Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    REVERSE POWER RELAY Search Results

    REVERSE POWER RELAY Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    CO-058SMAMFRP-015
    Amphenol Cables on Demand Amphenol CO-058SMAMFRP-015 Reverse Polarity SMA (RP-SMA) Male to RP-SMA Female Extension Cable (RG58) 50 Ohm Coaxial Cable Assembly 15 ft PDF
    CO-058SMARPTN-015
    Amphenol Cables on Demand Amphenol CO-058SMARPTN-015 Reverse Polarity SMA (RP-SMA) Male to Type N Male (RG58) 50 Ohm Coaxial Cable Assembly 15 ft PDF
    CO-058TNCMFRP-006
    Amphenol Cables on Demand Amphenol CO-058TNCMFRP-006 Reverse Polarity TNC (RP-TNC) Male to RP-TNC Female Extension Cable (RG58) 50 Ohm Coaxial Cable Assembly 6 ft PDF
    CO-058SMAMFRP-010
    Amphenol Cables on Demand Amphenol CO-058SMAMFRP-010 Reverse Polarity SMA (RP-SMA) Male to RP-SMA Female Extension Cable (RG58) 50 Ohm Coaxial Cable Assembly 10 ft PDF
    CO-058SMARPTN-010
    Amphenol Cables on Demand Amphenol CO-058SMARPTN-010 Reverse Polarity SMA (RP-SMA) Male to Type N Male (RG58) 50 Ohm Coaxial Cable Assembly 10 ft PDF

    Documents mentioning REVERSE POWER RELAY

    Document Partial File Text Tags Type PDF
    reverse power relays
    Reverse Power Relays WILMAR™ Protective Relays – 700 Series Function: 32 • ANSI/IEEE C37.90-1978 TERMINAL STRIPS #6 - 32 SCREWS • UL file No. E58048 • CSA file No. LR61158 Several types of Reverse Power Relays are available including relays sensitive to reverse reactive power
    Original PDF
    reverse power relay
    Protection Relays Generator Protection–Reverse Power T2000 Series Reverse Power Relay Description Under parallel operation, the T2000 Reverse Power Relay will protect the generator from being run as an electric motor. The T2000 will protect the prime mover of the generator against
    Original PDF
    reverse power relay
    ABB ASEA BROWN BOVERI Reverse power relay for generators (RXPE 40) B03-4022E Page 1 January 1989 Data subject to change without noticc ABB Relays (830077) Abstract Application ■Single-phase reverse power relay measuring the active component of the generator current
    OCR Scan PDF
    reverse power relays
    Reverse Power Relays WILMAR™ Protective Relays – 700 Series w/ Adjustable Time Delay Function: 32 • ANSI/IEEE C37.90-1978 • UL file No. E58048 • CSA file No. LR61158 TERMINAL STRIPS #6 - 32 SCREWS 3.0 Several types of Reverse Power Relays are available
    Original PDF
    magnetic contactor
    Reverse Protection Relay APR-S Uses Voltage Detection to Determine Reverse Revolution of Three-phase Motor • Detects motor reversal due to incorrect wiring. • Direction of motor revolution is detected as soon as power is applied to the Relay. If the power is reversed, the magnetic contactor locks in the open state.
    Original PDF
    6510
    Preliminary Data PROFET® BTS 6510 Smart Highside High Current Power Switch Reverse Save • Reverse battery protection by self turn on of power MOSFET Features • Overload protection • Current limitation • Short circuit protection • Overtemperature protection
    Original PDF
    contactor
    Reverse Protection Relay APR-S CSM_APR-S_DS_E_2_1 Uses Voltage Detection to Determine Reverse Revolution of Three-phase Motor • Detects motor reversal due to incorrect wiring. • Direction of motor revolution is detected as soon as power is applied to the Relay. If the power is reversed, the magnetic contactor locks in the open state.
    Original PDF
    magnetic contactor
    Reverse Protection Relay APR-S CSM_APR-S_DS_E_2_1 Uses Voltage Detection to Determine Reverse Revolution of Three-phase Motor • Detects motor reversal due to incorrect wiring. • Direction of motor revolution is detected as soon as power is applied to the Relay. If the power is reversed, the magnetic contactor locks in the open state.
    Original PDF
    2sc5576
    2SC5576 Transisitors______________________________________________________ Medium Power Transistor (Motor or Relay drive) (60±10V, 4A) 2SC5576 •Features 1) Built-in zener diode between collector and base. 2) Strong protection against reverse power surges due to
    OCR Scan PDF
    Catalogue ¡ a g s i f f ï K51*1 E L • n*i o l
    Catalogue ¡ a g s i f f ï K51*1 E L • n*i o l POWER RELAYS types RPB, RP 1 and RPF For directional earth-fault protections directional short-circuit protections directional power protections reverse power protections ovef-power and under-power protections
    OCR Scan PDF
    2sd2170
    2SD2170 Transistors______________________________________ Medium Power Transistor (Motor, Relay drive) (903, 2A) 2SD2170 •Features 1) Built-in zener diode between collector and base. 2) Zener diode has low dispersion. 3) Strong protection against reverse power surges due to
    OCR Scan PDF
    reverse power relay
    Protection Relays Generator Protection–Power G2000 Series Power Relay Description The G2000 Power Relay is intended for detection of power level for protection, control and monitoring purposes. In the default configuration, the G2000 acts as a reverse power relay for protection of generators running in parallel.
    Original PDF
    bts550p
    PROFET® Data Sheet BTS550P Smart Highside High Current Power Switch Reverse Save Product Summary Overvoltage protection Output clamp Operating voltage On-state resistance Load current (ISO) Short circuit current limitation Current sense ratio • Reverse battery protection by self turn on of
    Original PDF
    PhotoMOS RELAYS POWER PhotoMOS RELAYS with
    PhotoMOS RELAYS POWER PhotoMOS RELAYS with Internal Varistor FEATURES 1. Power PhotoMOS relay with internal varistor An internal varistor on the output side protects the output MOSFET from the reverse voltage from an external voltage surge or inductive load.
    Original PDF
    PhotoMOS RELAYS POWER PhotoMOS RELAYS with
    PhotoMOS RELAYS POWER PhotoMOS RELAYS with Internal Varistor FEATURES 1. Power PhotoMOS relay with internal varistor An internal varistor on the output side protects the output MOSFET from the reverse voltage from an external voltage surge or inductive load.
    Original PDF