| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| CO-059FTYPEMM-025 | Amphenol Cables on Demand | Amphenol CO-059FTYPEMM-025 F-Type Coax Cable - RG59 75 Ohm Coaxial Cable - Type F Male / Type F Male (TV/CABLE/SATELLITE) 25 ft | |||
| CO-059FTYPEMM-010 | Amphenol Cables on Demand | Amphenol CO-059FTYPEMM-010 F-Type Coax Cable - RG59 75 Ohm Coaxial Cable - Type F Male / Type F Male (TV/CABLE/SATELLITE) 10 ft | |||
| CO-059FTYPEMM-050 | Amphenol Cables on Demand | Amphenol CO-059FTYPEMM-050 F-Type Coax Cable - RG59 75 Ohm Coaxial Cable - Type F Male / Type F Male (TV/CABLE/SATELLITE) 50 ft | |||
| CO-059FTYPEMM-003 | Amphenol Cables on Demand | Amphenol CO-059FTYPEMM-003 F-Type Coax Cable - RG59 75 Ohm Coaxial Cable - Type F Male / Type F Male (TV/CABLE/SATELLITE) 3 ft | |||
| CO-059FTYPEMM-006 | Amphenol Cables on Demand | Amphenol CO-059FTYPEMM-006 F-Type Coax Cable - RG59 75 Ohm Coaxial Cable - Type F Male / Type F Male (TV/CABLE/SATELLITE) 6 ft |
Documents mentioning PT100 TYPE B
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| rtd input | 4-channel Isolated RTD Input Module Specifications Analog Input 4 16 bits, 10 samples/sec., 12 bits, 100 samples/sec. (optional) Input type Pt and Ni RTD RTD type and Type Range ∂ temperature ranges Pt100 -100˚C ~ 100˚C 0.00385 Pt100 0˚C ~ 100˚C 0.00385 |
Original | ||||
| temperature controller | TEMPERATURE CONTROLLER MOUNTED ON A 35 mm RAIL RE60 TYPE Current flowing through Pt100 < 220 mA Measurement time 0.5 s Detection of error in the measuring circuit: - thermocouple, Pt100 overflow of the measuring range Kinds of outputs: - relay voltageless make contacts |
Original | ||||
| 45tcr | Type: 45TCR PT100 Temperature Control Relay q q q q q q q 2 or 3 wire PT100 input Monitoring or control of temperature -50°°C to 300°°C (5 ranges) Adjustable set point and hysteresis Relay Operation Inversion switch - Normal/Inverted Analogue output (0 - 10V DC) relative to set point or measured temperature |
Original | ||||
| 2.0 Push Button PT100 Tx Temperature Transmitter | 2.0 Push Button PT100 Tx Temperature Transmitter RECEIVING AND UNPACKING 3.0 SPECIFICATION @ 20 °C INPUT Sensor Type Sensor Range Sensor Connection Minimum span (see note 1) Linearisation Accuracy (see note 2) Thermal Drift Excitation current Lead Resistance effect |
Original | ||||
| thermometer | TRANSDUCER SUPPLIED FROM A CURRENT LOOP P15 TYPE Range of analog output 4…20 mA Analog output resolution 0.005 mA Basic error 0.2 % of the range Conversion time Power consumption 1s < 0.7 VA Current flowing through the resistance thermometer: - Pt100 or resistance |
Original | ||||
| pt100 | CombiTemp TFRH TM Hygienic – RTD temperature sensor Main features Pt100 sensor element, 2- or 4-wire Built in graphical display, CombiViewTM DFON optional Head mounted 4…20 mA transmitter, FlexTop type 22xx HART®, PA ATEX |
Original | ||||
| m1mpt100 | M1MPT100 24-240V Signal converters - M1 series Temperature transmitter for temperatures from -100 up to +700°C Multifunction Signal type and measuring range preselection via DIP-switch Approved for temperature sensors Pt100 and Pt1000 2-wire, 3-wire and 4-wire sensors |
Original | ||||
| CombiTemp, Mesure de température Concept | CombiTemp, Mesure de température Concept modulaire extrêmement flexible Toutes les pièces en contact avec le fluide sont en acier inoxydable résistant aux acides Capteurs Pt100 ou Pt1000, 2 ou 4 fils Composants DIN A ou B (1/1, 1/3, 1/6) Sonde type plongeur |
Original | ||||
| temperature transmitter | + - B1 B2 B3 TEMPERATURE TRANSMITTER + TEMPERATURE TRANSMITTER 25 50 75 75,0 mm - B1 B2 B3 LIMIT 100 DIFF. Z E R O O N S P A N A1 A2 Z E R O Type: TAMA & TAMB S P A N 12 11 14 35,0 mm PT100 TEMPERATURE TRANSMITTER A1 A2 45,0 mm 100,0 mm FEATURES: Description: |
Original | ||||
| Temperature Measuring Amplifer for PT100 RTD’s | Temperature Measuring Amplifer for PT100 RTD’s with/without Alarm Output The narrow 19mm DIN rail mountable measuring amplifier, accepts a signal from a PT-100 sensor (per DIN E C 751) and then linearizes, amplifies and adjusts it to a standard signal type e.g. 0..10V or |
OCR Scan | ||||
| Intrinsic Safety Isolation Barriers SIB 1000 | Intrinsic Safety Isolation Barriers SIB 1000 Series 380 $ Basic Unit C A B A B ߜ Input Output Isolation ߜ For J, K, T, E, R, S, B Thermocouples, mV, and Pt100 and Ni100 RTDs ߜ Converts Signal from Hazardous Location into 4 to 20 mA Signal ߜ Field Programmable |
Original | ||||
| CombiTemp TFRN TM Industrial – RTD temperature | CombiTemp TFRN TM Industrial – RTD temperature sensor Main features Pt100 sensor element, ATEX Programmable by touch screen Easy and full programmable 2- or 4-wire HART®, PA Built in graphical display, CombiViewTM DFON optional |
Original | ||||
| CombiTemp TCR6 Standard RTD temperature sensor | CombiTemp TCR6 Standard RTD temperature sensor Main features Sensor and connection in stainless steel, AISI 316L DIN form B housing Robust design Applications Industrial applications with Water systems Tanks and vessels industrial process connection |
Original | ||||
| Temperature Measurement © Siemens AG 2012 | Temperature Measurement © Siemens AG 2012 Transmitters for mounting in sensor head SITRANS TH100 two-wire system (Pt100) ■ Overview ■ Application Used in conjunction with Pt100 resistance thermometers, the SITRANS TH100 transmitters are ideal for measuring temperatures in all industries. Due to its compact size it can be installed |
Original | ||||
|
|
||||||
| pt100 sensor | Programmable Loop-Powered Temperature Measuring Transducer for PT100 Sensors MCR-SL-PT100-LP-I 1. Brief Description – For PT100 resistance thermometers in 2, 3 or 4wire technology – Can be mounted on symmetrical EN 50 022 DIN rails Temperature – Can be freely programmed using the |
Original | ||||
| mcr-sl-pt100-lp-i | Programmable Loop-Powered Temperature Measuring Transducer for PT100 Sensors MCR-SL-PT100-LP-I 1. Brief Description – For PT100 resistance thermometers in 2, 3 or 4wire technology – Can be mounted on symmetrical EN 50 022 DIN rails Temperature – Can be freely programmed using the |
Original | ||||
| I-6012/6012M 1-channel Isolated Analog Input | I-6012/6012M 1-channel Isolated Analog Input Module Specifications Analog Input 1 differential 16 bits, 10 samples/sec., 12 bits, 100 samples/sec. (optional) Input type mV, V, mA Input range ±150mV, ±500mV, ±1V, ±5V, ±10V, ±20mA Bandwidth 13.1Hz Accuracy |
Original | ||||
| signal converter pt100 | Signal converter PT100 / RTD - signal isolator/converter PT100, 2-/3-Conductor disconnector converter PT100 Output select • 2-way isolation between input/output and power supply • PT100 2-/ 3-conductor • Output can be switched calibrated via DIP-switch |
Original | ||||
| pt100 | PT100 4-fold temperature measurement Beckhoff II/O System PT100 4-fold temperature measurement Technical description Eiserstraße 5 Telephone: 05246/709-0 D-33415 Verl Fax: 05246/70980 Date : 12 March 97 Version : 1.1 Page 1 of 10 PT100 4-fold temperature measurement |
Original | ||||
| pt100 sensors | Programmable Loop-Powered Temperature Measuring Transducer for PT100 Sensors MCR-SL-HT-PT100-I 1. Brief Description – For PT100 resistance thermometers in 2, 3 or 4-wire technology – For installation in Form B connection head ϑ POWER I SL Dimensional drawing for MCR-FL-HT-PT100-I |
Original | ||||
| JTB/TW Temperaturbegrenzer und -wächter | JTB/TW Temperaturbegrenzer und -wächter Temperature limiter and monitor Limiteurs et contrôleurs de température B 70.1140.0 Betriebsanleitung Operating Instructions Notice de mise en service 12.06/00383933 1 2 3 4 5 6 7 Kurzbeschreibung… 4 |
Original | ||||
| Cable Sensor, Pt100/Pt1000 Sensors with 4-wire | Cable Sensor, Pt100/Pt1000 Sensors with 4-wire silicone cable for pockets or tubes 4-wire air sensors Elements in 1/1 DIN B, 1/3 DIN B and 1/6 DIN B The sensors can be used with the CombiTemp, Building Block Temperature Measuring System Description A platinum resistor is built into the temperature sensor. Changes in |
Original | ||||
| pt100 temperature | TE2 - Pt100 Temperature Sensors Case in stainless steel Wetted parts in acid-proof, stainless steel or PEEK Wide range of process connections Pt100 sensors, single or duplex element DIN A or B (1/1 or 1/3) elements Standard or fast response sensor tip Electrical connection M12 or DIN43650 plug |
Original | ||||
| pt100 sensor | Programmable Loop-Powered Temperature Measuring Transducer for PT100 Sensors MCR-SL-HT-PT100-I 1. Brief Description – For PT100 resistance thermometers in 2, 3 or 4-wire technology – For installation in Form B connection head ϑ POWER I SL Dimensional drawing for MCR-FL-HT-PT100-I |
Original | ||||
| CombiTemp TCR6 Standard-RTD-Temperatursensor | CombiTemp TCR6 Standard-RTD-Temperatursensor Leistungsmerkmale Sensor und Anschluss aus Edelstahl AISI 316L Gehäuse DIN Form B Robustes Design Anwendungsbereiche Industrielle Anwendungen mit Wassersysteme Tanks und Behälter industriellen Prozessanschlüssen |
Original | ||||