Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    PT100 PLAT Search Results

    Documents mentioning PT100 PLAT

    Document Partial File Text Tags Type PDF
    pt100
    Pt100 Platinum Sensing Resistors Pt100 Elements, Thin Film (100 Ohm) • Pt100 elements to IEC 751 Class A & B For use from –50oC to +550oC Thin film construction Suits surface & immersion applications where protected Vibration resistant
    Original PDF
    pt100
    NEW PRODUCTS 2009 Pt100 Platinum Thin Film Sensing Resistors Pt100 Elements, Thin Film (100 Ohm)  Pt100 elements to IEC 751 Class A & B For use from –50oC to +500oC Thin film construction Suits surface & immersion applications where protected
    Original PDF
    FR NOTICE D’INSTRUCTIONS - AT42 thermomètre sonde
    FR NOTICE D’INSTRUCTIONS - AT42 thermomètre sonde platine Pt100 Entrée sonde platine Pt100 Résolution 1 °C ou 0,1 °C Affichage 10000 points 2 seuils d'alarme Valeur moyenne Sortie analogique ajustable 4-20 mA (0-20 mA) ou 0-10 V L’ indicateur AT42 est un thermomètre numérique dédicacé aux entrées sondes platines Pt100 équipé de 2
    Original PDF
    pl
    Maxim > App Notes > Automotive Measurement circuits Temperature sensors and thermal management Keywords: temperature sensor, RTD, platinum Feb 21, 2005 APPLICATION NOTE 3450 Positive analog feedback compensates PT100 transducer Abstract: This article reviews the basic characteristics of common temperature sensors, describes the RTD PT100 temperature
    Original PDF
    dvp04pt-h2
    2007-01-10 Control Registers 1.3 External Wiring 1mA PT100 Shielding cable *1 5011651800-P2E0 http://www.delta.com.tw/industrialautomation/ DVP04PT-H2 CH1 CR RS-485 # Parameter Latched address L+ LI- Temperature Measurement Module FG Instruction Sheet PT100
    Original PDF
    rtd pt100
    Maxim > App Notes > AUTOMOTIVE MEASUREMENT CIRCUITS TEMPERATURE SENSORS and THERMAL MANAGEMENT Keywords: temperature sensor, RTD, platinum Feb 21, 2005 APPLICATION NOTE 3450 Positive Analog Feedback Compensates PT100 Transducer Abstract: This article reviews the basic characteristics of common temperature sensors, describes the RTD PT100
    Original PDF
    pt100 temperature
    TE2 - Pt100 Temperature Sensors Case in stainless steel Wetted parts in acid-proof, stainless steel or PEEK Wide range of process connections Pt100 sensors, single or duplex element DIN A or B (1/1 or 1/3) elements Standard or fast response sensor tip Electrical connection M12 or DIN43650 plug
    Original PDF
    sonde pt100
    AT44 Indicateur conditionneur pour sonde platine PT100 Affichage 4 500 points Entrée sonde PT100 Résolution 1°C ou 0,1°C Valeur moyenne Gamme -200°C à +450°C Conformes aux exigences de compatibilitélectromagnétique CEM DIRECTIVE 89/336/ . L’ indicateur AT44 est un indicateur numérique dédicacé aux entrées
    Original PDF
    4082
    External Wiring PT100 PT100 Shielding cable *1 CH1 L+ LIFG 1mA R Error status CR#30: Error status (see the table below): AG *2 *3 System grounding Earth (100 or less) ╳ H’4082 Register for storing all error status. See the table of error status for more information.
    Original PDF
    RAD-PT100-4-IFS I/O extension module, 4
    RAD-PT100-4-IFS I/O extension module, 4 temperature inputs (Pt 100) Data sheet 105366_en_00 1 © PHOENIX CONTACT 2013-12-06 Description The RAD-PT100-4-IFS I/O extension module can be used in conjunction with Radioline wireless modules and other Interface system (IFS) master devices. In a station structure,
    Original PDF
    hty79x3
    AB-5963 Specifications/Instructions Insertion Dewpoint Temperature Sensor HTY79X3 / HY79X3 General Insertion dewpoint temperature sensor HTY79X3 series uses a Pt100 platinum film temperature sensing element and a polymer capacitive film humidity sensing element
    Original PDF
    humidity sensor
    AB-5967 Specifications/Instructions Insertion Temperature/Humidity Sensor HTY78X6/ HY78X6 General Uses a Pt100 platinum film temperature sensing element and a polymer capacitive film humidity sensing element (FP3 specially developed by Yamatake) which ensures
    Original PDF
    iec 60751
    Maxim > Design Support > Technical Documents > App Notes > APP 4875 Keywords: Platinum Resistance Temperature Detectors, IEC 60751, Precision Delta Sigma ADCs,PT100, PT1000, MAX11200 ADC, measures temperature ratiometrically, temperature errors analysis, Linearization, measurement resolution, RT, PRTD
    Original PDF
    humidity sensor
    AB-5961 Specifications/Instructions Insertion Temperature/Humidity Sensor HTY78X3/ TY78X3/ HY78X3 General Insertion temperature/humidity sensor HTY78X3 series uses a Pt100 platinum film temperature sensing element and a polymer capacitive film humidity sensing element
    Original PDF
    humidity sensor
    AB-5959 Specifications/Instructions Neosensor / Neomini Sensor Room Temperature / Humidity Sensor HTY70X3 / TY70X3 / HY70X3 General Room temperature/humidity sensor HTY70X3 series uses a Pt100 platinum film temperature sensing element and a polymer capacitive film humidity sensing element (FP3
    Original PDF
    e
    Data Sheet DS/TTH200-EN Head mounted Temperature Transmitter TTH200 HART, Pt100 (RTD), thermocouples, Electrical isolation Input - Resistance thermometer - Thermocouples - Resistance-type transmitters - Voltages, mV voltages Output - 4… 20 mA, HART Measurement deviation
    Original PDF
    pt100 platinum resistance temperature detector
    PT100 Platinum Resistance Temperature Detector 22810 “StikonTM” mounting methods. • 3 and 4 terminal versions • 3850 ppm/°C Model 22810 is a polyimide insulated surface sensor designed to provide a practical method for measuring surface temperature. These sensors
    Original PDF
    hsrtd-3-100-a-1m
    DATENBLATT HSRTD HSRTD Sterilisierbare, voll PFA-gekaspelte Pt100-Fühler Für korrosive Umgebungen und beengte Platzbedingungen Nenndurchmesser 2,1 mm HSRTD-3-100-A-1M Vergrößerte Abbildung 0,14 mm2 der Spitze vernickelte Kupferlitze, PFA-isoliert, Standardlänge 1 m
    Original PDF
    hty70
    AB-5965 Specifications/Instructions Ceiling Mounted Sensor HTY7033/ TY7033 General The HTY7033 Ceiling Mounted Sensor uses a Pt100 platinum film temperature sensing element and a polymer capacitive film humidity sensing element (FP3 specially developed by Yamatake) which ensures highly accurate
    Original PDF
    Temperature Indicator K3HB-H New High-speed,
    Temperature Indicator K3HB-H New High-speed, High-precision Temperature Indicator • Capable of high-speed sampling at 50 times per second (20 ms). • High-resolution of 0.01°C with platinum-resistance thermometer Pt100 input. Thermocouple sensor inputs also support a resolution of
    Original PDF
    ab-5429
    AB-5429 Specifications/Instructions Pipe Insertion Sensor TY783 General The pipe insertion temperature sensor (TY783) has the output characteristics of a Pt100 platinum resistance (JIS C1604A) and is used for temperature reading, control and recording of a variety of liquids inside pipes, tanks or heat
    Original PDF
    sem203
    INDEX SEM203 SERIES Push Button Pt100 & Thermocouple In Head Temperature Transmitter Status Instruments Ltd, Green Lane Business Park, Tewkesbury, Glos. GL20 8DE Tel: +44 (0)1684 296818 Email: sales@status.co.uk Fax: +44 (0)1684 293746 Web: www.status.co.uk
    Original PDF
    AT44 Indicador condicionador para sonda platino
    AT44 Indicador condicionador para sonda platino PT 100 Indicación 4.500 puntos Entrada sonda PT100 Resolución 1°C ó 0,1°C Valor medio Escala de -200°C a +450°C Conforme a las exigencias de compatibilidad electromagnética , normas EN 50081 y 50082 (DIRECTIVA
    Original PDF
    uniflex ci
    v v UNIFLEX CI/CB PMA Universal Transmitter Pt100,Thermocouple, RTD, Potentiometer,Voltage, Current Temperature linear or linear to specification Special functions Setting via front panel keys or PC Comprehensive galvanical isolation CE tested to NAMUR and EN
    Original PDF
    Temperature Indicator K3HB-H CSM_K3HB-H_DS_E_7_1
    Temperature Indicator K3HB-H CSM_K3HB-H_DS_E_7_1 New High-speed, High-precision Temperature Indicator • Capable of high-speed sampling at 50 times per second (20 ms). • High-resolution of 0.01°C with platinum-resistance thermometer Pt100 input. Thermocouple sensor inputs also support a resolution of
    Original PDF