Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    PT100 2 WIRE SENSOR INTER Search Results

    PT100 2 WIRE SENSOR INTER Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    MP-5XRJ11PPXS-014
    Amphenol Cables on Demand Amphenol MP-5XRJ11PPXS-014 Flat Silver Satin Modular Crossed wiring Cable, RJ11 / RJ11 14ft PDF
    MP-64RJ4528GG-003
    Amphenol Cables on Demand Amphenol MP-64RJ4528GG-003 Slim Category-6 (Thin CAT6) UTP 28-AWG Network Patch Cable (550-MHz) with Snagless RJ45 Connectors - Green 3ft PDF
    MP-64RJ4528GK-014
    Amphenol Cables on Demand Amphenol MP-64RJ4528GK-014 Slim Category-6 (Thin CAT6) UTP 28-AWG Network Patch Cable (550-MHz) with Snagless RJ45 Connectors - Black 14ft PDF
    MP-64RJ4528GW-007
    Amphenol Cables on Demand Amphenol MP-64RJ4528GW-007 Slim Category-6 (Thin CAT6) UTP 28-AWG Network Patch Cable (550-MHz) with Snagless RJ45 Connectors - White 7ft PDF
    MP-6A28GNSBLK-007
    Amphenol Cables on Demand Amphenol MP-6A28GNSBLK-007 Slim Category-6a (Thin CAT6a) UTP 28-AWG Network Patch Cable (650-MHz) with Snagless RJ45 Connectors - Black 7ft PDF

    Documents mentioning PT100 2 WIRE SENSOR INTER

    Document Partial File Text Tags Type PDF
    pt100 sensors
    G2TI1 PT100 Temperature measurement with PT100 sensors (2- and 3-wire connection) Sensor failure detection Reinforced insulation of the input circuit Measured value transmitting via standard bus Modular monitoring system Width 22.5mm Industrial design Technical data
    Original PDF
    FlexTemp 2301 Temperature Transmitter 4…20 mA
    FlexTemp 2301 Temperature Transmitter 4…20 mA transmitter for Pt100 sensors 2-, 3- or 4-wire sensors Accuracy better than 0.25°C Sensor offset correction Automatic/configurable cable resistance compensation (2-wire) Sensor error detection 2-way configuration (Windows)
    Original PDF
    2 © Siemens AG 2015 Temperature Measurement 2/2
    2 © Siemens AG 2015 Temperature Measurement 2/2 2/7 2/11 2/18 2/25 2/31 2/38 2/45 Product overview Transmitters for mounting in sensor head SITRANS TH100 two-wire system (Pt100) SITRANS TH200 two-wire system universal SITRANS TH300 two-wire system universal, HART
    Original PDF
    th300
    2 © Siemens AG 2013 Temperature Measurement 2/2 Product overview 2/124 2/7 2/11 2/18 2/25 2/31 2/38 2/45 2/57 2/62 2/70 Transmitters for mounting in sensor head SITRANS TH100 two-wire system (Pt100) SITRANS TH200 two-wire system universal SITRANS TH300 two-wire system
    Original PDF
    g2tmpt100l20
    G2TMPT100L20 Monitoring relays - GAMMA series Temperature monitoring via Pt100 sensors (2- and 3-wire connection) Multifunction Monitoring of short circuit or line break of sensor line Fault latch Supply voltage selectable via power modules 2 change-over contacts
    Original PDF
    pt100
    CombiTemp TFRH TM Hygienic – RTD temperature sensor Main features „„ Pt100 sensor element, 2- or 4-wire „„ Built in graphical display, ­CombiViewTM DFON optional „„ Head mounted 4…20 mA ­transmitter, FlexTop type 22xx „„ HART®, PA „„ ATEX
    Original PDF
    g2tmpt100l20
    G2TMPT100L20 24-240V Monitoring relays - GAMMA series Temperature monitoring via Pt100 sensors (2- and 3-wire connection) Multifunction Monitoring of short circuit or line break of sensor line Fault latch Zoom voltage 24 to 240V AC/DC 2 change-over contacts
    Original PDF
    CombiTemp TFRN TM Industrial – RTD temperature
    CombiTemp TFRN TM Industrial – RTD temperature sensor Main features „„ Pt100 sensor element, „„ ATEX „„ Programmable by touch screen „„ Easy and full programmable 2- or 4-wire „„ HART®, PA „„ Built in graphical display, ­CombiViewTM DFON optional
    Original PDF
    ricos ricos Distributed I/O Modules PT/TC Modules
    ricos ricos Distributed I/O Modules PT/TC Modules 4 sensor inputs per module, self-setting to PT100/PT1000 sensors for 2-wire, 3-wire and 4-wire connection for thermocouples type J/K Dimensions (mm): W x H x D 69 x 92 x 51 Description Analog module 4 inputs PT 100/1000
    Original PDF
    sensor
    Remote I/O Pt/TC modules ricos • 4 sensor inputs per module self-setting on Pt100 / Pt1000 sensors • For thermocouples type J / K / T • For 2, 3 and 4 wire connection • Electronics can be replaced without disconnection of the wiring Dimensions (mm): W x H x D
    Original PDF
    s6000
    S6000 INTERCHANGEABLE SENSOR MODULE FOR RELATIVE HUMIDITY Main characteristics • Interchangeable without recalibration • Linearised and temperature compensated humidity measurement • Operating range: 0… 100 %rh, -30… +85 °C • Accuracy: ± 2 %rh, ± 0,2 °C
    Original PDF
    102-2012:QuarkCatalogTempNew 8/14/12 7:31 AM Page
    102-2012:QuarkCatalogTempNew 8/14/12 7:31 AM Page 102 Oscilloscopes Accessories USB DrDAQ® Data Logger PicoLog CM3 Current Data Logger POWER ENCLOSURES INTERCONNECT TEST & MEASUREMENT 1 PP706 Whether you are a teacher, student, hobbyist or professional, the USB DrDAQ® Data Logger gives you an inexpensive entry
    Original PDF
    pt100
    HYGROCOR RELATIVE HUMIDITY PROBE FOR OEM APPLICATIONS Main characteristics • Measuring range: 0… 100 %rh, -20…+80 °C • Accuracy: ± 2 %rh, ± 0,2 °C • Output signal: 0… 1V (3 wire), Pt100 Ω 1/3 DIN • Supply voltage: 5…32VDC • Housing protection: IP65
    Original PDF
    mtw 12
    Intelligent interface modules Temperature modules for PT 100 Sensors MTW 12,4 MTW 12,4 2- 3-wire 4-wire Circuit diagram Input E1 PT 100 Output ϑ U ϑ E2 Technical data Supply voltage range Supply current Cable resistance (without PT100) Output signals Tolerance
    Original PDF
    transmicor
    TRANSMICOR T231 SERIES RELATIVE HUMIDITY TRANSMITTER FOR WALL MOUNTING Main characteristics • Measuring range: 0… 100 %rh, -30…+70 °C • Accuracy: ± 2 %rh, ± 0,2 °C • Output signal: 4… 20mA (2 wire), Pt100 Ω 1/3 DIN • Supply voltage: 9…33VDC
    Original PDF
    transmicor t220
    TRANSMICOR T220 SERIES RELATIVE HUMIDITY TRANSMITTER FOR HVAC Main characteristics • Measuring range: 0… 98 %rh, -30… +70 °C • Accuracy: ± 2 %rh, ± 0,2 °C • Output signal: 4… 20mA (2 wire), 0… 1V, 0… 5V, 0… 10V, 0… 20mA (3 wire),
    Original PDF
    transmicor
    TRANSMICOR T233 series low temperature RELATIVE HUMIDITY TRANSMITTER WITH REMOTE PROBE Main characteristics • Measuring range: 0… 100 %rh, -30… +85 °C • Accuracy: ± 2 %rh, ± 0,2 °C • Output signal: 4… 20mA (2 wire), Pt100 Ω 1/3 DIN • Power supply: 9… 33VDC
    Original PDF
    transmicor
    TRANSMICOR T232 Series low temperature RELATIVE HUMIDITY TRANSMITTER DUCT VERSION Main characteristics • Measuring range: 0…100 %rh, -30… +85 °C • Accuracy: ± 2 %rh, ± 0,2 °C • Output signal: 4… 20mA (2 wire), Pt100 Ω 1/3 DIN • Power supply: 9… 33VDC
    Original PDF
    transmicor
    TRANSMICOR T233 series high temperature RELATIVE HUMIDITY TRANSMITTER WITH REMOTE PROBE Main characteristics • Measure range: 0… 100 %rh, -30…+140 °C • Accuracy: ± 2 %rh, ± 0,2 °C • Output signal: 4… 20mA (2 wire), Pt100 Ω 1/3 DIN • Power supply: 9/33VDC
    Original PDF
    TRANSMICOR T243 series low temperature RELATIVE
    TRANSMICOR T243 series low temperature RELATIVE HUMIDITY TRANSMITTER WITH REMOTE CABLE PROBE Main characteristics • Measuring range: 0… 100 %rh, -30… +85 °C • Précision: ± 2 %rh, ± 0,2 °C • Output signal: 4… 20mA, 0… 20mA, 2… 10V
    Original PDF
    Zelio Analog Interface Modules Catalog
    Zelio Analog Interface Modules Catalog 8501CT0502R07/13 2013 Class 8501 Zelio Analog Interface Modules Table of Contents Table of Contents Product Description… 5
    Original PDF
    transmicor
    TRANSMICOR T241 series RELATIVE HUMIDITY TRANSMITTER FOR WALL MOUNTING Main characteristics • Measuring range: 0… 100 %rh, -30…+ 70 °C • Accuracy: ± 2 %rh, ± 0,2 °C • Output signal: 4… 20mA, 0… 20mA, 0… 10V, 2… 10V (selectable with jumper),
    Original PDF