Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    RECEPTACLE INSERTION PROCEDURE Search Results

    RECEPTACLE INSERTION PROCEDURE Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    77428-125LF
    Amphenol Communications Solutions Metral® , Backplane Connectors, Power Insert, Receptacle, Straight, Crimp to Wire. PDF
    77428-124LF
    Amphenol Communications Solutions Metral® , Backplane Connectors, Power Insert, Receptacle, Straight, Crimp to Wire. PDF
    77428-134LF
    Amphenol Communications Solutions Metral® , Backplane Connectors, Power Insert, Receptacle, Straight, Crimp to Wire. PDF
    77428-144LF
    Amphenol Communications Solutions Metral® , Backplane Connectors, Power Insert, Receptacle, Straight, Crimp to Wire. PDF
    77428-145LF
    Amphenol Communications Solutions Metral® , Backplane Connectors, Power Insert, Receptacle, Straight, Crimp to Wire. PDF

    Documents mentioning RECEPTACLE INSERTION PROCEDURE

    Document Partial File Text Tags Type PDF
    Instruction Sheet 408–6929 Terminating Head
    Instruction Sheet 408–6929 Terminating Head 58246–1 for MTA–100 Receptacle Connectors Locating Pawl 16 JUL 03 Rev C MTA–100 Receptacle Connectors (Closed–End Style Only) Adjuster (Insertion Rod) for Setting Wire Inserter Adjustment Tool Base With Lock
    Original PDF
    58246-1
    Instruction Sheet 408-6929 AMP* Terminating Head 58246-1 for MTA-100 Receptacle Connectors AMP LOCATING PAWL 03 MAY 94 RevB MTA-100 RECEPTACLE CONNECTORS (Closed-End Style Only) ADJUSTER (Insertion Rod) FOR SETTING WIRE INSERTER ADJUSTMENT & TOOL BASE FEED
    OCR Scan PDF
    AMP Mass Insertion Terminating Head 58646-1 for
    AMP Mass Insertion Terminating Head 58646-1 for MTA (Mass Termination Assembly) 156 Feed-Through Receptacle Connectors instruction Sheet 408-4405 09 JUN 97 RevO Figure 1 1. INTRODUCTION AMP* Mass Insertion Terminating Head 58646-1, shown in Figure 1, is designed to terminate AMP MTA
    OCR Scan PDF
    mx150
    MX150/MX150L ASSEMBLY INSTRUCTIONS RECEPTACLE ASSEMBLY TERMINAL INSERTION 1. Begin assembly of the crimped female terminals into the receptacle housing by making sure the Terminal Position Assurance feature (TPA) is in the pre-locked position (See Figure 1). If it is not, insert the blade of a screwdriver into the slots
    Original PDF
    Ribbon Cable Mass Insertion Terminating Head
    Ribbon Cable Mass Insertion Terminating Head 58646-2 for MTA (Mass Termination Assembly) 156 Feed-Through Receptacle Connectors 408“ 4439 17 s e p 97 Rev o Figure 1 1. INTRODUCTION AMP* Mass Insertion Terminating Head 58646-2, shown in Figure 1, is designed to terminate AMP MTA
    OCR Scan PDF
    TECH NICAL Page DATA R113.424.200 STRAIGHT
    TECH NICAL Page DATA R113.424.200 STRAIGHT RECEPTACLE SMT 50 NOMINAL IMPEDANCE V.S.W.R GHz -55/+155 TEMPERATURE RATING 1.25 Ox +■ NA RF INSERTION LOSS 'C F (GHz) Maxi #iGHz) dB Maxi 335 Veff Maxi DIELECTRIC WITHSTANDING VOLTAGE 1000 Veff Mini INSULATION RESISTANCE
    OCR Scan PDF
    TECHNICAL DATA Page 1 / 3 R114.423.800 STRAIGHT
    TECHNICAL DATA Page 1 / 3 R114.423.800 STRAIGHT PLUG RECEPTACLE FOR PCB SMT TYPE - EDGE CARO SM B SE R IE S Resistance c.contact (c.central) = 8 MnMaxi Resistance outer contact (c.masse) = 1.5 MnMaxi Engage force (insertion) = 60 N Maxi Desengage force (extraction) = 20 N Maxi
    OCR Scan PDF
    Catalog 1307612 AMP FASTON Insulated and
    Catalog 1307612 AMP FASTON Insulated and Uninsulated Terminals Revised 7-01 250 Series Test Tabs 250 Series Test Tabs Mate with all “ 250” Series FASTON Receptacles Test Tabs The mechanical tab is mounted onto AMP gauge 100505 for testing of receptacle insertion/
    OCR Scan PDF
    TECHNICAL DATA Page 1 I 3 R124.423.033 STRAIGHT
    TECHNICAL DATA Page 1 I 3 R124.423.033 STRAIGHT JACK RECEPTACLE SMT SM A B SER IE8 □IA 0.307 □IA 0.02 (00.5) 0.313 (7.95) 0.079 1 0.709 (18) NOMINAL IMPEDANCE 50 0 4.8 GHz FREQUENCY RANGE - TEMPERATURE RATING V.S.W.R CABLES : n -65/+105 1.05 + RF INSERTION LOSS
    OCR Scan PDF
    TECHNICAL Page DATA 1 I 3 R128.424.848 STRAIGHT
    TECHNICAL Page DATA 1 I 3 R128.424.848 STRAIGHT PLU6 RECEPTACLE FOR PCB SMT TYPE BMA COM SERI ES 0.059 (8.5) * Minimum height.Could be increased to 8 max (7.97 *0.03) 50 NOMINAL IMPEDANCE 0-3 FREQUENCY RANGE TEMPERATURE RATING V.S.W.R -65/+125 1 . 02 + RF INSERTION LOSS
    OCR Scan PDF
    rp34series
    U ) C RP34SERIES J 1 N J COMPACT PLASTIC CONNECTOR FOR AC ADAPTER ■ Scope \ Plug is available in either straight type or right-angle type. Right angle type offers low insertion profile. The receptacle is a very compact part w ith a 10mmsquare mating surface and 11.3mm depth.
    OCR Scan PDF
    TECHNICAL Page DATA RIGHT ANGLE JACK RECEPTACLE
    TECHNICAL Page DATA RIGHT ANGLE JACK RECEPTACLE FOR PCB SMT TYPE - REEL OF 100 □ .248 (□ 6.31) 1 I 3 R124.681.800 SMA-COM s e r ie s 0.382 (9.7) m 50 NOMINAL IMPEDANCE FREQUENCY RANGE 0- 6 TEMPERATURE RATING V.S.W.R -65/+165 1 . 16 + RF INSERTION LOSS
    OCR Scan PDF
    receptacle
    TECHNICAL DATA Page 1 I 3 R114.423.000 STRAIGHT PLUG RECEPTACLE FOR PCB SMT TYPE - EDGE CARD SMB 8 E R IE 8 11.45 CORPS SEUL 1.4 5.15 f in o -e - 5.5 NOMINAL IMPEDANCE 50 FREQUENCY RANGE 0-4 TEMPERATURE RATING V.S.W.R -65/+165 1.05# + RF INSERTION LOSS CABLES :
    OCR Scan PDF
    ENGINEERING PROCEDURE BUS-12-121 1 16 D SCA
    ENGINEERING PROCEDURE BUS-12-121 1 16 D SCA Product Specification D. McClune 1.0 12/23/98 OBJECTIVE This specification defines the performance, test, quality and reliability requirements of the SCA (Single Connect Attach) system. 2.0 SCOPE This specification is applicable to the termination characteristics of the SCA family of products which
    Original PDF
    airmax
    COMMUNICATIONS, DATA, CONSUMER DIVISION AirMax VS® High-Speed Connector System Signal Integrity Test Procedures and Performance FCI: SETTING THE STANDARD FOR CONNECTORS With operations in 30 countries, FCI is a leading manufacturer of connectors. Our 13,500 employees
    Original PDF
    D EU TSC H DRC SERIES TECHNICAL MANUAL DRC SERIES
    D EU TSC H DRC SERIES TECHNICAL MANUAL DRC SERIES Contact Retention System LOCKING FINGERS I CONTACT L 1 - p H T UNLOCKED POSITION — -1 H H CONTACT INSERTION I J B CONTACT LOCKED IN POSITION CONTACT INSERTION PROCEDURE Dt TOOL INSERTED TO UNLOCK CONTACT
    OCR Scan PDF