/-200mV Receiver Input Sensitivity • -7V to +12V Common-Mode Input Voltage Range • Allows Up To 32 transceivers On The Serial Bus
    Original PDF
    OPERATING UNIT 160x104 with touch panel Issue
    OPERATING UNIT 160x104 with touch panel Issue 01-2014 Dimension: 81.5x67.5x13.6mm EA eDIP160W-7LWTP TECHNICAL DATA EA eDIP160B-7LWTP * * * * * * * * LCD-GRAPHIC DISPLAY WITH A RANGE OF GRAPHIC FUNCTIONS 3 DIFFERENT INTERFACES ONBOARD: RS-232, I²C-BUS OR SPI-BUS
    Original PDF
    dvppf02-h2
    注意事項 Connecting to PROFIBUS DP Connector Specifications Insert the PROFIBUS DP bus connector into Interface DB9 connector Transmission method High-speed RS-485 Transmission cable Shielded twisted pair cable DVPPF02-H2 and the PROFIBUS DP bus Electrical isolation
    Original PDF
    OPERATING UNIT 128x64 with touch panel Issue
    OPERATING UNIT 128x64 with touch panel Issue 01-2014 Dimension: 71.4x54.4x13.6mm EA eDIP128B-6LWTP EA eDIP128W-6LWTP TECHNICAL DATA * * * * * * * * * * * * * * * * * * LCD-GRAPHIC DISPLAY WITH A RANGE OF GRAPHIC FUNCTIONS 3 DIFFERENT INTERFACES ONBOARD: RS-232, I²C-BUS OR SPI-BUS
    Original PDF
    uda1331h
    Philips S em ico n d u c to rs P relim in ary sp ecification Universal Serial Bus (USB) Audio Playback Peripheral (APP) _ _ ^ UDA1331H a H W Z F *" BUS UNIVERSAL SERIAL BUS FEATURES D o cu m ent referen ces G en eral • “USB S p e cifica tio n " • U niversal Serial Bus (USB) stereo A udio Playback
    OCR Scan PDF