PT100 RANGE Search Results
PT100 RANGE Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| SF-QXP85B402D-000 | Amphenol Cables on Demand | Amphenol SF-QXP85B402D-000 QSFP28 100GBASE-SR Short-Range 850nm Multi-Mode Optical Transceiver Module (MTP/MPO Connector) by Amphenol XGIGA [QXP85B402D] | |||
| SF-XP85B102DX-000 | Amphenol Cables on Demand | Amphenol SF-XP85B102DX-000 SFP28 25GBASE-SR Short-Range 850nm Multi-Mode Optical Transceiver Module (Duplex LC Connector) by Amphenol XGIGA [XP85B102DX] | |||
| LD09S24A4PA00LF | Amphenol Communications Solutions | D-Subminiature Economy range, Input Output Connectors, Signal 9 way Socket Straight Solder, 50 cycles, Std hole, 1.6mm PCB thickness. | |||
| LD09P24B4PA00LF | Amphenol Communications Solutions | D-Subminiature Economy range, Input Output Connectors, Signal 9 way Pin Straight Solder, 50 cycles, Std hole, 2.4mm PCB thickness. | |||
| LD09S24A4PX00LF | Amphenol Communications Solutions | D-Subminiature Economy range, Input Output Connectors, Signal 9 way Socket Straight Solder, 50 cycles, Threaded insert UNC 4-40, 1.6mm PCB thickness. |
Documents mentioning PT100 RANGE
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| signal converter pt100 | Signal converter PT100 / RTD - signal isolator/converter PT100, 2-/3-Conductor disconnector converter PT100 Output select • 2-way isolation between input/output and power supply • PT100 2-/ 3-conductor • Output can be switched calibrated via DIP-switch |
Original | ||||
| rtd signal conditioner | cores cores Analog measurement technology RTD Signal Conditioner for Pt100 cores Pt100 Dimensions (mm) W x H x D 19 x 75 x 110.8 Approvals: L cores Pt100 with alarm output , CSA Approvals: L , CSA Description RTD Signal Conditioner for Pt100 Type Part no. |
Original | ||||
| pt100 sensors | Programmable Loop-Powered Temperature Measuring Transducer for PT100 Sensors MCR-SL-HT-PT100-I 1. Brief Description – For PT100 resistance thermometers in 2, 3 or 4-wire technology – For installation in Form B connection head ϑ POWER I SL Dimensional drawing for MCR-FL-HT-PT100-I |
Original | ||||
| pt100 sensor | Programmable Loop-Powered Temperature Measuring Transducer for PT100 Sensors MCR-SL-HT-PT100-I 1. Brief Description – For PT100 resistance thermometers in 2, 3 or 4-wire technology – For installation in Form B connection head ϑ POWER I SL Dimensional drawing for MCR-FL-HT-PT100-I |
Original | ||||
| mcr-sl-pt100 | Temperature Measuring Transducer for PT100 MCR-SL-PT100-…-DC-24 1. Description MCR-SL-PT100 temperature measuring transducers convert the measured values of the PT100 sensor (IEC rigid751/EN 60751) into electrically standardized analog signals. The sensor is supplied from the module with a low |
Original | ||||
| afficheur | CODIX 531 für Widerstands-Thermometer Pt100, Ni100 deutsch Digitalanzeige for resitance thermometers Pt100, Ni100 english Digital display Afficheur digital Pt100, Ni100 français pour thermomètres à résistance Visualizador digital Visualizzatore digitale |
Original | ||||
| signal conditioning | Product catalogue | Electronics | Analogue signal conditioning | Temperature RTD - signal isolator/converter | PT100, 2-/3-/4-conductor temperature transducer | MCZ PT100/3 CLP General ordering data Order No. Part designation Version EAN Qty. 8473010000 MCZ PT100/3 CLP 0…200C |
Original | ||||
| mcr-sl-pt100-ui | MINI MCR-SL-PT100-UI… Configurable Temperature Transducer for PT100 Data Sheet 11/2004 Product Description Features MINI MCR-SL-PT100-UI… is a configurable 3-way isolated temperature measuring transducer. It is suitable for the connection of PT100 resistance thermometers in acc. with IEC 60751 in 2, 3 and 4-conductor |
Original | ||||
| pt100 | Product catalogue | Electronics | Analogue signal conditioning | Temperature RTD - signal isolator/converter | PT100, 2-/3-/4-conductor temperature transducer | MCZ PT100/3 CLP General ordering data Order No. Part designation Version EAN Qty. 8473000000 MCZ PT100/3 CLP -50C…+150C |
Original | ||||
| pt100 | Pt100 Platinum Sensing Resistors Pt100 Elements, Thin Film (100 Ohm) • Pt100 elements to IEC 751 Class A & B For use from –50oC to +550oC Thin film construction Suits surface & immersion applications where protected Vibration resistant |
Original | ||||
| pt100 | NEW PRODUCTS 2009 Pt100 Platinum Thin Film Sensing Resistors Pt100 Elements, Thin Film (100 Ohm) Pt100 elements to IEC 751 Class A & B For use from –50oC to +500oC Thin film construction Suits surface & immersion applications where protected |
Original | ||||
| signal isolator | Product catalogue | Electronics | Analogue signal conditioning | Temperature RTD - signal isolator/converter | PT100, 2-/3-/4-conductor temperature transducer | MCZ PT100/3 CLP General ordering data Order No. Part designation Version EAN Qty. 8473020000 MCZ PT100/3 CLP 0…300C |
Original | ||||
| pt100 | PT100 4-fold temperature measurement Beckhoff II/O System PT100 4-fold temperature measurement Technical description Eiserstraße 5 Telephone: 05246/709-0 D-33415 Verl Fax: 05246/70980 Date : 12 March 97 Version : 1.1 Page 1 of 10 PT100 4-fold temperature measurement |
Original | ||||
| mcr-sl-pt100-lp-i | Programmable Loop-Powered Temperature Measuring Transducer for PT100 Sensors MCR-SL-PT100-LP-I 1. Brief Description – For PT100 resistance thermometers in 2, 3 or 4wire technology – Can be mounted on symmetrical EN 50 022 DIN rails Temperature – Can be freely programmed using the |
Original | ||||
|
|
||||||
| pt100 sensor | Programmable Loop-Powered Temperature Measuring Transducer for PT100 Sensors MCR-SL-PT100-LP-I 1. Brief Description – For PT100 resistance thermometers in 2, 3 or 4wire technology – Can be mounted on symmetrical EN 50 022 DIN rails Temperature – Can be freely programmed using the |
Original | ||||
| temperature controller | TEMPERATURE CONTROLLER MOUNTED ON A 35 mm RAIL RE60 TYPE Current flowing through Pt100 < 220 mA Measurement time 0.5 s Detection of error in the measuring circuit: - thermocouple, Pt100 overflow of the measuring range Kinds of outputs: - relay voltageless make contacts |
Original | ||||
| pt100 sensors | G2TI1 PT100 Temperature measurement with PT100 sensors (2- and 3-wire connection) Sensor failure detection Reinforced insulation of the input circuit Measured value transmitting via standard bus Modular monitoring system Width 22.5mm Industrial design Technical data |
Original | ||||
| dvp04pt-h2 | 2007-01-10 Control Registers 1.3 External Wiring 1mA PT100 Shielding cable *1 5011651800-P2E0 http://www.delta.com.tw/industrialautomation/ DVP04PT-H2 CH1 CR RS-485 # Parameter Latched address L+ LI- Temperature Measurement Module FG Instruction Sheet PT100 |
Original | ||||
| FR NOTICE D’INSTRUCTIONS - AT42 thermomètre sonde | FR NOTICE D’INSTRUCTIONS - AT42 thermomètre sonde platine Pt100 Entrée sonde platine Pt100 Résolution 1 °C ou 0,1 °C Affichage 10000 points 2 seuils d'alarme Valeur moyenne Sortie analogique ajustable 4-20 mA (0-20 mA) ou 0-10 V L’ indicateur AT42 est un thermomètre numérique dédicacé aux entrées sondes platines Pt100 équipé de 2 |
Original | ||||
| rtd input | 4-channel Isolated RTD Input Module Specifications Analog Input 4 16 bits, 10 samples/sec., 12 bits, 100 samples/sec. (optional) Input type Pt and Ni RTD RTD type and Type Range ∂ temperature ranges Pt100 -100˚C ~ 100˚C 0.00385 Pt100 0˚C ~ 100˚C 0.00385 |
Original | ||||
| pt100 temperature | TE2 - Pt100 Temperature Sensors Case in stainless steel Wetted parts in acid-proof, stainless steel or PEEK Wide range of process connections Pt100 sensors, single or duplex element DIN A or B (1/1 or 1/3) elements Standard or fast response sensor tip Electrical connection M12 or DIN43650 plug |
Original | ||||
| E031030 000727 Process module analog input PMAI | E031030 000727 Process module analog input PMAI PT100 -70…220°C/ 0…100°C Operation Design Converts measuring values of up to 4 temperature sensors PT100. The unit also offers the following functions: - Linearizing of values - Check on wire cracks - Measuring error compensation |
Original | ||||