PT100 TRA Search Results
PT100 TRA Price and Stock
Samtec Inc
Samtec Inc UMPT-10-01-T-RA-WT-TRPower to the Board 2.00 mm mPOWER Ultra Micro Power Terminal |
|||||||||||
| Distributors | Part | Package | Stock | Lead Time | Min Order Qty | Price | Buy | ||||
|
UMPT-10-01-T-RA-WT-TR | 125 |
|
Buy Now | |||||||
Samtec Inc MPPT-10-01-02-T-RA-SDPower to the Board 5.00 mm PowerStrip/30 A Hermaphroditic Terminal/Socket Strip |
|||||||||||
| Distributors | Part | Package | Stock | Lead Time | Min Order Qty | Price | Buy | ||||
|
MPPT-10-01-02-T-RA-SD |
|
Get Quote | ||||||||
Samtec Inc UMPT-10-01-T-RA-WT-FRPower to the Board |
|||||||||||
| Distributors | Part | Package | Stock | Lead Time | Min Order Qty | Price | Buy | ||||
|
UMPT-10-01-T-RA-WT-FR |
|
Get Quote | ||||||||
Documents mentioning PT100 TRA
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| pt100 sensors | Programmable Loop-Powered Temperature Measuring Transducer for PT100 Sensors MCR-SL-HT-PT100-I 1. Brief Description – For PT100 resistance thermometers in 2, 3 or 4-wire technology – For installation in Form B connection head ϑ POWER I SL Dimensional drawing for MCR-FL-HT-PT100-I |
Original | ||||
| pt100 sensor | Programmable Loop-Powered Temperature Measuring Transducer for PT100 Sensors MCR-SL-HT-PT100-I 1. Brief Description – For PT100 resistance thermometers in 2, 3 or 4-wire technology – For installation in Form B connection head ϑ POWER I SL Dimensional drawing for MCR-FL-HT-PT100-I |
Original | ||||
| mcr-sl-pt100 | Temperature Measuring Transducer for PT100 MCR-SL-PT100-…-DC-24 1. Description MCR-SL-PT100 temperature measuring transducers convert the measured values of the PT100 sensor (IEC rigid751/EN 60751) into electrically standardized analog signals. The sensor is supplied from the module with a low |
Original | ||||
| signal conditioning | Product catalogue | Electronics | Analogue signal conditioning | Temperature RTD - signal isolator/converter | PT100, 2-/3-/4-conductor temperature transducer | MCZ PT100/3 CLP General ordering data Order No. Part designation Version EAN Qty. 8473010000 MCZ PT100/3 CLP 0…200C |
Original | ||||
| mcr-sl-pt100-ui | MINI MCR-SL-PT100-UI… Configurable Temperature Transducer for PT100 Data Sheet 11/2004 Product Description Features MINI MCR-SL-PT100-UI… is a configurable 3-way isolated temperature measuring transducer. It is suitable for the connection of PT100 resistance thermometers in acc. with IEC 60751 in 2, 3 and 4-conductor |
Original | ||||
| rtd signal conditioner | cores cores Analog measurement technology RTD Signal Conditioner for Pt100 cores Pt100 Dimensions (mm) W x H x D 19 x 75 x 110.8 Approvals: L cores Pt100 with alarm output , CSA Approvals: L , CSA Description RTD Signal Conditioner for Pt100 Type Part no. |
Original | ||||
| pt100 | Product catalogue | Electronics | Analogue signal conditioning | Temperature RTD - signal isolator/converter | PT100, 2-/3-/4-conductor temperature transducer | MCZ PT100/3 CLP General ordering data Order No. Part designation Version EAN Qty. 8473000000 MCZ PT100/3 CLP -50C…+150C |
Original | ||||
| signal isolator | Product catalogue | Electronics | Analogue signal conditioning | Temperature RTD - signal isolator/converter | PT100, 2-/3-/4-conductor temperature transducer | MCZ PT100/3 CLP General ordering data Order No. Part designation Version EAN Qty. 8473020000 MCZ PT100/3 CLP 0…300C |
Original | ||||
| afficheur | CODIX 531 für Widerstands-Thermometer Pt100, Ni100 deutsch Digitalanzeige for resitance thermometers Pt100, Ni100 english Digital display Afficheur digital Pt100, Ni100 français pour thermomètres à résistance Visualizador digital Visualizzatore digitale |
Original | ||||
| mcr-sl-pt100-lp-i | Programmable Loop-Powered Temperature Measuring Transducer for PT100 Sensors MCR-SL-PT100-LP-I 1. Brief Description – For PT100 resistance thermometers in 2, 3 or 4wire technology – Can be mounted on symmetrical EN 50 022 DIN rails Temperature – Can be freely programmed using the |
Original | ||||
| pt100 sensor | Programmable Loop-Powered Temperature Measuring Transducer for PT100 Sensors MCR-SL-PT100-LP-I 1. Brief Description – For PT100 resistance thermometers in 2, 3 or 4wire technology – Can be mounted on symmetrical EN 50 022 DIN rails Temperature – Can be freely programmed using the |
Original | ||||
| pt100 | PT100 4-fold temperature measurement Beckhoff II/O System PT100 4-fold temperature measurement Technical description Eiserstraße 5 Telephone: 05246/709-0 D-33415 Verl Fax: 05246/70980 Date : 12 March 97 Version : 1.1 Page 1 of 10 PT100 4-fold temperature measurement |
Original | ||||
| pt100 sensors | G2TI1 PT100 Temperature measurement with PT100 sensors (2- and 3-wire connection) Sensor failure detection Reinforced insulation of the input circuit Measured value transmitting via standard bus Modular monitoring system Width 22.5mm Industrial design Technical data |
Original | ||||
| mcr-pt100-i-nc | Extract from the online catalog MCR-PT100-I-NC Order No.: 2810421 The illustration shows version MCR-PT100-I-DC http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2810421 Pt 100 temperature transducer, configurable via DIP switch, selection |
Original | ||||
|
|
||||||
| mcr-pt100-i | Extract from the online catalog MCR-PT100-U-NC Order No.: 2810418 The illustration shows version MCR-PT100-I-DC http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2810418 Pt 100 temperature transducer, configurable via DIP switch, selection |
Original | ||||
| Maxim > App Notes > Automotive Measurement | Maxim > App Notes > Automotive Measurement circuits Temperature sensors and thermal management Keywords: temperature sensor, RTD, platinum Feb 21, 2005 APPLICATION NOTE 3450 Positive analog feedback compensates PT100 transducer Abstract: This article reviews the basic characteristics of common temperature sensors, describes the RTD PT100 temperature |
Original | ||||
| dvp04pt-h2 | 2007-01-10 Control Registers 1.3 External Wiring 1mA PT100 Shielding cable *1 5011651800-P2E0 http://www.delta.com.tw/industrialautomation/ DVP04PT-H2 CH1 CR RS-485 # Parameter Latched address L+ LI- Temperature Measurement Module FG Instruction Sheet PT100 |
Original | ||||
| FR NOTICE D’INSTRUCTIONS - AT42 thermomètre sonde | FR NOTICE D’INSTRUCTIONS - AT42 thermomètre sonde platine Pt100 Entrée sonde platine Pt100 Résolution 1 °C ou 0,1 °C Affichage 10000 points 2 seuils d'alarme Valeur moyenne Sortie analogique ajustable 4-20 mA (0-20 mA) ou 0-10 V L’ indicateur AT42 est un thermomètre numérique dédicacé aux entrées sondes platines Pt100 équipé de 2 |
Original | ||||
| rtd pt100 | Maxim > App Notes > AUTOMOTIVE MEASUREMENT CIRCUITS TEMPERATURE SENSORS and THERMAL MANAGEMENT Keywords: temperature sensor, RTD, platinum Feb 21, 2005 APPLICATION NOTE 3450 Positive Analog Feedback Compensates PT100 Transducer Abstract: This article reviews the basic characteristics of common temperature sensors, describes the RTD PT100 |
Original | ||||
| thermoelement | Produktübersicht Signalwandler für analoge und digitale Signale PT100-Sensoren, Thermoelemente Signalwandler ohne Spannungsversorgung Seite 6-8/4 Signalwandler mit beidseitiger Spannungsversorgung Seite 6-8/7 Signalwandler für Temperatursensor PT100 Seite 6-8/21 … 23 |
Original | ||||
| lkm 103 | Components and accessories Transmitter Transmitter LKM 103 u + - Æ 44 mm 26,5mm high In-Head Transmitter LKM 103 Pt100/Pt1000, B-head, 4..20mA, 24V supply voltage The LKM 103 is an analogue transducer for Pt100/Pt1000 sensors acc. DIN EN 60751. The temperature sensitive resistance |
Original | ||||
| Temperature Measurement © Siemens AG 2012 | Temperature Measurement © Siemens AG 2012 Transmitters for mounting in sensor head SITRANS TH100 two-wire system (Pt100) ■ Overview ■ Application Used in conjunction with Pt100 resistance thermometers, the SITRANS TH100 transmitters are ideal for measuring temperatures in all industries. Due to its compact size it can be installed |
Original | ||||