| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| pt100 temperature | TE2 - Pt100 Temperature Sensors Case in stainless steel Wetted parts in acid-proof, stainless steel or PEEK Wide range of process connections Pt100 sensors, single or duplex element DIN A or B (1/1 or 1/3) elements Standard or fast response sensor tip Electrical connection M12 or DIN43650 plug |
Original | ||||
| MODEL CONFIGURATION PXZ SERIES 1 P X Z Operation | MODEL CONFIGURATION PXZ SERIES 1 P X Z Operation Manual PID Autotune Controllers Featuring Fuzzy Logic Front panel size 1/16 DIN 1/8 DIN 72mm 1/4 DIN Code 4 5 7 9 Kinds of input Thermocouple (°C) Thermocouple (°F) RTD/Pt100 (°C) RTD/Pt100 (°F) 4-20mA DC, 1-5V DC |
Original | ||||
| DIGITAL TEMPERATURE & PROCESS CONTROLLERS + 16 17 | DIGITAL TEMPERATURE & PROCESS CONTROLLERS + 16 17 18 4 5 6 7 8 9 Output 2 (W/Z types) Output 4 (Z types) 10 11 12 13 14 15 Output 3 (Z types) 16 17 7 18 - 2 4 3 6 Supply 7 8 9 7 - Digital I/P 5 PT100 1 Output 1 8 9 + T/C 8 9 10V O/P V/A PRG mute PT100 12-24Vac/dc +/- 10% 110/230V with transformers |
Original | ||||
| pt100 | DIGITAL TEMPERATURE & PROCESS CONTROLLERS + 16 17 18 4 5 6 7 8 9 Output 2 (W/Z types) Output 4 (Z types) 10 11 12 13 14 15 Output 3 (Z types) 16 17 7 18 - 2 4 3 6 Supply 7 8 9 7 - Digital I/P 5 PT100 1 Output 1 8 9 + T/C 8 9 10V O/P V/A PRG mute PT100 12-24Vac/dc +/- 10% 110/230V with transformers |
Original | ||||
| pt100 sensor | 1 797 FT-TP/100 FT-TP/400 Immersion temperature sensor for HVAC systems Immersion temperature sensor for heating, ventilation and air conditioning systems • For use with controllers with Pt100 sensor inputs • In conjunction with MULTIREG and INTEGRAL RS. |
Original | ||||
| LIMO MB free beam Series HIGH-POWER DIODE LASER • | LIMO MB free beam Series HIGH-POWER DIODE LASER • High brightness laser for medical, pump and material processing applications Hermetically sealed laser head in potential- free housing Compact dimensions 2 temperature sensors (NTC/PT100) Optical data |
Original | ||||
| sem1503p | INDEX SEM1503P & SEM1504P DIN Rail Mounted Pt100 Transmitter Status Instruments Ltd, Green Lane Business Park, Tewkesbury, Glos. GL20 8DE Tel: +44 (0)1684 296818 Email: sales@status.co.uk Fax: +44 (0)1684 293746 Web: www.status.co.uk 52-214-2411-01 Issue: Web 1503/4 |
Original | ||||
| laser head | LIMO AV5 Series (pump) HIGH-POWER DIODE LASER • Optical data High brightness laser for pump applications Hermetically sealed laser head in potential-free housing SMA905 / LD80 Plug & Play connector for optical fibres Compact dimensions Dual temperature sensor (NTC/PT100) |
Original | ||||
| ab-5429 | AB-5429 Specifications/Instructions Pipe Insertion Sensor TY783 General The pipe insertion temperature sensor (TY783) has the output characteristics of a Pt100 platinum resistance (JIS C1604A) and is used for temperature reading, control and recording of a variety of liquids inside pipes, tanks or heat |
Original | ||||
| sma905 | LIMO FP Series (pump) HIGH-POWER DIODE LASER • Optical data High brightness laser for pump applications Hermetically sealed laser head in potential-free housing SMA905 Plug & Play connector for optical fibres Compact dimensions Dual temperature sensor (NTC/PT100) |
Original | ||||
| pt100 | CombiTemp TFRH TM Hygienic – RTD temperature sensor Main features Pt100 sensor element, 2- or 4-wire Built in graphical display, CombiViewTM DFON optional Head mounted 4…20 mA transmitter, FlexTop type 22xx HART®, PA ATEX |
Original | ||||
| DATA SHEET 1033 m SPECIFICATION Input type 4-20mA | DATA SHEET 1033 m SPECIFICATION Input type 4-20mA or 0-10V PT100 be used e.g. 0-20mA other inputs may Number of Inputs 1 Operating M ode Step Level Output type Relay or optoisolated transistor 110.0 mm 55.0mm Configuration Normally Open Number of Outputs 4 |
OCR Scan | ||||
| CombiTemp TFRN TM Industrial – RTD temperature | CombiTemp TFRN TM Industrial – RTD temperature sensor Main features Pt100 sensor element, ATEX Programmable by touch screen Easy and full programmable 2- or 4-wire HART®, PA Built in graphical display, CombiViewTM DFON optional |
Original | ||||
| 2 © Siemens AG 2015 Temperature Measurement 2/2 | 2 © Siemens AG 2015 Temperature Measurement 2/2 2/7 2/11 2/18 2/25 2/31 2/38 2/45 Product overview Transmitters for mounting in sensor head SITRANS TH100 two-wire system (Pt100) SITRANS TH200 two-wire system universal SITRANS TH300 two-wire system universal, HART |
Original | ||||
|
|
||||||
| th300 | 2 © Siemens AG 2013 Temperature Measurement 2/2 Product overview 2/124 2/7 2/11 2/18 2/25 2/31 2/38 2/45 2/57 2/62 2/70 Transmitters for mounting in sensor head SITRANS TH100 two-wire system (Pt100) SITRANS TH200 two-wire system universal SITRANS TH300 two-wire system |
Original | ||||
| Cable Sensor, Pt100/Pt1000 Sensors with 4-wire | Cable Sensor, Pt100/Pt1000 Sensors with 4-wire silicone cable for pockets or tubes 4-wire air sensors Elements in 1/1 DIN B, 1/3 DIN B and 1/6 DIN B The sensors can be used with the CombiTemp, Building Block Temperature Measuring System Description A platinum resistor is built into the temperature sensor. Changes in |
Original | ||||
| Electronic Pressure Measurement Panel Mount | Electronic Pressure Measurement Panel Mount Digital Indicator Type DI-15 Datasheet DI-15 Applications n Plant construction n Machine tools n Onboard vehicle displays n General industrial applications Special Features n Multi-function process inputs for standard signals, |
Original | ||||
| Analogue Signal Processing 156 Analogue Signal | Analogue Signal Processing 156 Analogue Signal Processing The real world can be measured in many ways, for example, via temperature, humidity, air pressure and so forth. The parameters of these different physical qualities change continuously. Elements that monitor statuses and changes in statuses of a given environment, must reflect |
Original | ||||
| dipos dipos Measurement and control technology | dipos dipos Measurement and control technology Wieland signal conditioners for measurement and control technology. The basis of modern automation is the preparation and transfer of physical variables such as temperature, pressure, speed or humidity. These variables are |
Original | ||||
| CombiTemp TCR6 Standard RTD temperature sensor | CombiTemp TCR6 Standard RTD temperature sensor Main features Sensor and connection in stainless steel, AISI 316L DIN form B housing Robust design Applications Industrial applications with Water systems Tanks and vessels industrial process connection |
Original | ||||