Pilz International 777587 (PZE X4.1P 24VDC 4N/O)SAFETY RELAY, CONTACT EXPANSION, 1 OR 2 CH, 24 VDC, 4 NO, SCREW TERM, PZE SERIES |
|||||||||||
| Distributors | Part | Package | Stock | Lead Time | Min Order Qty | Price | Buy | ||||
|
777587 (PZE X4.1P 24VDC 4N/O) | Bulk | 21 | 35 Weeks | 1 |
|
Buy Now | ||||
Pilz International 774585 (PZE X4 24VDC 4N/O)SAFETY RELAY, LED INDICTOR, 24VDC, 4NO, 774585, SCREW TERMINAL, PZE X4 SERIES |
|||||||||||
| Distributors | Part | Package | Stock | Lead Time | Min Order Qty | Price | Buy | ||||
|
774585 (PZE X4 24VDC 4N/O) | Bulk | 18 | 35 Weeks | 1 |
|
Buy Now | ||||
Pilz International 774584 (PZE X4V 8/24VDC 4N/O)CONTACT EXPANSION INPUTS: SINGLE-CHANNEL WIRING OUTPUTS: 4 N/O (T= 5.6.7.8 S). |
|||||||||||
| Distributors | Part | Package | Stock | Lead Time | Min Order Qty | Price | Buy | ||||
|
774584 (PZE X4V 8/24VDC 4N/O) | Bulk | 2 | 4 Weeks | 1 |
|
Buy Now | ||||
Pilz International 774582 (PZE X4V 2/24VDC 4N/O FIX)CONTACT EXPANSION INPUTS: SINGLE-CHANNEL WIRING OUTPUTS: 4 N/O UB 24 VDC. |
|||||||||||
| Distributors | Part | Package | Stock | Lead Time | Min Order Qty | Price | Buy | ||||
|
774582 (PZE X4V 2/24VDC 4N/O FIX) | Bulk | 1 | 35 Weeks | 1 |
|
Buy Now | ||||
Pilz International 774581 (PZE X4V 1/24VDC 4N/O FIX)SAFETY RELAY, 1 CHANNEL 2 NO, 24 VDC, SCREW TERM, PNOZ SERIES |
|||||||||||
| Distributors | Part | Package | Stock | Lead Time | Min Order Qty | Price | Buy | ||||
|
774581 (PZE X4V 1/24VDC 4N/O FIX) | Bulk | 1 | 35 Weeks | 1 |
|
Buy Now | ||||
Documents mentioning PZE X4
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| pze x4 | Expander Modules Instantaneous PZE X4 Technical Details Electrical Data Supply Voltage Tolerance Power Consumption Maximum Sum of Output Current Switching Capability in accordance with EN 60947-4-1, 10/91 Expander module in accordance with VDE 0113-1, 11/98, EN 60204-1, |
Original | ||||
| pze x4 | Expander modules Instantaneous PZE X4 Unit features Safety features ` Positive-guided relay outputs: – 4 safety contacts (N/O), instantaneous ` Safe separation of safety contacts 13-14, 23-24, 33-34 from input circuit A1 and feedback loop Y1-Y2 ` Connection for feedback loop |
Original | ||||
| Contact expansion modules Up to PL e of EN ISO | Contact expansion modules Up to PL e of EN ISO 13849-1 PZE X4.1P Unit features ` Positive-guided relay outputs: – 4 safety contacts (N/O), instantaneous ` Safe separation of safety contacts 13-14, 23-24, 33-34 from input circuits K1-U-K2 and feedback loop |
Original | ||||
| Expander modules Delayed PZE X4V Unit features | Expander modules Delayed PZE X4V Unit features Safety features ` Positive-guided relay outputs: – 4 safety contacts (N/O), delay-on de-energisation ` Connection for feedback loop ` LED indicator for: – Switch status channel 1/2 ` See order reference for unit types |
Original | ||||
| Contact expansion modules Up to PL d of EN ISO | Contact expansion modules Up to PL d of EN ISO 13849-1 PZE X4VP8 Unit features Safety features ` Positive-guided relay outputs: – 4 safety contacts (N/O), delay-on de-energisation ` LED indicator for: – Switch status channel 1/2 ` Plug-in connection terminals (either |
Original | ||||
| Expander modules Delayed PZE X4V8 Unit features | Expander modules Delayed PZE X4V8 Unit features Safety features ` Positive-guided relay outputs: – 4 safety contacts (N/O), delay-on de-energisation ` LED indicator for: – Switch status channel 1/2 The unit meets the following safety requirements: ` The contact expansion module expands an existing circuit. As the |
Original | ||||
| Contact expansion modules Up to PL d of EN ISO | Contact expansion modules Up to PL d of EN ISO 13849-1 PZE X4VP Unit features Safety features ` Positive-guided relay outputs: – 4 safety contacts (N/O), delay-on de-energisation ` LED indicator for: – Switch status channel 1/2 ` Plug-in connection terminals (either |
Original | ||||
| Expander modules Delayed PZE X4V Unit features | Expander modules Delayed PZE X4V Unit features Safety features ` Positive-guided relay outputs: – 4 safety contacts (N/O), delay-on de-energisation ` Connection for feedback loop ` LED indicator for: – Switch status channel 1/2 ` See order reference for unit types |
Original | ||||
| Contact expansion modules Up to PL d of EN ISO | Contact expansion modules Up to PL d of EN ISO 13849-1 PZE X4VP4 Unit features Safety features ` Positive-guided relay outputs: ` 4 safety contacts (N/O), delay-on de-energisation ` LED indicator for: – Switch status channel 1/2 ` Plug-in connection terminals (either |
Original | ||||
| pze x4p | Expansion modules Up to PL e of EN ISO 13849-1 PZE X4P Unit features Safety features ` Positive-guided relay outputs: – 4 safety contacts (N/O), instantaneous ` LED indicator for: – Switch status channel 1/2 ` Plug-in connection terminals (either spring-loaded terminal or screw |
Original | ||||
| Issued March 1995 019-240 Data Pack D Data Sheet | Issued March 1995 019-240 Data Pack D Data Sheet RS stock no. 314-400 314-416 316-383 316-399 758-399 758-406 758-428 758-434 316-406 316-412 316-428 759-285 316-440 Safety relays – A guide to the European machine safety directive Pilz part no. PNOZ/24Vdc |
Original | ||||
| pnoz | Issued November 1993 D16724 Safety relays Ð A guide to the European machine safety directive RS stock no. 314-400 314-416 316-383 316-399 758-399 758-406 758-428 758-434 316-406 316-412 316-428 759-266 316-440 Pilz part no. PNOZ/24Vdc PNOZ/110Vac PNOZ2/110Vac |
Original | ||||
| Issued March 1997 232-5193 Data Pack D Data Sheet | Issued March 1997 232-5193 Data Pack D Data Sheet RS stock no. 314-400 314-416 316-383 316-399 758-399 758-406 758-428 758-434 316-406 316-412 316-428 759-285 316-440 Safety relays – A guide to the European machine safety directive Pilz part no. PNOZ/24Vdc |
Original | ||||
| pilz | IE NZ Pilz GmbH & Co. KG Sichere Automation Felix-Wankel-Straße 2 73760 Ostfildern Germany Telephone: +49 711 3409-0 Telefax: +49 711 3409-133 E-Mail: pilz.gmbh@pilz.de Pilz Ireland Industrial Automation Cork Business and Technology Park Model Farm Road |
Original |