PT100 CALIBR Search Results
PT100 CALIBR Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| TLC4502AMJGB | Texas Instruments | Advanced,Self-Calibrating, Precision, Dual Operational Amplifier 8-CDIP -55 to 125 |
|
|
|
| TLC4502ID | Texas Instruments | Advanced LinEPIC Self-Calibrating Precision Dual Operational Amplifier 8-SOIC -40 to 125 |
|
|
|
| TLC4502ACDR | Texas Instruments | Advanced,Self-Calibrating, Precision, Dual Operational Amplifier 8-SOIC 0 to 70 |
|
|
|
| TLC4502CDR | Texas Instruments | Advanced LinEPIC Self-Calibrating Precision Dual Operational Amplifier 8-SOIC 0 to 70 |
|
|
|
| TLC4502ACD | Texas Instruments | Advanced,Self-Calibrating, Precision, Dual Operational Amplifier 8-SOIC 0 to 70 |
|
|
Documents mentioning PT100 CALIBR
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| signal converter pt100 | Signal converter PT100 / RTD - signal isolator/converter PT100, 2-/3-Conductor disconnector converter PT100 Output select • 2-way isolation between input/output and power supply • PT100 2-/ 3-conductor • Output can be switched calibrated via DIP-switch |
Original | ||||
| mcr-sl-pt100 | Temperature Measuring Transducer for PT100 MCR-SL-PT100-…-DC-24 1. Description MCR-SL-PT100 temperature measuring transducers convert the measured values of the PT100 sensor (IEC rigid751/EN 60751) into electrically standardized analog signals. The sensor is supplied from the module with a low |
Original | ||||
| FR NOTICE D’INSTRUCTIONS - AT42 thermomètre sonde | FR NOTICE D’INSTRUCTIONS - AT42 thermomètre sonde platine Pt100 Entrée sonde platine Pt100 Résolution 1 °C ou 0,1 °C Affichage 10000 points 2 seuils d'alarme Valeur moyenne Sortie analogique ajustable 4-20 mA (0-20 mA) ou 0-10 V L’ indicateur AT42 est un thermomètre numérique dédicacé aux entrées sondes platines Pt100 équipé de 2 |
Original | ||||
| Maxim > App Notes > Automotive Measurement | Maxim > App Notes > Automotive Measurement circuits Temperature sensors and thermal management Keywords: temperature sensor, RTD, platinum Feb 21, 2005 APPLICATION NOTE 3450 Positive analog feedback compensates PT100 transducer Abstract: This article reviews the basic characteristics of common temperature sensors, describes the RTD PT100 temperature |
Original | ||||
| rtd pt100 | Maxim > App Notes > AUTOMOTIVE MEASUREMENT CIRCUITS TEMPERATURE SENSORS and THERMAL MANAGEMENT Keywords: temperature sensor, RTD, platinum Feb 21, 2005 APPLICATION NOTE 3450 Positive Analog Feedback Compensates PT100 Transducer Abstract: This article reviews the basic characteristics of common temperature sensors, describes the RTD PT100 |
Original | ||||
| pt100 temperature | TE2 - Pt100 Temperature Sensors Case in stainless steel Wetted parts in acid-proof, stainless steel or PEEK Wide range of process connections Pt100 sensors, single or duplex element DIN A or B (1/1 or 1/3) elements Standard or fast response sensor tip Electrical connection M12 or DIN43650 plug |
Original | ||||
| MODEL CONFIGURATION PXZ SERIES 1 P X Z Operation | MODEL CONFIGURATION PXZ SERIES 1 P X Z Operation Manual PID Autotune Controllers Featuring Fuzzy Logic Front panel size 1/16 DIN 1/8 DIN 72mm 1/4 DIN Code 4 5 7 9 Kinds of input Thermocouple (°C) Thermocouple (°F) RTD/Pt100 (°C) RTD/Pt100 (°F) 4-20mA DC, 1-5V DC |
Original | ||||
| pt100 thermistor | DTM 910 LCD Type Pt100 Temperature Indicator The DTM 910 will give an accurate direct temperature reading in either °C or °F from a 2, 3 or 4 wire Pt100 thermistor*. Simple single step calibration is achieved using a 20-turn potentiometer which allows sensitive adjustment. The meter is housed in a robust carrier which can be bolted in place or panel |
Original | ||||
| pt100 | DIGITAL TEMPERATURE & PROCESS CONTROLLERS + 16 17 18 4 5 6 7 8 9 Output 2 (W/Z types) Output 4 (Z types) 10 11 12 13 14 15 Output 3 (Z types) 16 17 7 18 - 2 4 3 6 Supply 7 8 9 7 - Digital I/P 5 PT100 1 Output 1 8 9 + T/C 8 9 10V O/P V/A PRG mute PT100 12-24Vac/dc +/- 10% 110/230V with transformers |
Original | ||||
| % ! % ! & $ ! " $ % ! ! " " ( % " !! + $ " % " ) | % ! % ! & $ ! " $ % ! ! " " ( % " !! + $ " % " ) %* " ! %% ! # # +% " '+ -. * # " & ( LOW RANGE HIGH RANGE #, % % % + ! ! & ' "% " + -.# UNITS PT100 °F, °C T/C K, J, E, N, T, R, S °F, °C Input @ 4 mA Input @ 20 mA mV mV mA mA $ $ ! (% $ / $ " ! 01 INPUT TYPE |
Original | ||||
| tth200 | Data Sheet DS/TTH200-EN Head mounted Temperature Transmitter TTH200 HART, Pt100 (RTD), thermocouples, Electrical isolation Input - Resistance thermometer - Thermocouples - Resistance-type transmitters - Voltages, mV voltages Output - 4… 20 mA, HART Measurement deviation |
Original | ||||
| hty79x3 | AB-5963 Specifications/Instructions Insertion Dewpoint Temperature Sensor HTY79X3 / HY79X3 General Insertion dewpoint temperature sensor HTY79X3 series uses a Pt100 platinum film temperature sensing element and a polymer capacitive film humidity sensing element |
Original | ||||
| humidity sensor | AB-5967 Specifications/Instructions Insertion Temperature/Humidity Sensor HTY78X6/ HY78X6 General Uses a Pt100 platinum film temperature sensing element and a polymer capacitive film humidity sensing element (FP3 specially developed by Yamatake) which ensures |
Original | ||||
| 8e16a | RTD Simulation Values 8E16A Series • 21 PT100 Simulation values Temperature from -100 to +400°C Ideal for calibration and testing DIN 43760 values Dimensions in mm Specifications: T.C. Tolerance @ 25 °C Full load stability No load stability |
Original | ||||
|
|
||||||
| iec 60751 | Maxim > Design Support > Technical Documents > App Notes > APP 4875 Keywords: Platinum Resistance Temperature Detectors, IEC 60751, Precision Delta Sigma ADCs,PT100, PT1000, MAX11200 ADC, measures temperature ratiometrically, temperature errors analysis, Linearization, measurement resolution, RT, PRTD |
Original | ||||
| humidity sensor | AB-5961 Specifications/Instructions Insertion Temperature/Humidity Sensor HTY78X3/ TY78X3/ HY78X3 General Insertion temperature/humidity sensor HTY78X3 series uses a Pt100 platinum film temperature sensing element and a polymer capacitive film humidity sensing element |
Original | ||||
| 1090 Temperature and Process Calibrator Time | 1090 Temperature and Process Calibrator Time Electronics Calibration, Test & Measurement Measure/Simulate 8 thermocouples Measure/Simulate PT100 ITS 90 standard Measure/Source (uV/mV/mA) Display in °C and °F Automatic CJC - selectable |
Original | ||||
| sem203 | INDEX SEM203 SERIES Push Button Pt100 & Thermocouple In Head Temperature Transmitter Status Instruments Ltd, Green Lane Business Park, Tewkesbury, Glos. GL20 8DE Tel: +44 (0)1684 296818 Email: sales@status.co.uk Fax: +44 (0)1684 293746 Web: www.status.co.uk |
Original | ||||
| 2.0 Push Button PT100 Tx Temperature Transmitter | 2.0 Push Button PT100 Tx Temperature Transmitter RECEIVING AND UNPACKING 3.0 SPECIFICATION @ 20 °C INPUT Sensor Type Sensor Range Sensor Connection Minimum span (see note 1) Linearisation Accuracy (see note 2) Thermal Drift Excitation current Lead Resistance effect |
Original | ||||
| humidity sensor | AB-5959 Specifications/Instructions Neosensor / Neomini Sensor Room Temperature / Humidity Sensor HTY70X3 / TY70X3 / HY70X3 General Room temperature/humidity sensor HTY70X3 series uses a Pt100 platinum film temperature sensing element and a polymer capacitive film humidity sensing element (FP3 |
Original | ||||
| uniflex ci | v v UNIFLEX CI/CB PMA Universal Transmitter Pt100,Thermocouple, RTD, Potentiometer,Voltage, Current Temperature linear or linear to specification Special functions Setting via front panel keys or PC Comprehensive galvanical isolation CE tested to NAMUR and EN |
Original | ||||
| tgp-0104 | *HPLQL 'DWD 6KHHW Tinytag Plus Temperature for PT100 probe TGP-0104 I ssue 9: 27 th February 2003 E&OE Features Memory Size No. of Readings Resolution Trigger Start Delayed Start : : : : : Stop Options : Reading Types : Logging Interval : Offload : Alarms : |
Original | ||||