| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| 77428-125LF | Amphenol Communications Solutions | Metral® , Backplane Connectors, Power Insert, Receptacle, Straight, Crimp to Wire. | |||
| 77428-124LF | Amphenol Communications Solutions | Metral® , Backplane Connectors, Power Insert, Receptacle, Straight, Crimp to Wire. | |||
| 77428-134LF | Amphenol Communications Solutions | Metral® , Backplane Connectors, Power Insert, Receptacle, Straight, Crimp to Wire. | |||
| 77428-144LF | Amphenol Communications Solutions | Metral® , Backplane Connectors, Power Insert, Receptacle, Straight, Crimp to Wire. | |||
| 77428-145LF | Amphenol Communications Solutions | Metral® , Backplane Connectors, Power Insert, Receptacle, Straight, Crimp to Wire. |
Documents mentioning RECEPTACLE INSERTION PROCEDURE
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| Instruction Sheet 408–6929 Terminating Head | Instruction Sheet 408–6929 Terminating Head 58246–1 for MTA–100 Receptacle Connectors Locating Pawl 16 JUL 03 Rev C MTA–100 Receptacle Connectors (Closed–End Style Only) Adjuster (Insertion Rod) for Setting Wire Inserter Adjustment Tool Base With Lock |
Original | ||||
| 58246-1 | Instruction Sheet 408-6929 AMP* Terminating Head 58246-1 for MTA-100 Receptacle Connectors AMP LOCATING PAWL 03 MAY 94 RevB MTA-100 RECEPTACLE CONNECTORS (Closed-End Style Only) ADJUSTER (Insertion Rod) FOR SETTING WIRE INSERTER ADJUSTMENT & TOOL BASE FEED |
OCR Scan | ||||
| AMP Mass Insertion Terminating Head 58646-1 for | AMP Mass Insertion Terminating Head 58646-1 for MTA (Mass Termination Assembly) 156 Feed-Through Receptacle Connectors instruction Sheet 408-4405 09 JUN 97 RevO Figure 1 1. INTRODUCTION AMP* Mass Insertion Terminating Head 58646-1, shown in Figure 1, is designed to terminate AMP MTA |
OCR Scan | ||||
| mx150 | MX150/MX150L ASSEMBLY INSTRUCTIONS RECEPTACLE ASSEMBLY TERMINAL INSERTION 1. Begin assembly of the crimped female terminals into the receptacle housing by making sure the Terminal Position Assurance feature (TPA) is in the pre-locked position (See Figure 1). If it is not, insert the blade of a screwdriver into the slots |
Original | ||||
| Ribbon Cable Mass Insertion Terminating Head | Ribbon Cable Mass Insertion Terminating Head 58646-2 for MTA (Mass Termination Assembly) 156 Feed-Through Receptacle Connectors 408“ 4439 17 s e p 97 Rev o Figure 1 1. INTRODUCTION AMP* Mass Insertion Terminating Head 58646-2, shown in Figure 1, is designed to terminate AMP MTA |
OCR Scan | ||||
| TECH NICAL Page DATA R113.424.200 STRAIGHT | TECH NICAL Page DATA R113.424.200 STRAIGHT RECEPTACLE SMT 50 NOMINAL IMPEDANCE V.S.W.R GHz -55/+155 TEMPERATURE RATING 1.25 Ox +■ NA RF INSERTION LOSS 'C F (GHz) Maxi #iGHz) dB Maxi 335 Veff Maxi DIELECTRIC WITHSTANDING VOLTAGE 1000 Veff Mini INSULATION RESISTANCE |
OCR Scan | ||||
| TECHNICAL DATA Page 1 / 3 R114.423.800 STRAIGHT | TECHNICAL DATA Page 1 / 3 R114.423.800 STRAIGHT PLUG RECEPTACLE FOR PCB SMT TYPE - EDGE CARO SM B SE R IE S Resistance c.contact (c.central) = 8 MnMaxi Resistance outer contact (c.masse) = 1.5 MnMaxi Engage force (insertion) = 60 N Maxi Desengage force (extraction) = 20 N Maxi |
OCR Scan | ||||
| Catalog 1307612 AMP FASTON Insulated and | Catalog 1307612 AMP FASTON Insulated and Uninsulated Terminals Revised 7-01 250 Series Test Tabs 250 Series Test Tabs Mate with all “ 250” Series FASTON Receptacles Test Tabs The mechanical tab is mounted onto AMP gauge 100505 for testing of receptacle insertion/ |
OCR Scan | ||||
| TECHNICAL DATA Page 1 I 3 R124.423.033 STRAIGHT | TECHNICAL DATA Page 1 I 3 R124.423.033 STRAIGHT JACK RECEPTACLE SMT SM A B SER IE8 □IA 0.307 □IA 0.02 (00.5) 0.313 (7.95) 0.079 1 0.709 (18) NOMINAL IMPEDANCE 50 0 4.8 GHz FREQUENCY RANGE - TEMPERATURE RATING V.S.W.R CABLES : n -65/+105 1.05 + RF INSERTION LOSS |
OCR Scan | ||||
| TECHNICAL Page DATA 1 I 3 R128.424.848 STRAIGHT | TECHNICAL Page DATA 1 I 3 R128.424.848 STRAIGHT PLU6 RECEPTACLE FOR PCB SMT TYPE BMA COM SERI ES 0.059 (8.5) * Minimum height.Could be increased to 8 max (7.97 *0.03) 50 NOMINAL IMPEDANCE 0-3 FREQUENCY RANGE TEMPERATURE RATING V.S.W.R -65/+125 1 . 02 + RF INSERTION LOSS |
OCR Scan | ||||
| rp34series | U ) C RP34SERIES J 1 N J COMPACT PLASTIC CONNECTOR FOR AC ADAPTER ■ Scope \ Plug is available in either straight type or right-angle type. Right angle type offers low insertion profile. The receptacle is a very compact part w ith a 10mmsquare mating surface and 11.3mm depth. |
OCR Scan | ||||
| TECHNICAL Page DATA RIGHT ANGLE JACK RECEPTACLE | TECHNICAL Page DATA RIGHT ANGLE JACK RECEPTACLE FOR PCB SMT TYPE - REEL OF 100 □ .248 (□ 6.31) 1 I 3 R124.681.800 SMA-COM s e r ie s 0.382 (9.7) m 50 NOMINAL IMPEDANCE FREQUENCY RANGE 0- 6 TEMPERATURE RATING V.S.W.R -65/+165 1 . 16 + RF INSERTION LOSS |
OCR Scan | ||||
| receptacle | TECHNICAL DATA Page 1 I 3 R114.423.000 STRAIGHT PLUG RECEPTACLE FOR PCB SMT TYPE - EDGE CARD SMB 8 E R IE 8 11.45 CORPS SEUL 1.4 5.15 f in o -e - 5.5 NOMINAL IMPEDANCE 50 FREQUENCY RANGE 0-4 TEMPERATURE RATING V.S.W.R -65/+165 1.05# + RF INSERTION LOSS CABLES : |
OCR Scan | ||||
| ENGINEERING PROCEDURE BUS-12-121 1 16 D SCA | ENGINEERING PROCEDURE BUS-12-121 1 16 D SCA Product Specification D. McClune 1.0 12/23/98 OBJECTIVE This specification defines the performance, test, quality and reliability requirements of the SCA (Single Connect Attach) system. 2.0 SCOPE This specification is applicable to the termination characteristics of the SCA family of products which |
Original | ||||
|
|
||||||
| airmax | COMMUNICATIONS, DATA, CONSUMER DIVISION AirMax VS® High-Speed Connector System Signal Integrity Test Procedures and Performance FCI: SETTING THE STANDARD FOR CONNECTORS With operations in 30 countries, FCI is a leading manufacturer of connectors. Our 13,500 employees |
Original | ||||
| D EU TSC H DRC SERIES TECHNICAL MANUAL DRC SERIES | D EU TSC H DRC SERIES TECHNICAL MANUAL DRC SERIES Contact Retention System LOCKING FINGERS I CONTACT L 1 - p H T UNLOCKED POSITION — -1 H H CONTACT INSERTION I J B CONTACT LOCKED IN POSITION CONTACT INSERTION PROCEDURE Dt TOOL INSERTED TO UNLOCK CONTACT |
OCR Scan | ||||