Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    RELAY 230V DC Search Results

    RELAY 230V DC Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    UHD508R/883C
    Rochester Electronics LLC UHD508 - Quad 2-Input NAND Power/Relay Driver. Dual marked (8550001CA) PDF Buy
    MGN1D120603MC-R7
    Murata Manufacturing Co Ltd DC-DC 1W SM 12-6/-3V GAN PDF
    MGN1D050603MC-R7
    Murata Manufacturing Co Ltd DC-DC 1W SM 5-6/-3V GAN PDF
    MGN1S0512MC-R7
    Murata Manufacturing Co Ltd DC-DC 1W SM 5-12V GAN PDF
    MGN1S1212MC-R7
    Murata Manufacturing Co Ltd DC-DC 1W SM 12-12V GAN PDF

    RELAY 230V DC Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    EARTH LEAKAGE RELAY

    Abstract: relay contactor wiring diagrams IEC364 wiring shunt trip IEC755 230V ac relay shunt trip breaker VDE664 AC11 DC11
    Contextual Info: 296-2360 Earth Leakage Relay with Transformer Connection & Test Check the Auxiliary Voltage on the Relay label and connect it as shown on one of the wiring diagrams adjacent 230V Phase and neutral shown ensuring that the supply cables pass through the 35mm aperture in the relay.


    Original
    100mA 300mA 500mA IEC364; IEC755; UTE60 VDE664; NFC61-141( EARTH LEAKAGE RELAY relay contactor wiring diagrams IEC364 wiring shunt trip IEC755 230V ac relay shunt trip breaker VDE664 AC11 DC11 PDF

    IEC 60947-5-6

    Abstract: EX1 RELAY we77 relay 230v 230V ac relay atex 2065 signal relay pulse transformer circuit KFA6-SR2
    Contextual Info: WE 77/Ex-1 230V Switch Amplifier Successor KFA6-SR2-Ex1.W Connection • • • • • • 1-channel Control circuit EEx ia IIC 230 V AC supply voltage Reversible mode of operation Lead breakage LB monitoring 1 relay output with 1 changeover contact WE 77/Ex-1 230V


    Original
    77/Ex-1 IEC 60947-5-6 EX1 RELAY we77 relay 230v 230V ac relay atex 2065 signal relay pulse transformer circuit KFA6-SR2 PDF

    wiring shunt trip

    Abstract: EARTH LEAKAGE RELAY time delay relay 230V shunt trip manual relay relay 230V DC shunt trip breaker AC11 DC11 230V ac relay
    Contextual Info: 267-5729 Earth Leakage Relay Connection & Test Check the Auxiliary Voltage on the Relay label. Depending on the Core Balance C/T type chosen connect as shown on one of the wiring diagrams adjacent 230V Phase and neutral shown .Pass the mains cables through the C/T.


    Original
    300mA RGF10RS wiring shunt trip EARTH LEAKAGE RELAY time delay relay 230V shunt trip manual relay relay 230V DC shunt trip breaker AC11 DC11 230V ac relay PDF

    Contextual Info: 6ES7322-5HF00-0AB0 Page 1 Product data sheet 6ES7322-5HF00-0AB0 SIMATIC S7-300, DIGITAL OUTPUT SM 322, OPTICALLY ISOLATED, 8 DO RELAY , 1 X 40 PIN, 24V DC, 120 - 230V AC, 5A WITH INTEGR. SNUBBER F. IND. LOADS Supply voltage Load voltage L+ Rated value (DC)


    Original
    6ES7322-5HF00-0AB0 S7-300, 40-pin PDF

    Contextual Info: PBDRN120 Series FEATURES • • • • • • • • Input voltage 115/230VAC auto select DC input voltage 210-370Vdc 230V selected Compact and robust design with easy mounting on TS35 Din-Rail DC OK relay contact High efficiency up to 87% Parallel function available (switch)


    Original
    PBDRN120 115/230VAC 210-370Vdc 264VAC 375VDC 115/230VAC, freq000-6-3 25/30ms 20MHz, PDF

    SPA07420

    Abstract: varistor VDR 275 j1kv AC13
    Contextual Info: S/MOD/SPA07420/D/14/05/2002 page 1 / 2 F/GB Relais Statique AC AC Solid State Relay SPA07420 24V AC/DC input 230V/4A AC output • Compatibilité du brochage avec les Relais Electro-mécaniques . • Commande AC et DC Non polarisée. • Sortie AC synchrone.


    Original
    S/MOD/SPA07420/D/14/05/2002 SPA07420 30V/4A 12-275VAC 400VAC 400VAC SPA07420 varistor VDR 275 j1kv AC13 PDF

    varistor VDR 275

    Abstract: ac122 STA07220
    Contextual Info: S/MOD/STA07220/DC/14/05/2002 page 1 / 2 F/GB Relais Statique AC AC Solid State Relay STA07220 24V AC/DC input 230V/2A AC output • Compatibilité du brochage avec les Relais Electro-mécaniques . • Commande AC et DC Non polarisée. • Sortie AC synchrone.


    Original
    S/MOD/STA07220/DC/14/05/2002 STA07220 30V/2A 12-275VAC 400VAC 400VAC varistor VDR 275 ac122 STA07220 PDF

    AC13

    Abstract: AC12 EN60947-5-1 SPA07420
    Contextual Info: S/MOD/SPA07420/C/06/01/2000 page 1 / 2 F/GB Relais Statique AC AC Solid State Relay SPA07420 24V AC/DC input 230V/4A AC output • Compatibilité du brochage avec les Relais Electro-mécaniques . • Commande AC et DC Non polarisée. • Sortie AC synchrone.


    Original
    S/MOD/SPA07420/C/06/01/2000 SPA07420 30V/4A 12-275VAC 400VAC 400VAC AC13 AC12 EN60947-5-1 SPA07420 PDF

    Contextual Info: Data sheet. SSS RELAIS 60V/230V 1AAC Weidmüller Interface GmbH & Co. KG Klingenbergstraße 16 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com TERMSERIES accessories include: • Spare relay • Base • Partition plates


    Original
    0V/230V D-32758 120VAC 60VUC 120VUC 230VAC PDF

    Contextual Info: 6ES7322-1HF01-0AA0 Page 1 Product data sheet 6ES7322-1HF01-0AA0 SIMATIC S7-300, DIGITAL OUTPUT SM 322, OPTICALLY ISOLATED, 8 DO RELAY , 1 X 20 PIN, 24V DC, 2A OR 230V AC, 2A Supply voltage Load voltage L+ Rated value (DC) 24 V Input current from load voltage L+ (without load), max.


    Original
    6ES7322-1HF01-0AA0 S7-300, 2012uit 20-pin PDF

    Contextual Info: Data sheet. SSS RELAIS 24V/230V 1AAC Weidmüller Interface GmbH & Co. KG Klingenbergstraße 16 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com TERMSERIES accessories include: • Spare relay • Base • Partition plates


    Original
    4V/230V D-32758 24-230VUC PDF

    230v aC PLC

    Abstract: wago 750
    Contextual Info: Fieldbus Independent I/O Modules 2DO 230V AC 2.0 A/Relay 2NO/ 750-513 Manual Version 1.0.3 ii • General Copyright 2006 by WAGO Kontakttechnik GmbH & Co. KG All rights reserved. WAGO Kontakttechnik GmbH & Co. KG Hansastraße 27 D-32423 Minden Phone: +49 0 571/8 87 – 0


    Original
    D-32423 g051214e g051215e D-32385 230v aC PLC wago 750 PDF

    440R-M23088

    Abstract: 440R-M23147 440R-M 440R-M23092 M23145 440r 440R-M23084 m23088 440R-M23089 440R-M23145
    Contextual Info: Safety Monitoring Relay with Delayed Outputs c_ Q_ I C€ MinotaurMSR138DP specifications Standards IEC/EN60204-I, ISOTRI2IOO, ISO 13849-1 EN 954-1 Safety Category Cat. 4 per EN 954-1 Approvals C E marked for all applicable directives Power Supply 24V A C /D C , 115V A C or 230V A C


    OCR Scan
    IEC/EN60204-I, 50/60Hz SRI38DP) AC-15, /250V A/24V 100ms 151230V 440R-M23088 440R-M23147 440R-M 440R-M23092 M23145 440r 440R-M23084 m23088 440R-M23089 440R-M23145 PDF

    230V ac relay

    Abstract: relay 230v 230v ac relay 1 contact 2no 1 nc relay 230V DC
    Contextual Info: 750-513 / 753-513 2-Channel Relay Output Module AC 230 V, DC 30 V isolated outputs; 2 make contacts K1 K2 Status relay 1 A C B Status relay 2 D 14 24 Data contacts 1 DO 1 DO 2 5 14 N 24 DO 13 23 Status 2 L1 6 L L2 13 23 3 7 4 8 750-513 750-513 Power jumper contact


    Original
    D-32385 D-32423 230V ac relay relay 230v 230v ac relay 1 contact 2no 1 nc relay 230V DC PDF

    676G

    Abstract: 230V ac relay E1UU230V01 f2 250v 1000VA 10VA
    Contextual Info: E1UU Monitoring relays - ENYA series AC/DC voltage monitoring in 1-phase mains Undervoltage monitoring 1 change over contact Width 17.5 mm Installation design Technical data 1. Functions Switching frequency: AC/DC undervoltage monitoring in 1-phase mains with adjustable threshold and fixed hysteresis.


    Original
    E1UU230V01 24VAC/DC 230VAC 676G 230V ac relay E1UU230V01 f2 250v 1000VA 10VA PDF

    potential transformer 230v ac

    Abstract: 230v dc to 440v ac 440v ac to 24v dc E1F3 DC230V 1000VA relay latch
    Contextual Info: TUW4X Monitoring relays – TREND series Industrial design Width 45mm AC/DC voltage monitoring in 1-phase mains Fault latch Position of output relay presettable 1 change over contact Technical data 1. Functions AC/DC voltage monitoring in 1-phase mains with adjustable


    Original
    PDF

    relay 230V DC

    Abstract: relay 12 volt 24v dc relay relay 12v mA relay 5 volt 230V ac relay coil R24-PCB 230V ac relay RELAY 24V ac 12V dc DC auxiliary relay
    Contextual Info: e Product Information & News Single Gang Auxiliary Relay Part no: RIU-R24B & RIU-R12B Description Dimensions The RIU-R24B 24v dc and the RIU-R12B ( 12v dc) auxiliary relays offer a rapid and cost effective solution to applications requiring addi­ tional switching of ancillary equipment.


    OCR Scan
    RIU-R24B RIU-R12B RIU-R24B availableR24-PCB) R24-BOX) RIU-R12B relay 230V DC relay 12 volt 24v dc relay relay 12v mA relay 5 volt 230V ac relay coil R24-PCB 230V ac relay RELAY 24V ac 12V dc DC auxiliary relay PDF

    MiniLine

    Abstract: NEC Class 2 ML50E111 D442 OVERLOAD RELAY mtbf
    Contextual Info: PULS MiniLine: practical, versatile and reliable like the SilverLine – yet small like no other: Data sheet MiniLine with plug-in screw terminals • 24-28 V DC/50 W output power • 100-240 V Wide Range Input 85-264 V AC permitted • DCok output • PULS Overload Design (does not switch


    Original
    DC/50 D-81925 ML50e111/040506 AC100-240V ML50e111/040506) MiniLine NEC Class 2 ML50E111 D442 OVERLOAD RELAY mtbf PDF

    230v to 12v dc circuit diagrams

    Abstract: relay TB1 225 230V ac to 12V dc circuit diagram single phase UPS 230V relay TB2-100 230v to convert 12v circuit diagram 230v to convert 12v power supply circuit diagram psp power switch diagram 5A 1 pole relay 220v ac 230v AC output
    Contextual Info: Serving the Automation & Control Industry since 1984. Introduction 20-100W, Single Phase Slimline Power Supplies NEW PRODUCT PS-S2005 PS-S2012 PS-S2015 PS-S2024 PS-S4005 PS-S4012 PS-S4024 PS-S4048 PS-S6005 PS-S6012 PS-S6024 PS-S6048 5 V DC 12V DC 15V DC 24V DC


    Original
    0-100W, PS-S2005 PS-S2012 PS-S2015 PS-S2024 PS-S4005 PS-S4012 PS-S4024 PS-S4048 PS-S6005 230v to 12v dc circuit diagrams relay TB1 225 230V ac to 12V dc circuit diagram single phase UPS 230V relay TB2-100 230v to convert 12v circuit diagram 230v to convert 12v power supply circuit diagram psp power switch diagram 5A 1 pole relay 220v ac 230v AC output PDF

    1000VA

    Abstract: 230V 1A RELAY
    Contextual Info: OIH3W Monitoring relays – OCTO series Installation design Width 35mm AC/DC current monitoring in 1-phase mains 1 change over contact and 1 normally open contact Technical data 1. Functions AC/DC current monitoring in 1-phase mains with adjustable threshold, timing for start-up suppression and tripping delay separately


    Original
    PDF

    IEC255 5A 250VAC

    Abstract: CM-SRN relay spdt 230v 2a 841 cm-esn spdt 24v 2a relay IEC-664 24V 3A SPDT 1a RELAY relay spdt 230v 2a 110-130VAC 1SVR450215
    Contextual Info: Current monitor, single phase AC/DC CM-SRS, CM-SRN 1SVR 430 841 F 1100 Ordering details ቢ ባ ቤ CM-SRS 1SVC 110 000 F 0103 Function OC B1/C B2/C B3/C OC c/o contact 1 c/o contact 2 ብ A1-A2 Supply voltage B1/C Measuring range 3-30mA B2/C Measuring range 10-100mA


    Original
    3-30mA 10-100mA 3-30mA 10-100mA Hysteresi10 EN50022) IEC255-6 93/68/EWG IEC255 5A 250VAC CM-SRN relay spdt 230v 2a 841 cm-esn spdt 24v 2a relay IEC-664 24V 3A SPDT 1a RELAY relay spdt 230v 2a 110-130VAC 1SVR450215 PDF

    pt100 relay

    Abstract: pt100 temperature control 230v ac to 24v dc without transformer 6v spdt relay Broyce Control 1902 transistor pt100 datasheet spdt 6v relay datasheet 45TCR pt100 out
    Contextual Info: Type: 45TCR PT100 Temperature Control Relay q q q q q q q 2 or 3 wire PT100 input Monitoring or control of temperature -50°°C to 300°°C 5 ranges Adjustable set point and hysteresis Relay Operation Inversion switch - Normal/Inverted Analogue output (0 - 10V DC) relative to set point or measured temperature


    Original
    45TCR PT100 45TCR DOC-A2001-05-09 pt100 relay pt100 temperature control 230v ac to 24v dc without transformer 6v spdt relay Broyce Control 1902 transistor pt100 datasheet spdt 6v relay datasheet pt100 out PDF

    contactor wiring diagram with timer

    Abstract: SDT 20 thermistor klixon start relay motor SDT 100 thermistor SDT 1000 thermistor star delta timer starter diagram STR-421 230V latching RELAY DPDT 12V
    Contextual Info: Avanti Electronic Devices Timing Modules Temperature Controller Page 11.2 Multi-Function timer - DIN mount Page 11.3 Multi-Function timer Page 11.4 Star Delta Timers Page 11.5 Delay-On Timer | Delay-On Timer plus Instant | Interval Timer | Equal Repeating Timer


    Original
    PDF

    relay 12v 6a

    Abstract: relay 24v 5a 12v relay 12V electromechanical relay knife edge isolation relay railway relay dc 24v ac 250v 16a 230V ac relay AC300V Z80000
    Contextual Info: interface flare Coupling relays The safe way to achieve a perfect interface in process applications. In the microchip age of bits and bytes, one might assume that there is no place left for electromechanical relays. Far from it! In control, transportation and


    Original
    35-mm relay 12v 6a relay 24v 5a 12v relay 12V electromechanical relay knife edge isolation relay railway relay dc 24v ac 250v 16a 230V ac relay AC300V Z80000 PDF