    TCR3DF18
    Toshiba Electronic Devices & Storage Corporation LDO Regulator, Fixed Output, 1.8 V, 300 mA, SOT-25 (SMV) Datasheet
    TCR15AGADJ
    Toshiba Electronic Devices & Storage Corporation LDO Regulator, Adjustable Output, 0.6 to 3.6 V, 1500 mA, WCSP6F Datasheet
    TCR3RM28A
    Toshiba Electronic Devices & Storage Corporation LDO Regulator, Fixed Output, 2.8 V, 300 mA, DFN4C/DFN4F Datasheet
    TCR2LF18
    Toshiba Electronic Devices & Storage Corporation LDO Regulator, Fixed Output, 1.8 V, 200 mA, SOT-25 (SMV) Datasheet
    TCR13AGADJ
    Toshiba Electronic Devices & Storage Corporation LDO Regulator, Adjustable Output, 0.55 to 3.6 V, 1300 mA, WCSP6F Datasheet

    Documents mentioning REGULATION TE

    Document Partial File Text Tags Type PDF
    lm150
    LM150/250 LM350 THREE-TERMINAL 3 A ADJUSTABLE VOLTAGE REGULATORS… GUARANTEED 3A OUTPUT CURRENT ADJUSTABLE OUTPUT DOWN TO 1.2V LINE REGULATION TYPICALLY 0.005% /V LOAD REGULATION TYPICALLY 0.1% GUARANTEED THERMAL REGULATION CURRENT LIMIT CONSTANT WITH TEMPERATURE
    Original PDF
    lm150
    LM150/250 LM350 THREE-TERMINAL 3 A ADJUSTABLE VOLTAGE REGULATORS… GUARANTEED 3A OUTPUT CURRENT ADJUSTABLE OUTPUT DOWN TO 1.2V LINE REGULATION TYPICALLY 0.005% /V LOAD REGULATION TYPICALLY 0.1% GUARANTEED THERMAL REGULATION CURRENT LIMIT CONSTANT WITH TEMPERATURE
    Original PDF
    lm138
    LM138/238 LM338 THREE-TERMINAL 5-A ADJUSTABLE VOLTAGE REGULATORS… GUARANTEED 7A PEAK OUTPUT CURRENT GUARANTEED 5A OUTPUT CURRENT ADJUSTABLE OUTPUT DOWN TO 1.2V LINE REGULATION TYPICALLY 0.005% /V LOAD REGULATION TYPICALLY 0.1% GUARANTEED THERMAL REGULATION
    Original PDF
    lm138
    LM138/238 LM338 THREE-TERMINAL 5-A ADJUSTABLE VOLTAGE REGULATORS… GUARANTEED 7A PEAK OUTPUT CURRENT GUARANTEED 5A OUTPUT CURRENT ADJUSTABLE OUTPUT DOWN TO 1.2V LINE REGULATION TYPICALLY 0.005% /V LOAD REGULATION TYPICALLY 0.1% GUARANTEED THERMAL REGULATION
    Original PDF
    Principles of SMPS Technical Information
    Principles of SMPS Technical Information Topologies Topologies Voltage Regulation 13022 Ferro-resonant Regulation Ii Ferro-resonant techniques generate a line regulation by means of a resonant tank circuit and provide inherent isolation between primary and secondary windings.
    Original PDF
    WHAT IS REGULATION AND REPEATABILITY? APP Note
    WHAT IS REGULATION AND REPEATABILITY? APP Note 509 Regulation and Repeatability The terms regulation and repeatability are often used to describe the same phenomena in capacitor charging power supplies. They should not be confused with similar terms for continuous DC power
    Original PDF
    lm150
    LM150/LM250 LM350 THREE-TERMINAL 3 A ADJUSTABLE VOLTAGE REGULATORS ■ GUARANTEED 3A OUTPUT CURRENT ■ ADJUSTABLE OUTPUT DOWN TO 1.2V ■ LINE REGULATION TYPICALLY 0.005%/V ■ LOAD REGULATION TYPICALLY 0.1% ■ GUARANTEED THERMAL REGULATION ■ CURRENT LIMIT CONSTANT WITH
    Original PDF
    LM150/LM250 LM350 THREE-TERMINAL 3 A ADJUSTABLE
    LM150/LM250 LM350 THREE-TERMINAL 3 A ADJUSTABLE VOLTAGE REGULATORS ■ GUARANTEED 3A OUTPUT CURRENT ■ ADJUSTABLE OUTPUT DOWN TO 1.2V ■ LINE REGULATION TYPICALLY 0.005%/V ■ LOAD REGULATION TYPICALLY 0.1% ■ GUARANTEED THERMAL REGULATION ■ CURRENT LIMIT CONSTANT WITH
    Original PDF
    REVISIONS LTR DESCRIPTION DATE (YR-MO-DA)
    REVISIONS LTR DESCRIPTION DATE (YR-MO-DA) APPROVED A Change to military drawing format. Changes to output adjustment range. Add conditions for load regulation test at -55GC and +125GC. Change group A subgroups for load regulation and line regulation tests, and output voltage
    Original PDF
    lm350
    LM350 Three-terminal 3 A adjustable voltage regulators Features ■ Guaranteed 3 A output current ■ Adjustable output down to 1.2 V ■ Line regulation typically 0.005 %/V ■ Load regulation typically 0.1 % ■ Guaranteed thermal regulation ■ Current limit constant with temperature
    Original PDF
    flyback
    Flyback topology – Accurate Primary Side Sensing Describes how CamSemi can achieve tight regulation with primary side sensing techniques • Tight voltage regulation ±5% • Proprietary and patented technique for tight current regulation ±5% • Removal of up to 11 components used in feedback process
    Original PDF
    REVISIONS LTR DESCRIPTION DATE (YR-MO-DA)
    REVISIONS LTR DESCRIPTION DATE (YR-MO-DA) APPROVED A Change to military drawing format. Changes to output adjustment range. Add conditions for load regulation test at -55°C and +125°C. Change group A subgroups for load regulation and line regulation tests, and output voltage
    Original PDF
    REVISIONS LTR DESCRIPTION DATE (YR-MO-DA)
    REVISIONS LTR DESCRIPTION DATE (YR-MO-DA) APPROVED A Change to military drawing format. Changes to output adjustment range. Add conditions tor load regulation test at -5!?C and +125°C. Change group A subgroups for load regulation and line regulation tests, and output voltage
    OCR Scan PDF
    REVISIONS LTR DESCRIPTION DATE (YR-MO-DA)
    REVISIONS LTR DESCRIPTION DATE (YR-MO-DA) APPROVED A Add vendor CAGE U4637 and 69210. Add case outlines T and U. Change test limits for line regulation, load regulation, standby current drain and standby current drain with line tests. Change test conditions for line regulation and
    Original PDF
    REVISIONS LTR DESCRIPTION DATE (YR-MO-DA)
    REVISIONS LTR DESCRIPTION DATE (YR-MO-DA) APPROVED A Add vendor CAGE U4637 and 69210. Add case outlines T and U. Change test limits for line regulation, load regulation, standby current drain and standby current drain with line tests. Change test conditions for line regulation and
    Original PDF
    REVISIONS LTR APPROVED DATE (YR-MO-DA)
    REVISIONS LTR APPROVED DATE (YR-MO-DA) DESCRIPTION Add vendor CAGE U4637 and 69210. Add case outlines T and U. Change test limits "for line regulation, load regulation, standby current drain, and standby current drain with line tests. Change test conditions for line regulation and output voltage tests. Add
    OCR Scan PDF
    Application Guide DCAN-19 Effects of Lead
    Application Guide DCAN-19 Effects of Lead Resistances on Load Regulation Parmeter Line Regulation Load Regulation Conditions High Line to Low Line Rated Load to No Load Min Typ +0.5 +0.1 Max +1.0 +0.5 Units % % When the load regulation is specified for a DC/DC converter, it is assumed to be
    Original PDF
    ex355
    Technical Specifications EX series EX355P MAIN OUTPUTS Voltage Range: Current Range: Operating Mode: Voltage Setting: Current Setting: Load regulation: Line regulation: Output impedance: Ripple & Noise (20MHz bandwidth): Transient Response: Temp. Coefficient:
    Original PDF
    dcp0105
    DCP0105 ADDENDUM SPECIFICATIONS (DCP010512P) At TA = +25°C, VOUT nominal (VNOM) = +12V, and VS = +5V, unless otherwise specified. DCP010512P PARAMETER OUTPUT Voltage (VNOM) Noise and Ripple INPUT Supply Current REGULATION Load Regulation Line Regulation EFFICIENCY
    Original PDF
    dcp0105
    DCP0105 ADDENDUM SPECIFICATIONS (DCP010515P) At TA = +25°C, VOUT nominal (VNOM) = +15V, and VS = +5V, unless otherwise specified. DCP010515P PARAMETER OUTPUT Voltage (VNOM) Noise and Ripple INPUT Supply Current REGULATION Load Regulation Line Regulation EFFICIENCY